Ultra fast electromagnetic field computations for RF multi-transmit techniques in high field MRI

被引:30
作者
van den Bergen, Bob [1 ]
Stolk, Christiaan C. [2 ]
van den Berg, Jan Bouwe [3 ]
Lagendijk, Jan J. W. [1 ]
Van den Berg, Cornelis A. T. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiotherapy, NL-3508 GA Utrecht, Netherlands
[2] Univ Twente, Dept Appl Math, NL-7500 AE Enschede, Netherlands
[3] Vrije Univ Amsterdam, Dept Math, NL-1081 HV Amsterdam, Netherlands
关键词
POWER DEPOSITION; B-1; DISTRIBUTION; ABSORPTION RATE; RESONANCE; HOMOGENEITY; DESIGN; ARRAY; COIL; PENETRATION; EXCITATIONS;
D O I
10.1088/0031-9155/54/5/010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new, very fast, approach for calculations of the electromagnetic excitation field for MRI is presented. The calculation domain is divided in different homogeneous regions, where for each region a general solution is obtained by a summation of suitable basis functions. A unique solution for the electromagnetic field is found by enforcing the appropriate boundary conditions between the different regions. The method combines the speed of an analytical method with the versatility of full wave simulation methods and is validated in the pelvic region against FDTD simulations at 3 and 7 T and measurements at 3 T. The high speed and accurate reproduction of measurements and FDTD calculations are believed to offer large possibilities for multi-transmit applications, where it can be used for on-line control of the global and local electric field and specific absorption rate (SAR) in the patient. As an example the method was evaluated for RF shimming with the use of 7 T simulation results, where it was demonstrated that the magnetic excitation field could be homogenized, while both the local and average SAR were reduced by 38% or more.
引用
收藏
页码:1253 / 1264
页数:12
相关论文
共 26 条
[1]   RF MAGNETIC-FIELD PENETRATION, PHASE-SHIFT AND POWER DISSIPATION IN BIOLOGICAL TISSUE - IMPLICATIONS FOR NMR IMAGING [J].
BOTTOMLEY, PA ;
ANDREW, ER .
PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (04) :630-643
[2]   ESTIMATING RADIOFREQUENCY POWER DEPOSITION IN BODY NMR IMAGING [J].
BOTTOMLEY, PA ;
REDINGTON, RW ;
EDELSTEIN, WA ;
SCHENCK, JF .
MAGNETIC RESONANCE IN MEDICINE, 1985, 2 (04) :336-349
[3]   Array-optimized composite pulse for excellent whole-brain homogeneity in high-field MRI [J].
Collins, Christopher M. ;
Wang, Zhangwei ;
Mao, Weihua ;
Fang, Jieming ;
Liu, Wanzhan ;
Smith, Michael B. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (03) :470-474
[4]   Central brightening due to constructive interference with, without, and despite dielectric resonance [J].
Collins, CM ;
Liu, WZ ;
Schreiber, W ;
Yang, QX ;
Smith, MB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (02) :192-196
[5]   Calculations of B1 distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model [J].
Collins, CM ;
Smith, MB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :692-699
[6]   AN ANALYTICAL MODEL FOR THE DESIGN OF RF RESONATORS FOR MR BODY IMAGING [J].
FOO, TKF ;
HAYES, CE ;
KANG, YW .
MAGNETIC RESONANCE IN MEDICINE, 1991, 21 (02) :165-177
[7]   COMPARISON OF LINEAR AND CIRCULAR-POLARIZATION FOR MAGNETIC-RESONANCE IMAGING [J].
GLOVER, GH ;
HAYES, CE ;
PELC, NJ ;
EDELSTEIN, WA ;
MUELLER, OM ;
HART, HR ;
HARDY, CJ ;
ODONNELL, M ;
BARBER, WD .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (02) :255-270
[8]  
Griffiths D.J., 1999, INTRO ELECTRODYNAMIC, V3rd, P11
[9]  
Hoult DI, 2000, J MAGN RESON IMAGING, V12, P46, DOI 10.1002/1522-2586(200007)12:1<46::AID-JMRI6>3.0.CO
[10]  
2-D