Development of a fully automated peripheral anterior chamber depth analyzer and evaluation of its accuracy

被引:11
作者
Kashiwagi, Kenji [1 ]
Shinbayashi, Etsuko [1 ]
Tsukahara, Shigeo [1 ]
机构
[1] Univ Yamanashi, Fac Med, Dept Ophthalmol, Yamanashi 4093898, Japan
关键词
peripheral anterior chamber depth; angle-closure glaucoma; biometry;
D O I
10.1097/01.ijg.0000212256.25573.44
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to improve the scanning peripheral anterior chamber depth analyzer (SPAC) for measuring anterior chamber depth (ACD), differentiating eyes with shallow anterior chamber, and automatically categorizing eyes into subgroups based on the ACD values. We also investigated its accuracy for measuring anterior ocular biometry. Materials and Methods: The improved SPAC system was equipped with an auto-focusing system for measuring ACD from the optical axis to the limbus without contacting the ocular surface, in addition to an auto-measuring system for determining central corneal thickness (CCT) and corneal radius of curvature (CRC). This system was also equipped with an auto-diagnosing program for differentiating eyes with narrow angle and an auto-classifying program for categorizing eyes into 12 subgroups according to the ACD Values. A dummy eye was used for investigating the measurement accuracy and reproducibility of CCT, CRC, and ACD. Measurement duration and clinical availability were investigated using healthy subjects and glaucoma patients. Results: The SPAC-measured CCT, CRC, and ACD values were very similar to the theoretical values obtained from the dummy eye and their coefficients of variation were less than 1%, This system completed ACD measurement in 15.6 +/- 1.0 seconds and the mean coefficient of variation of ACD was 8.8 +/- 2.3%. The improved SPAC system successfully differentiated eyes with narrow angle from those with wide open angle. Conclusions: The improved SPAC system can measure ACD easily with good accuracy and reproducibility, and is considered to be suitable for evaluating ACD in routine examinations and screening eyes with narrow angle.
引用
收藏
页码:388 / 393
页数:6
相关论文
共 12 条
[1]   Acute primary angle closure in an Asian population - Long-term outcome of the fellow eye after prophylactic laser peripheral iridotomy [J].
Ang, LPK ;
Aung, T ;
Chew, PTK .
OPHTHALMOLOGY, 2000, 107 (11) :2092-2096
[2]  
BOKER T, 1995, OPHTHALMIC RES, V27, P104
[3]   ANTERIOR-CHAMBER DEPTH MEASUREMENT USING THE SLIT-LAMP MICROSCOPE [J].
JACOBS, IH .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1979, 88 (02) :236-238
[4]   A newly developed peripheral anterior chamber depth analysis system: principle, accuracy, and reproducibility [J].
Kashiwagi, K ;
Kashiwagi, F ;
Toda, Y ;
Osada, K ;
Tsumura, T ;
Tsukahara, S .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (08) :1030-1035
[5]   Examination and treatment of patients with angle-closure glaucoma in Japan: Results of a nationwide survey [J].
Kashiwagi, K ;
Tsukahara, S .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 2004, 48 (02) :133-140
[6]  
Kashiwagi K, 2004, BR J OPHTHALMOL, V88, P1035, DOI DOI 10.1136/BJO.2003.036715
[7]  
KASHIWAGI K, 2005, EYE, V8, P8
[8]  
Osada Kosuke, 2004, Rinsho Ganka, V58, P715
[9]   ULTRASOUND BIOMICROSCOPY OF ANTERIOR SEGMENT STRUCTURES IN NORMAL AND GLAUCOMATOUS EYES [J].
PAVLIN, CJ ;
HARASIEWICZ, K ;
FOSTER, FS .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1992, 113 (04) :381-389
[10]   Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles [J].
Radhakrishnan, S ;
Goldsmith, J ;
Huang, D ;
Westphal, V ;
Dueker, DK ;
Rollins, AM ;
Izatt, JA ;
Smith, SD .
ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (08) :1053-1059