Variation in Pediatric Cervical Spine Computed Tomography Radiation Dose Index

被引:13
作者
Marin, Jennifer R. [1 ,2 ]
Sengupta, Debapriya [3 ]
Bhargavan-Chatfield, Mythreyi [3 ]
Kanal, Kalpana M. [4 ]
Mills, Angela M. [5 ]
Applegate, Kimberly E. [6 ]
机构
[1] Univ Pittsburgh, Sch Med, Dept Pediat, Pittsburgh, PA 15261 USA
[2] Univ Pittsburgh, Sch Med, Dept Emergency Med, Pittsburgh, PA 15261 USA
[3] Amer Coll Radiol, Reston, VA USA
[4] Univ Washington, Sch Med, Dept Radiol, Seattle, WA 98195 USA
[5] Univ Penn, Dept Emergency Med, Perelman Sch Med, Philadelphia, PA 19104 USA
[6] Emory Univ, Sch Med, Dept Radiol & Imaging Sci, Atlanta, GA 30322 USA
关键词
EMERGENCY-DEPARTMENT; CLEARANCE PROTOCOL; IMAGE QUALITY; CT; TRAUMA; VARIABILITY; EXPOSURE; CHILDREN; CHILDHOOD; INJURY;
D O I
10.1111/acem.12822
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: The objective was to evaluate variation in the current estimated radiation dose index for pediatric cervical spine (c-spine) computed tomography (CT) examinations. Methods: This was a retrospective analysis of pediatric (age younger than 19 years) c-spine CT examinations from the American College of Radiology Dose Index Registry, July 2011 through December 2014. We used the volume CT dose index (CTDIvol) as the radiation dose estimate and used summary statistics to describe patient and hospital characteristics. Results: There were 12,218 pediatric CT c-spine examinations performed across 296 participating hospitals. Fifty-six percent were in male patients, and 79% were in children older than 10 years. Most hospitals (55%) were community hospitals without trauma designations, and the largest proportion of examinations (41%) were performed at these hospitals. The median CTDIvol was 15 mGy (interquartile range = 9 to 23 mGy) representing a more than 2.5-fold difference between the 25th and 75th percentiles. Pediatric hospitals (both trauma and nontrauma centers) delivered the lowest CTDIvol across all age groups and showed the least amount of variability in dose. Conclusions: There is significant variation in the radiation dose index for pediatric c-spine CT examinations. Pediatric hospitals practice at lower CT dose estimates than other hospitals. Individual hospitals should examine their practices in an effort to ensure standardization and optimization of CT parameters to minimize radiation exposures to pediatric patients. (C) 2015 by the Society for Academic Emergency Medicine
引用
收藏
页码:1499 / 1505
页数:7
相关论文
共 46 条
  • [1] American Academy of Pediatrics, 2015, SECT RAD WHAT EV PED
  • [2] American Association of Physicists in Medicine, 2015, MEAS REP MAN RAD DOS
  • [3] American College of Radiology, DOSE IND REG
  • [4] American College of Surgeons, 2012, ADV TRAUM LIF SUPP P
  • [5] American Trauma Society, Trauma center levels explained
  • [6] Utility of a cervical spine clearance protocol after trauma in children between 0 and 3 years of age Clinical article
    Anderson, Richard C. E.
    Kan, Peter
    Vanaman, Monique
    Rubsam, Jeanne
    Hansen, Kristine W.
    Scaife, Eric R.
    Brockmeyer, Douglas L.
    [J]. JOURNAL OF NEUROSURGERY-PEDIATRICS, 2010, 5 (03) : 292 - 296
  • [7] [Anonymous], ALL RAD PED IM
  • [8] Australian Government, AUSTR NAT PAED DIAGN
  • [9] Baert AL., 2007, RAD DOSE ADULT PEDIA
  • [10] Current concepts - Computed tomography - An increasing source of radiation exposure
    Brenner, David J.
    Hall, Eric J.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) : 2277 - 2284