Aging of imaging properties of a CMOS flat-panel detector for dental cone-beam computed tomography

被引:4
|
作者
Kim, D. W. [1 ]
Han, J. C. [1 ,3 ]
Yun, S. [1 ,3 ]
Kim, H. K. [1 ,2 ]
机构
[1] Pusan Natl Univ, Sch Mech Engn, Busan 46241, South Korea
[2] Pusan Natl Univ, Ctr Adv Med Engn Res, Busan 46241, South Korea
[3] Samsung Elect Co, Suwon 16677, Gyeonggi Do, South Korea
来源
关键词
Computerized Tomography (CT) and Computed Radiography (CR); X-ray radiography and digital radiography (DR); X-RAY-DETECTOR; PHOTODIODE-ARRAY DETECTORS; ACTIVE PIXEL SENSORS; SCINTILLATING CRYSTALS; RADIATION-DAMAGE; GAIN; CT; TECHNOLOGIES; MAMMOGRAPHY; PERFORMANCE;
D O I
10.1088/1748-0221/12/01/P01005
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have experimentally investigated the long-term stability of imaging properties of a flat-panel detector in conditions used for dental x-ray imaging. The detector consists of a CsI: Tl layer and CMOS photodiode pixel arrays. Aging simulations were carried out using an 80-kVp x-ray beam at an air-kerma rate of approximately 5 mGy s(-1) at the entrance surface of the detector with a total air kerma of up to 0.6 kGy. Dark and flood-field images were periodically obtained during irradiation, and the mean signal and noise levels were evaluated for each image. We also evaluated the modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). The aging simulation showed a decrease in both the signal and noise of the gain-offset-corrected images, but there was negligible change in the signal-to-noise performance as a function of the accumulated dose. The gain-offset correction for analyzing images resulted in negligible changes in MTF, NPS, and DQE results over the total dose. Continuous x-ray exposure to a detector can cause degradation in the physical performance factors such the detector sensitivity, but linear analysis of the gain-offset-corrected images can assure integrity of the imaging properties of a detector during its lifetime.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Image noise due to quantum fluctuations in flat-panel detector based cone-beam CT imaging
    Zhang, Y
    Ning, R
    Conover, D
    Yu, Y
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 656 - 663
  • [22] C-arm-based flat-panel detector cone-beam computed tomography venography in the diagnosis of iliac vein compression syndrome
    Wang Chang-Ming
    Zhang Wei-Liang
    Li Xuan
    中华医学杂志英文版, 2021, 134 (04) : 431 - 438
  • [23] C-arm-based flat-panel detector cone-beam computed tomography venography in the diagnosis of iliac vein compression syndrome
    Wang, Chang-Ming
    Zhang, Wei-Liang
    Li, Xuan
    CHINESE MEDICAL JOURNAL, 2021, 134 (04) : 431 - 438
  • [24] Cone-beam CT with a flat-panel imager: Noise considerations for fully 3-D computed tomography
    Siewerdsen, JH
    Jaffray, DA
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 408 - 416
  • [25] Low-dose 2.5 MV cone-beam computed tomography with thick CsI flat-panel imager
    Tang, Grace
    Moussot, Christopher
    Morf, Daniel
    Seppi, Edward
    Amols, Howard
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 235 - 245
  • [26] The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors
    Siewerdsen, JH
    Moseley, DJ
    Bakhtiar, B
    Richard, S
    Jaffray, DA
    MEDICAL PHYSICS, 2004, 31 (12) : 3506 - 3520
  • [27] C-Arm Cone-Beam Computed Tomography with a flat panel detector for intraoperative renal imaging assessment of image quality
    Burks, Frank N.
    Sebastion, Evelyn L.
    Kim, Leonard H.
    Gonzalez, Jose A.
    Martinez, Alvaro A.
    Kernen, Kenneth M.
    Hafron, Jason M.
    JOURNAL OF UROLOGY, 2008, 179 (04): : 679 - 680
  • [28] Patient-specific scatter correction for flat-panel detector-based cone-beam CT imaging
    Zhao, Wei
    Brunner, Stephen
    Niu, Kai
    Schafer, Sebastian
    Royalty, Kevin
    Chen, Guang-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (03): : 1339 - 1365
  • [29] Cone-beam CT breast imaging with a flat panel detector - a simulation study
    Chen, LY
    Shaw, CC
    Tu, SJ
    Altunbas, M
    Wang, T
    Lai, CJ
    Liu, XM
    Kappadath, SC
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 943 - 951
  • [30] Examination of the dental cone-beam CT equipped with flat-panel-detector (FPD)
    Ito, Rieko
    Fujita, Naotoshi
    Kodera, Yoshie
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961