Relative strength of thoracic vertebrae in axial compression versus flexion

被引:33
作者
Buckley, Jenni M. [1 ]
Kuo, Calvin C.
Cheng, Liu C.
Loo, Kenneth
Motherway, Julie
Slyfield, Craig
Deviren, Vedat
Ames, Christopher [2 ]
机构
[1] Univ Calif San Francisco, San Francisco Gen Hosp, Dept Orthopaed Surg, Orthopaed Tramna Inst,Biomech Testing Facil, San Francisco, CA 94110 USA
[2] Univ Calif San Francisco, Dept Neurosurg, San Francisco, CA 94110 USA
关键词
Osteoporosis; Fracture; Vertebra; Flexion; Quantitative computed tomography; QUANTITATIVE COMPUTED-TOMOGRAPHY; X-RAY ABSORPTIOMETRY; BONE-MINERAL DENSITY; LUMBAR VERTEBRAE; TRABECULAR BONE; IN-VITRO; BIOMECHANICAL CONSEQUENCES; OSTEOPOROTIC FRACTURES; THORACOLUMBAR SPINE; REGIONAL-VARIATIONS;
D O I
10.1016/j.spinee.2009.02.010
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Noninvasive strength assessment techniques are the clinical standard in the diagnosis and treatment of osteoporotic vertebral fractures, and the efficacy of these protocols depends on their ability to predict vertebral strength at all at-risk spinal levels under multiple physiological loading conditions. PURPOSE: To assess differences in vertebral strength between loading modes and across spinal levels. STUDY DESIGN/SETTING: This study examined the relative strength of isolated vertebral bodies in compression versus flexion. METHODS: Destructive biomechanical tests were conducted on 30 pairs of donor-matched, isolated thoracic vertebral bodies (T9 and TIO; F = 19, M = 11; 87+5 years old, max=97 years old, min=80 years old) in both uniform axial compression and flexion using previously described protocols. Quantitative computed tomography (QCT) scans were taken before mechanical testing and used to obtain bone mineral density (BMD) and "mechanics of solids" (MOS) measures, such as axial and bending rigidities. RESULTS: Compressive strength was higher than flexion strength for each donor by 940+152 N (p<.001, paired t test), and vertebral strengths in the two loading modes were moderately correlated (adjusted R(2)=0.50, p<.001). For both compression and flexion loading modes, adjacent-level BMD and MOS metrics had approximately half the predictive capacity as same-level measurements, and BMD and MOS values were only moderately correlated across spinal levels. CONCLUSIONS: The results of this study are important in designing clinical test protocols for assessing vertebral fracture risk. Because vertebral body flexion and compressive strength are not strongly correlated and flexion strength is significantly less than compressive strength, it is imperative to investigate a patient's spinal structural capacity under bending loading conditions. Furthermore, our work suggests that clinicians using QCT-based measures should perform site-specific strength assessments on each at-risk spinal level. Future work should focus on improving the accuracy of densitometric measures in predicting vertebral strength in flexion and also on examining same- versus adjacent-level strength assessment for radiographic techniques with lower X-ray dosage, such as dual-energy X-ray absorptiometry. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:478 / 485
页数:8
相关论文
共 45 条
  • [1] A TECHNIQUE FOR QUANTIFYING THE BENDING MOMENT ACTING ON THE LUMBAR SPINE INVIVO
    ADAMS, MA
    DOLAN, P
    [J]. JOURNAL OF BIOMECHANICS, 1991, 24 (02) : 117 - 126
  • [2] Clinical use of bone densitometry - Clinical applications
    Bates, DW
    Black, DM
    Cummings, SR
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2002, 288 (15): : 1898 - 1900
  • [3] PREDICTION OF THE COMPRESSIVE STRENGTH OF HUMAN LUMBAR VERTEBRAE
    BRINCKMANN, P
    BIGGEMANN, M
    HILWEG, D
    [J]. SPINE, 1989, 14 (06) : 606 - 610
  • [4] Quantitative computed tomography-based predictions of vertebral strength in anterior bending
    Buckley, Jenni M.
    Cheng, Liu
    Loo, Kenneth
    Slyfield, Craig
    Xu, Zheng
    [J]. SPINE, 2007, 32 (09) : 1019 - 1027
  • [5] Comparison of quantitative computed tomography-based measures in predicting vertebral compressive strength
    Buckley, Jenni M.
    Loo, Kenneth
    Motherway, Julie
    [J]. BONE, 2007, 40 (03) : 767 - 774
  • [6] BUCKLEY JM, 2007, T ORTHOP RES SOC
  • [7] QUANTITATIVE COMPUTED-TOMOGRAPHY FOR PREDICTION OF VERTEBRAL FRACTURE RISK
    CANN, CE
    GENANT, HK
    KOLB, FO
    ETTINGER, B
    [J]. BONE, 1985, 6 (01) : 1 - 7
  • [8] Cross-calibration, precision and patient dose measurements in preparation for clinical trials using dual energy X-ray absorptiometry of the lumbar spine
    Cawte, SA
    Pearson, D
    Green, DJ
    Maslanka, WB
    Miller, CG
    Rogers, AT
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (856) : 354 - 362
  • [9] Prediction of vertebral strength in vitro by spinal bone densitometry and calcaneal ultrasound
    Cheng, XG
    Nicholson, PHF
    Boonen, S
    Lowet, G
    Brys, P
    Aerssens, J
    VanderPerre, G
    Dequeker, J
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 (10) : 1721 - 1728
  • [10] COOPER C, 1993, BONE, V14, pS89