Photoacoustic Spectroscopy for the Quantification of N2O in the Off Gas of Wastewater Treatment Plants

被引:18
作者
Thaler, Klemens M. [1 ]
Berger, Christoph [1 ]
Leix, Carmen [2 ]
Drewes, Joerg [2 ]
Niessner, Reinhard [1 ]
Haisch, Christoph [1 ]
机构
[1] Tech Univ Munich, Inst Hydrochemistry, Chair Analyt Chem, Marchioninistrasse 17, D-81377 Munich, Germany
[2] Tech Univ Munich, Chair Urban Water Syst Engn, AM Coulombwall 3, D-85748 Garching, Germany
关键词
CASCADE LASER SPECTROMETER; TRACE GAS; SENSOR; METHANE; CARBON; CH4; CO2;
D O I
10.1021/acs.analchem.7b00491
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Different configurations of photoacoustic (PA) setups for the online-measurement of gaseous N2O, employing semiconductor lasers at 2.9 and 4.5 mu m, were developed and tested. Their performance was assessed with respect to the analysis of N2O emissions from wastewater treatment plants. For this purpose, the local N2O emissions of a wastewater treatment bioreactor was sampled by a dedicated mobile sampling device, and the total N2O emissions were analyzed in the gastight headspace of the bioreactor. We found that the use of a quantum-cascade laser emitting at about 4.53 mu m, operated in a wavelength modulation mode, in combination with a conventional longitudinal PA cell yielded the highest sensitivity (<100 ppbv). However, we also observed a strong cross-sensitivity to humidity, which can be explained by increased V-T relaxation. This observation in combination with the limited dynamic range (max cone. similar to 3000 ppmv) led us to the use of the less-sensitive but spectroscopically more robust 2.9 mu m laser. A detection limit below 1 ppmv, a dynamic range of more than 4 orders of magnitude, no influence of humidity or any other substance relevant to the off-gas analysis, as well as a comparable low price of the laser source made it the ideal tool for N2O analyses of the off-gas of a wastewater treatment plant. Such a system was implemented successfully in a full-scale wastewater treatment plant. The results regarding the comparison of different PA setups can be transferred to other systems, and the optimum performance can be selected according, to the specific demands.
引用
收藏
页码:3795 / 3801
页数:7
相关论文
共 31 条
  • [1] ANALYSIS OF ENERGY-TRANSFER FOR THERMALLY AVAILABLE VIBRATIONAL ENERGY-LEVELS AS MEASURED BY PHOTOACOUSTIC AND INFRARED-EMISSION TECHNIQUES
    AVRAMIDES, E
    HUNTER, TF
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS II, 1979, 75 : 515 - 527
  • [2] VIBRATIONAL-TRANSLATIONAL/ROTATIONAL AND VIBRATIONAL-VIBRATIONAL PROCESSES IN METHANE - OPTOACOUSTIC MEASUREMENTS
    AVRAMIDES, E
    HUNTER, TF
    [J]. CHEMICAL PHYSICS, 1981, 57 (03) : 441 - 451
  • [3] Development and characterization of a mobile photoacoustic sensor for on-line soot emission monitoring in diesel exhaust gas
    Beck, HA
    Niessner, R
    Haisch, C
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (08) : 1136 - 1143
  • [4] WAVELENGTH MODULATION IN PHOTO-ACOUSTIC SPECTROSCOPY
    CASTLEDEN, SL
    KIRKBRIGHT, GF
    SPILLANE, DEM
    [J]. ANALYTICAL CHEMISTRY, 1981, 53 (14) : 2228 - 2231
  • [5] Quantum cascade laser photoacoustic detection of nitrous oxide released from soils for biofuel production
    Couto, F. M.
    Sthel, M. S.
    Castro, M. P. P.
    da Silva, M. G.
    Rocha, M. V.
    Tavares, J. R.
    Veiga, C. F. M.
    Vargas, H.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2014, 117 (03): : 897 - 903
  • [6] Compact TDLAS based sensor design using interband cascade lasers for mid-IR trace gas sensing
    Dong, Lei
    Tittel, Frank K.
    Li, Chunguang
    Sanchez, Nancy P.
    Wu, Hongpeng
    Zheng, Chuantao
    Yu, Yajun
    Sampaolo, Angelo
    Griffin, Robert J.
    [J]. OPTICS EXPRESS, 2016, 24 (06): : A528 - A535
  • [7] Detection of methyl mercaptan with a 3393-nm distributed feedback interband cascade laser
    Du, Zhenhui
    Zhen, Weimeng
    Zhang, Zheyuan
    Li, Jinyi
    Gao, Nan
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2016, 122 (04):
  • [8] Mitigating off-gas emissions in the biological nitrogen removal via nitrite process treating anaerobic effluents
    Frison, Nicola
    Chiumenti, Alessandro
    Katsou, Evina
    Malamis, Simos
    Bolzonella, David
    Fatone, Francesco
    [J]. JOURNAL OF CLEANER PRODUCTION, 2015, 93 : 126 - 133
  • [9] A Fourier transform infrared trace gas and isotope analyser for atmospheric applications
    Griffith, D. W. T.
    Deutscher, N. M.
    Caldow, C.
    Kettlewell, G.
    Riggenbach, M.
    Hammer, S.
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2012, 5 (10) : 2481 - 2498
  • [10] Optimization of a compact photoacoustic quantum cascade laser spectrometer for atmospheric flux measurements:: application to the detection of methane and nitrous oxide
    Grossel, A.
    Zeninari, V.
    Parvitte, B.
    Joly, L.
    Courtois, D.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2007, 88 (03): : 483 - 492