BRACHYTHERAPY DOSIMETRY SPECIAL FEATURE: REVIEW ARTICLE In vivo dosimetry: trends and prospects for brachytherapy

被引:59
作者
Kertzscher, G. [1 ]
Rosenfeld, A. [2 ]
Beddar, S. [3 ]
Tanderup, K. [4 ]
Cygler, J. E. [5 ]
机构
[1] Tech Univ Denmark, Ctr Nucl Technol, Roskilde, Denmark
[2] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[4] Aarhus Univ Hosp, Dept Oncol, DK-8000 Aarhus, Denmark
[5] Ottawa Hosp, Ctr Canc, Dept Med Phys, Ottawa, ON, Canada
关键词
HIGH-DOSE-RATE; CERVIX CANCER BRACHYTHERAPY; PLASTIC SCINTILLATION DETECTORS; RATE INTRACAVITARY BRACHYTHERAPY; REAL-TIME VERIFICATION; RECTAL WALL DOSIMETRY; HDR BRACHYTHERAPY; GEC-ESTRO; APPLICATOR RECONSTRUCTION; TEMPERATURE-DEPENDENCE;
D O I
10.1259/bjr.20140206
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The error types during brachytherapy (BT) treatments and their occurrence rates are not well known. The limited knowledge is partly attributed to the lack of independent verification systems of the treatment progression in the clinical workflow routine. Within the field of in vivo dosimetry (IVD), it is established that real-time IVD can provide efficient error detection and treatment verification. However, it is also recognized that widespread implementations are hampered by the lack of available high-accuracy IVD systems that are straightforward for the clinical staff to use. This article highlights the capabilities of the state-of-the-art IVD technology in the context of error detection and quality assurance (QA) and discusses related prospects of the latest developments within the field. The article emphasizes the main challenges responsible for the limited practice of IVD and provides descriptions on how they can be overcome. Finally, the article suggests a framework for collaborations between BT clinics that implemented IVD on a routine basis and postulates that such collaborations could improve BT QA measures and the knowledge about BT error types and their occurrence rates.
引用
收藏
页数:16
相关论文
共 119 条
[1]   Quality Control of High-Dose-Rate Brachytherapy: Treatment Delivery Analysis Using Statistical Process Control [J].
Able, Charles M. ;
Bright, Megan ;
Frizzell, Bart .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (03) :828-833
[2]   In-vivo rectal dose measurements with diodes to avoid misadministrations during intracavitary high dose rate brachytherapy for carcinoma of the cervix [J].
Alecu, R ;
Alecu, M .
MEDICAL PHYSICS, 1999, 26 (05) :768-770
[3]   Evaluation of treatment planning system of brachytherapy according to dose to the rectum delivered [J].
Allahverdi, Mahmoud ;
Sarkhosh, Mina ;
Aghili, Mahdi ;
Jaberi, Ramin ;
Adelnia, Akbar ;
Geraily, Ghazale .
RADIATION PROTECTION DOSIMETRY, 2012, 150 (03) :312-315
[4]   Time-resolved in vivo luminescence dosimetry for online error detection in pulsed dose-rate brachytherapy [J].
Andersen, Claus E. ;
Nielsen, Soren Kynde ;
Lindegaard, Jacob Christian ;
Tanderup, Kari .
MEDICAL PHYSICS, 2009, 36 (11) :5033-5043
[5]   Characterization of a fiber-coupled Al2O3:C luminescence dosimetry system for online in vivo dose verification during 192Ir brachytherapy [J].
Andersen, Claus E. ;
Nielsen, Soren Kynde ;
Greilich, Steffen ;
Helt-Hansen, Jakob ;
Lindegaard, Jacob Christian ;
Tanderup, Kari .
MEDICAL PHYSICS, 2009, 36 (03) :708-718
[6]   Critical structure movement in cervix brachytherapy [J].
Anderson, Clare ;
Lowe, Gerry ;
Wills, Rachel ;
Inchley, David ;
Beenstock, Victoria ;
Bryant, Linda ;
Chapman, Caroline ;
Hoskin, Peter J. .
RADIOTHERAPY AND ONCOLOGY, 2013, 107 (01) :39-45
[7]  
[Anonymous], 2013, SCI WORLD J, DOI DOI 10.1117/1.JB0.18.11.110504
[8]   A mathematical formalism for hyperspectral, multipoint plastic scintillation detectors [J].
Archambault, Louis ;
Therriault-Proulx, Francois ;
Beddar, Sam ;
Beaulieu, Luc .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (21) :7133-7145
[9]  
ASHTON LP, 2004, ANN ICRP, V97
[10]  
Bahena JH, 1998, INT J RADIAT ONCOL, V41, P13