Time-resolved contrast-enhanced MR angiography of the thorax in adults with congenital heart disease

被引:18
作者
Mohrs, Oliver K.
Petersen, Steffen E.
Voigtlaender, Thomas
Peters, Jutta
Nowak, Bernd
Heinemann, Markus K.
Kauczor, Hans-Ulrich
机构
[1] Alice Hosp, Dept Cardiovasc Imaging, Darmstadt Radiol, D-64287 Darmstadt, Germany
[2] German Canc Res Ctr, Dept Radiol, D-6900 Heidelberg, Germany
[3] Univ Oxford, Ctr Clin MR Res, Oxford, England
[4] CCB, Dept Cardiol, Frankfurt, Germany
[5] Goethe Univ Frankfurt, Dept Radiol, D-6000 Frankfurt, Germany
[6] Johannes Gutenberg Univ Mainz, Dept Pediat Surg, D-6500 Mainz, Germany
关键词
cardiac imaging; cardiovascular imaging; congenital heart disease; conventional angiography; heart; MR angiography; thorax;
D O I
10.2214/AJR.05.0403
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The aim of this study was to evaluate the diagnostic value of time-resolved contrast-enhanced MR angiography in adults with congenital heart disease. SUBJECTS AND METHODS. Twenty patients with congenital heart disease (mean age, 38 14 years; range, 16-73 years) underwent contrast-enhanced turbo fast low-angle shot MR angiography. Thirty consecutive coronal 3D slabs with a frame rate of 1-second duration were acquired. The mask defined as the first data set was subtracted from subsequent images. Image quality was evaluated using a 5-point scale (from 1, not assessable, to 5, excellent image quality). Twelve diagnostic parameters yielded 1 point each in case of correct diagnosis (binary analysis into normal or abnormal) and were summarized into three categories: anatomy of the main thoracic vessels (maximum, 5 points), sequential cardiac anatomy (maximum, 5 points), and shunt detection (maximum, 2 points). The results were compared with a combined clinical reference comprising medical or surgical reports and other imaging studies. Diagnostic accuracies were calculated for each of the parameters as well as for the three categories. RESULTS. The mean image quality was 3.7 +/- 1.0. Using a binary approach, 220 (92%) of the 240 single diagnostic parameters could be analyzed. The percentage of maximum diagnostic points, the sensitivity, the specificity, and the positive and the negative predictive values were all 100% for the anatomy of the main thoracic vessels; 97%, 87%, 100%, 100%, and 96% for sequential cardiac anatomy; and 93%, 93%, 92%, 88%, and 96% for shunt detection. CONCLUSION. Time-resolved contrast-enhanced MR angiography provides, in one breath-hold, anatomic and qualitative functional information in adult patients with congenital heart disease. The high diagnostic accuracy allows the investigator to tailor subsequent specific MR sequences within the same session.
引用
收藏
页码:1107 / 1114
页数:8
相关论文
共 15 条
  • [1] Magnetic resonance angiography of criss-cross heart
    Araoz, PA
    Reddy, GP
    Thomson, PD
    Higgins, CB
    [J]. CIRCULATION, 2002, 105 (04) : 537 - 538
  • [2] Time-resolved three-dimensional magnetic resonance angiography for assessing a pulmonary artery sling in a pediatric patient
    Eichhorn, J
    Fink, C
    Bock, M
    Delorme, S
    Brockmeier, K
    Ulmer, HE
    [J]. CIRCULATION, 2002, 106 (14) : E61 - E62
  • [3] Pulmonary arteriovenous malformation:: Characterization with time-resolved ultrafast 3D MR angiography
    Goyen, M
    Ruehm, SG
    Jagenburg, A
    Barkhausen, J
    Kröger, K
    Debatin, JF
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (03) : 458 - 460
  • [4] Time-resolved projection angiography after bolus injection of contrast agent
    Hennig, J
    Scheffler, K
    Laubenberger, J
    Strecker, R
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (03) : 341 - 345
  • [5] DIAGNOSIS IN ADOLESCENTS AND ADULTS WITH CONGENITAL HEART-DISEASE - PROSPECTIVE ASSESSMENT OF INDIVIDUAL AND COMBINED ROLES OF MAGNETIC-RESONANCE-IMAGING AND TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    HIRSCH, R
    KILNER, PJ
    CONNELLY, MS
    REDINGTON, AN
    SUTTON, MGS
    SOMERVILLE, J
    [J]. CIRCULATION, 1994, 90 (06) : 2937 - 2951
  • [6] Diagnosis of patent foramen ovale using contrast-enhanced dynamic MRI:: A pilot study
    Mohrs, OK
    Petersen, SE
    Erkapic, D
    Rubel, C
    Schräder, R
    Nowak, B
    Fach, WA
    Kauczor, HU
    Voigtlaender, T
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (01) : 234 - 240
  • [7] Morphologic and functional assessment of vascular abnormalities of the pulmonary vasculature by breath-hold MR techniques
    Mohrs, OK
    Voigtländer, T
    Heussel, CP
    Von Bardeleben, S
    Düber, C
    Kreitner, KF
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (04): : 467 - 473
  • [8] Usefulness of segmented TrueFISP cardiac pulse sequence in evaluation of congenital and acquired adult cardiac abnormalities
    Pereles, FS
    Kapoor, V
    Carr, JC
    Simonetti, OP
    Krupinski, EA
    Baskaran, V
    Finn, JP
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (05) : 1155 - 1160
  • [9] Quantification of shunt volumes in congenital heart diseases using a breath-hold MR phase contrast technique -: comparison with oximetry
    Petersen, SE
    Voigtländer, T
    Kreitner, KF
    Kalden, P
    Wittlinger, T
    Scharhag, J
    Horstick, G
    Becker, D
    Hommel, G
    Thelen, M
    Meyer, J
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2002, 18 (01): : 53 - 60
  • [10] VENOATRIAL PATHWAYS AFTER THE MUSTARD OPERATION FOR TRANSPOSITION OF THE GREAT-ARTERIES - ANATOMIC AND FUNCTIONAL MR-IMAGING
    SAMPSON, C
    KILNER, PJ
    HIRSCH, R
    REES, RSO
    SOMERVILLE, J
    UNDERWOOD, SR
    [J]. RADIOLOGY, 1994, 193 (01) : 211 - 217