Heat transfer to the ceiling of the riser of a circulating fluidized bed

被引:2
作者
Zhang, Rui
Dutta, Animesh [1 ]
Basu, Prabir
机构
[1] Asian Inst Technol, Energy Field Study, Klongluang 12120, Pathumthani, Thailand
[2] Greenfield Res Inc, Halifax, NS B3M 1N8, Canada
[3] Dalhousie Univ, Dept Engn Mech, Halifax, NS B3J 2X4, Canada
关键词
circulating fluidized bed boiler; ceiling; heat transfer; circulation rates;
D O I
10.1016/j.ces.2006.04.022
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Very little information on the heat transfer to the ceiling of a circulating fluidized bed (CFB) boiler is available in the published literature though it constitutes a significant part of the furnace heat absorption. So, to explore this less-known heat transfer process a series of experiments were conducted at four different superficial gas velocities and three external solids circulation rates in a CFB pilot plant with a riser having a height of 5 m and a cross section of 1.0 m x 0.5 m. The experimental results suggest that both solids circulation rates and superficial gas velocities had a significant influence on the local heat transfer to the ceiling close to the riser exit to the gas solids separator. However, on the ceiling, opposite of the exit, solids circulation rates and superficial gas velocities had only a minor influence on the local heat transfer coefficients. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5907 / 5911
页数:5
相关论文
共 16 条
[1]   Heat transfer to walls of a circulating fluidized-bed furnace [J].
Basu, P ;
Nag, PK .
CHEMICAL ENGINEERING SCIENCE, 1996, 51 (01) :1-26
[2]  
BOTSIO E, 2004, THESIS DALHOUISE U
[3]  
BREITHOLTZ C, 2000, THESIS U TECHNOLOGY
[4]   Inlet and outlet effects on flow patterns in gas-solid risers [J].
Cheng, Y ;
Wei, F ;
Yang, GQ ;
Jin, Y .
POWDER TECHNOLOGY, 1998, 98 (02) :151-156
[5]   An investigation on heat transfer to the standpipe of a circulating fluidized bed boiler [J].
Dutta, A ;
Basu, P .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2003, 81 (A8) :1003-1014
[6]   An experimental investigation into the heat transfer on wing walls in a circulating fluidized bed boiler [J].
Dutta, A ;
Basu, P .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (22) :4479-4491
[7]  
Dutta A, 2002, J I ENERGY, V75, P85
[8]  
DUTTA A, 2002, THESIS DALHOUISE U H
[9]  
Dutta R, 2005, INT ENERGY J, V6
[10]  
GLICKSMAN LR, 1997, CIRCULATING FLUIDIZE, P261