Time-resolved contrast-enhanced MR angiography of the thorax in adults with congenital heart disease

被引:18
|
作者
Mohrs, Oliver K.
Petersen, Steffen E.
Voigtlaender, Thomas
Peters, Jutta
Nowak, Bernd
Heinemann, Markus K.
Kauczor, Hans-Ulrich
机构
[1] Alice Hosp, Dept Cardiovasc Imaging, Darmstadt Radiol, D-64287 Darmstadt, Germany
[2] German Canc Res Ctr, Dept Radiol, D-6900 Heidelberg, Germany
[3] Univ Oxford, Ctr Clin MR Res, Oxford, England
[4] CCB, Dept Cardiol, Frankfurt, Germany
[5] Goethe Univ Frankfurt, Dept Radiol, D-6000 Frankfurt, Germany
[6] Johannes Gutenberg Univ Mainz, Dept Pediat Surg, D-6500 Mainz, Germany
关键词
cardiac imaging; cardiovascular imaging; congenital heart disease; conventional angiography; heart; MR angiography; thorax;
D O I
10.2214/AJR.05.0403
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The aim of this study was to evaluate the diagnostic value of time-resolved contrast-enhanced MR angiography in adults with congenital heart disease. SUBJECTS AND METHODS. Twenty patients with congenital heart disease (mean age, 38 14 years; range, 16-73 years) underwent contrast-enhanced turbo fast low-angle shot MR angiography. Thirty consecutive coronal 3D slabs with a frame rate of 1-second duration were acquired. The mask defined as the first data set was subtracted from subsequent images. Image quality was evaluated using a 5-point scale (from 1, not assessable, to 5, excellent image quality). Twelve diagnostic parameters yielded 1 point each in case of correct diagnosis (binary analysis into normal or abnormal) and were summarized into three categories: anatomy of the main thoracic vessels (maximum, 5 points), sequential cardiac anatomy (maximum, 5 points), and shunt detection (maximum, 2 points). The results were compared with a combined clinical reference comprising medical or surgical reports and other imaging studies. Diagnostic accuracies were calculated for each of the parameters as well as for the three categories. RESULTS. The mean image quality was 3.7 +/- 1.0. Using a binary approach, 220 (92%) of the 240 single diagnostic parameters could be analyzed. The percentage of maximum diagnostic points, the sensitivity, the specificity, and the positive and the negative predictive values were all 100% for the anatomy of the main thoracic vessels; 97%, 87%, 100%, 100%, and 96% for sequential cardiac anatomy; and 93%, 93%, 92%, 88%, and 96% for shunt detection. CONCLUSION. Time-resolved contrast-enhanced MR angiography provides, in one breath-hold, anatomic and qualitative functional information in adult patients with congenital heart disease. The high diagnostic accuracy allows the investigator to tailor subsequent specific MR sequences within the same session.
引用
收藏
页码:1107 / 1114
页数:8
相关论文
共 50 条
  • [21] Time-resolved contrast-enhanced pulmonary MR angiography using sensitivity encoding (SENSE)
    Ohno, Y
    Kawamitsu, H
    Higashino, T
    Takenaka, D
    Watanabe, H
    van Cauteren, M
    Fujii, M
    Hatabu, H
    Sugimura, K
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) : 330 - 336
  • [22] Time-of-Arrival Mapping at Three-dimensional Time-resolved Contrast-enhanced MR Angiography
    Riederer, Stephen J.
    Haider, Clifton R.
    Borisch, Eric A.
    RADIOLOGY, 2009, 253 (02) : 532 - 542
  • [23] Time-Resolved Contrast-Enhanced MR Angiography of the Lower Limbs: Solving the Problem of Venous Overlap
    Floery, D.
    Fellner, F. A.
    Fellner, C.
    Ginthoer, C. M.
    Uder, M.
    Pallwein-Prettner, L.
    Roeper-Kelmayr, J.
    Dirisamer, A.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (02): : 136 - 143
  • [24] Time-resolved contrast-enhanced MR angiography with single-echo Dixon fat suppression
    Stinson, Eric G.
    Trzasko, Joshua D.
    Campeau, Norbert G.
    Glockner, James F.
    Huston, John, III
    Young, Phillip M.
    Riederer, Stephen J.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (04) : 1556 - 1567
  • [25] Time-resolved, contrast-enhanced 3D MR angiography in the subclavian steal effect
    Schubert, R.
    VASA-EUROPEAN JOURNAL OF VASCULAR MEDICINE, 2010, 39 (01) : 85 - 93
  • [26] Carotid bifurcation: Evaluation of time-resolved three-dimensional contrast-enhanced MR angiography
    Carroll, TJ
    Korosec, FR
    Petermann, GM
    Grist, TM
    Turski, PA
    RADIOLOGY, 2001, 220 (02) : 525 - 532
  • [27] Contrast-Enhanced MR Angiography of Cavopulmonary Connections in Adult Patients With Congenital Heart Disease
    Wagner, Moritz
    Kim-Lien Nguyen
    Khan, Sarah
    Mirsadraee, Saeed
    Satou, Gary M.
    Aboulhosn, Jamil
    Finn, J. Paul
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : W565 - W574
  • [28] Time-resolved contrast-enhanced MR angiography: Value of hemodynamic information in the assessment of vascular diseases
    Maj, Edyta
    Cieszanowski, Andrzej
    Rowinski, Olgierd
    Wojtaszek, Mikolaj
    Szostek, Malgorzata
    Tworus, Robert
    POLISH JOURNAL OF RADIOLOGY, 2010, 75 (01) : 52 - 60
  • [29] Subtraction MR Venography Acquired from Time-Resolved Contrast-Enhanced MR Angiography: Comparison with Phase-Contrast MR Venography and Single-Phase Contrast-Enhanced MR Venography
    Jang, Jinhee
    Kim, Bum-Soo
    Sung, Jinkyeong
    Kim, Bom-Yi
    Choi, Hyun Seok
    Jung, So-Lyung
    Ahn, Kook-Jin
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (06) : 1353 - 1363
  • [30] Time-resolved contrast-enhanced magnetic resonance angiography of the lower extremity
    Krause, UJ
    Pabst, T
    Kenn, W
    Wittenberg, G
    Hahn, D
    ANGIOLOGY, 2004, 55 (02) : 119 - 125