Osteogenesis of 3D printed porous Ti6Al4V implants with different pore sizes

被引:255
作者
Ran, Qichun [1 ]
Yang, Weihu [1 ]
Hu, Yan [1 ]
She, Xinkun [1 ]
Yu, Yonglin [1 ]
Xiang, Yang [1 ]
Cai, Kaiyong [1 ]
机构
[1] Chongqing Univ, Coll Bioengn, Key Lab Biorheol Sci & Technol, Minist Educ, Chongqing 400044, Peoples R China
基金
中国国家自然科学基金;
关键词
3D printing; Porous Ti6Al4V scaffold; Mechanical property; Cell behavior; Osteointegration; MICRO-COMPUTED-TOMOGRAPHY; IN-VIVO; TITANIUM IMPLANTS; BONE INGROWTH; MECHANICAL-PROPERTIES; CORTICAL BONE; SCAFFOLDS; FABRICATION; POROSITY; GROWTH;
D O I
10.1016/j.jmbbm.2018.04.010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Selective laser melting (SLM) is one of the three-dimensional (3D) printing techniques that manufacturing versatile porous scaffolds with precise architectures for potential orthopedic application. To understand how the pore sizes of porous Ti6Al4V scaffolds affect their biological performances, we designed and fabricated porous Ti6Al4V implants with straightforward pore dimensions (500, 700, and 900 um) via SLM, termed as p500, p700, and p900 respectively. The morphological characteristics of Ti6Al4V scaffolds were assessed showing that the actual pore sizes of these scaffolds were 401 +/- 26 mu m, 607 +/- 24 mu m, 801 +/- 33 mu m, respectively. The mechanical properties of Ti6Al4V scaffolds were also evaluated showing that they were comparable to that of bone tissues. Meanwhile, the effect of pore size on biological responses was systematically investigated in vitro and in vivo. It was verified that 3D printing technique was able to fabricate porous Ti6Al4V implants with proper mechanical properties analogous to human bone. The in vitro results revealed that scaffolds with appropriate pore dimension were conducive to cell adhesion, proliferation and early differentiation. Furthermore, the porous Ti6Al4V scaffolds were implanted into the rabbit femur to investigate bone regeneration performance, the in vivo experiment showed the p700 sample was in favor of bone ingrowth into implant pores and bone-implant fixation stability. Taken together, the biological performance of p700 group with actual pore size of about 600 um was superior to other two groups. The obtained findings provide basis to individually design and fabricate suitable porous Ti6Al4V with specific geometries for orthopedic application.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
[31]   Pore functionally graded Ti6Al4V scaffolds for bone tissue engineering application [J].
Wang, Su ;
Liu, Linlin ;
Li, Kai ;
Zhu, Luchuang ;
Chen, Jian ;
Hao, Yongqiang .
MATERIALS & DESIGN, 2019, 168
[32]   Osseointegration of 3D porous and solid Ti-6Al-4V implants - Narrow gap push-out testing and experimental setup considerations [J].
Frosch, Stephan ;
Nuesse, Verena ;
Frosch, Karl-Heinz ;
Lehmann, Wolfgang ;
Buchhorn, Gottfried .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 115 (115)
[33]   Biotribocorrosion of 3D-printed silica-coated Ti6Al4V for load-bearing implants [J].
Afrouzian, Ali ;
Avila, Jose D. ;
Bandyopadhyay, Amit .
JOURNAL OF MATERIALS RESEARCH, 2021, 36 (19) :3974-3984
[34]   3D printed porous Ti6Al4V cage: Effects of additive angle on surface properties and biocompatibility; bone ingrowth in Beagle tibia model [J].
Chen, Cen ;
Hao, Ya ;
Bai, Xue ;
Ni, Junjie ;
Chung, Sung-Min ;
Liu, Fan ;
Lee, In-Seop .
MATERIALS & DESIGN, 2019, 175
[35]   Osteointegration of 3D-Printed Fully Porous Polyetheretherketone Scaffolds with Different Pore Sizes [J].
Feng, Xiaobo ;
Ma, Liang ;
Liang, Hang ;
Liu, Xiaoming ;
Lei, Jie ;
Li, Wenqiang ;
Wang, Kun ;
Song, Yu ;
Wang, Bingjin ;
Li, Gaocai ;
Li, Shuai ;
Yang, Cao .
ACS OMEGA, 2020, 5 (41) :26655-26666
[36]   A systematic review of preclinical in vivo testing of 3D printed porous Ti6Al4V for orthopedic applications, part I: Animal models and bone ingrowth outcome measures [J].
Spece, Hannah ;
Basgul, Cemile ;
Andrews, Caleb E. ;
MacDonald, Daniel W. ;
Taheri, Mitra L. ;
Kurtz, Steven M. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2021, 109 (10) :1436-1454
[37]   Electrochemical behaviour of Ti6Al4V porous structures fabricated by powder metallurgy route [J].
Singh, Maninder ;
Gill, Amoljit Singh ;
Deol, Parneet Kaur .
JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2024, 14 (04) :473-486
[38]   Functionalization of 3D printed Ti6Al4V high-porous spinal implant surface with use of plasma electrolytic oxidation [J].
Orlowska, Ada ;
Kajzer, Wojciech ;
Goldsztajn, Karolina ;
Gawron, Anna ;
Godzierz, Marcin ;
Nowinska, Katarzyna ;
Basiaga, Marcin ;
Simka, Wojciech ;
Szewczenko, Janusz .
APPLIED SURFACE SCIENCE, 2024, 659
[39]   Influence of porosity on mechanical properties and in vivo response of Ti6Al4V implants [J].
Bandyopadhyay, Amit ;
Espana, Felix ;
Balla, Vamsi Krishna ;
Bose, Susmita ;
Ohgami, Yusuke ;
Davies, Neal M. .
ACTA BIOMATERIALIA, 2010, 6 (04) :1640-1648
[40]   Porous Ti6Al4V scaffolds directly fabricated by 3D fibre deposition technique: Effect of nozzle diameter [J].
J. P. Li ;
J. R. de Wijn ;
C. A. van Blitterswijk ;
K. de. Groot .
Journal of Materials Science: Materials in Medicine, 2005, 16 :1159-1163