Accuracy of AFM measurements of the contour length of DNA fragments adsorbed on mica in air and in aqueous buffer

被引:52
|
作者
Sanchez-Sevilla, A [1 ]
Thimonier, J [1 ]
Marilley, M [1 ]
Rocca-Serra, J [1 ]
Barbet, J [1 ]
机构
[1] Univ Mediterranee, Fac Med, RGFCP, F-13385 Marseille 5, France
关键词
atomic force microscope (AFM); DNA contour length; image processing;
D O I
10.1016/S0304-3991(02)00128-6
中图分类号
TH742 [显微镜];
学科分类号
摘要
The measurement by atomic force microscope of the contour length of DNA fragments adsorbed on mica has been made as accurate as possible by revisiting the different steps of image acquisition and processing. In air, the DNA helical rise was estimated at 2.97 +/- 0.15 Angstrom per base pair (bp) (mean +/- standard deviation) by imaging a 648-bp DNA fragment and 2.95 +/- 0.14 Angstrom per bp for a 1115-bp fragment. This confirms earlier observations suggesting that drying DNA fragments on mica in the presence of nickel induces limited conformational changes. At this point the exact nature of these conformational changes remains unknown. Simple hypotheses are the transconformation of stretches of the DNA molecules to the A-form of the double helix or alteration of the helix structure at the points of contact between DNA and mica. By contrast, in aqueous buffer, the measured helical rise was 3.14 +/- 0.15 Angstrom per bp for the 648bp fragment and 3.17 +/- 0.13 Angstrom per bp for the 1115-bp fragment. Thus, measured helical rises do not depend on the fragment length and are significantly shorter than the 3.38 Angstrom per bp measured by crystallography, but close to the 3.18 Angstrom per bp found in NMR studies. These findings are discussed with respect to discrepancies in earlier results published in the literature. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:151 / 158
页数:8
相关论文
共 10 条
  • [1] Robust Deposition of Lambda DNA on Mica for Imaging by AFM in Air
    Gerling Cervantes, Nancy Anabel
    Gutierrez-Medina, Braulio
    SCANNING, 2014, 36 (06) : 561 - 569
  • [2] LINEAR CONTOUR LENGTH DEPENDENCE OF ELECTRICAL POLARIZABILITY OF NUCLEOSOMAL DNA FRAGMENTS - IMPLICATIONS FOR THE FLEXIBILITY OF DNA
    HACQUES, MF
    MARION, C
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1990, 166 (03) : 1140 - 1145
  • [3] Interfacial rheology of blood proteins adsorbed to the aqueous-buffer/air interface
    Ariola, FS
    Krishnan, A
    Vogler, EA
    BIOMATERIALS, 2006, 27 (18) : 3404 - 3412
  • [4] Double-strand breaks quantification by statistical length analysis of DNA fragments imaged with AFM
    Sofi, Kamila
    Ciesla, Michal
    Barbasz, Jakub
    Wilkosz, Natalia
    Lipiec, Ewelina
    Szymonski, Marek
    Bialas, Piotr
    MEASUREMENT, 2022, 198
  • [5] QUANTITATIVE-DETERMINATION OF CHANGES OF DNA CONTOUR LENGTH AND FLEXIBILITY FROM VISCOSITY MEASUREMENTS
    REINERT, KE
    JOURNAL OF MOLECULAR BIOLOGY, 1972, 72 (03) : 601 - 607
  • [6] MEASUREMENTS OF MONOVALENT AND DIVALENT COUNTERION DISTRIBUTIONS AROUND PERSISTENCE LENGTH DNA FRAGMENTS IN SOLUTION
    CHANG, SL
    CHEN, SH
    RILL, RL
    LIN, JS
    JOURNAL OF PHYSICAL CHEMISTRY, 1990, 94 (21): : 8025 - 8028
  • [7] Direct AFM force measurements between air bubbles in aqueous monodisperse sodium poly(styrene sulfonate) solutions
    Browne, Christine
    Tabor, Rico F.
    Grieser, Franz
    Dagastine, Raymond R.
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2015, 451 : 69 - 77
  • [8] DETERMINATION OF CHANGES OF DNA CONTOUR LENGTH AND FLEXIBILITY FROM VISCOSITY MEASUREMENTS - EXTENSION TO MAJOR CONFORMATIONAL-CHANGES AND IMPROVEMENT OF SECOND-ORDER APPROXIMATION
    REINERT, KE
    GELLER, K
    STUDIA BIOPHYSICA, 1974, 45 : 1 - 11
  • [9] Direct AFM force measurements between air bubbles in aqueous polydisperse sodium poly(styrene sulfonate) solutions: Effect of collision speed, polyelectrolyte concentration and molar mass
    Browne, Christine
    Tabor, Rico F.
    Grieser, Franz
    Dagastine, Raymond R.
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2015, 449 : 236 - 245
  • [10] MEASUREMENT OF DNA LENGTH BY GEL-ELECTROPHORESIS .1. IMPROVED ACCURACY OF MOBILITY MEASUREMENTS USING A DIGITAL MICRODENSITOMETER AND COMPUTER-PROCESSING
    ELDER, JK
    AMOS, A
    SOUTHERN, EM
    SHIPPEY, GA
    ANALYTICAL BIOCHEMISTRY, 1983, 128 (01) : 223 - 226