A noncontact resonance frequency detection technique for the assessment of the interfacial bone defect around a dental implant

被引:10
作者
Pan, Min-Chun [1 ,2 ]
Zhuang, Han-Bo [2 ]
Chen, Chin-Sung [3 ]
Wu, Jer-Whey [4 ]
Lee, Shyh-Yuan [5 ]
机构
[1] Natl Cent Univ, Grad Inst Biomed Engn, Jhongli, Taiwan
[2] Natl Cent Univ, Dept Mech Engn, Jhongli, Taiwan
[3] Cathay Gen Hosp, Dept Dent, Sijhih, Taiwan
[4] Cathay Gen Hosp, Dept Dent, Taipei, Taiwan
[5] Yang Ming Univ, Fac Dent, Sch Dent, Taipei, Taiwan
关键词
Dental implant; Interfacial bone defect; Noncontact detection; Resonance frequency analysis; ORAL IMPLANTS; STABILITY; OSSEOINTEGRATION; DEVICE;
D O I
10.1016/j.medengphy.2013.05.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study employed a noncontact resonance frequency (RF) detection technique that was developed by our group to evaluate the interfacial bone in in vitro implant-bone models. Based on our method, the implant-bone structure was excited by the acoustic energy of a loudspeaker, and its vibration response was acquired with a capacitance sensor. The spectral analysis was used to characterize the first RF value. Two types of in vitro defect models, Buccal-Lingual (BL) and Mesial-Distal (MD), were constructed for the verification. The measurements of the RF for a defect model clamped at four different heights (9, 10, 11, and 12 mm) were performed in two sensing directions (BL and MD). Moreover, each model was also analyzed using an Osstell Mentor. The obtained two parameters, RF and ISQ (Implant Stability Quotient), were statistically analyzed through one-way analysis of variance (ANOVA) and linear regression analysis for comparisons. The RF and the ISQ values obtained for all of the defect models at the four clamp heights decreased significantly (p < 0.05) with an increase in the severity of the defect. The two parameters for each imperfection increase significantly (p < 0.05) with an increase in the clamp height. Additionally, the RFs of all of the defect models are linearly correlated with their corresponding ISQs for the four clamp heights and the two measuring orientations. Therefore, our developed technique is feasible for the assessment of the postoperative healing around a dental implant. (C) 2013 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1825 / 1830
页数:6
相关论文
共 21 条
[1]   Assessment of Osstell (TM) and Periotest((R)) systems in measuring dental implant stability (in vitro study) [J].
Al-Jetaily, Samer ;
Al-Dosari, Abdullah AlFarraj .
SAUDI DENTAL JOURNAL, 2011, 23 (01) :17-21
[2]   OSSEOINTEGRATED ORAL IMPLANTS - A SWEDISH MULTICENTER STUDY OF 8139 CONSECUTIVELY INSERTED NOBELPHARMA IMPLANTS [J].
ALBREKTSSON, T ;
DAHL, E ;
ENBOM, L ;
ENGEVALL, S ;
ENGQUIST, B ;
ERIKSSON, AR ;
FELDMANN, G ;
FREIBERG, N ;
GLANTZ, PO ;
KJELLMAN, O ;
KRISTERSSON, L ;
KVINT, S ;
KONDELL, PA ;
PALMQUIST, J ;
WERNDAHL, L ;
ASTRAND, P .
JOURNAL OF PERIODONTOLOGY, 1988, 59 (05) :287-296
[3]  
[Anonymous], 1985, TISS INT DENT OSS CL
[4]  
Atsumi M, 2007, INT J ORAL MAX IMPL, V22, P743
[5]  
Behat O, 2000, INT J ORAL MAX IMPL, V15, P646
[6]  
Caulier H, 1997, INT J ORAL MAX IMPL, V12, P380
[7]   A newly designed resonance frequency analysis device for dental implant stability detection [J].
Chang, Wei-Jen ;
Lee, Sheng-Yang ;
Wu, Chen-Che ;
Lin, Che-Tong ;
Abiko, Yoshimitsu ;
Yamamichi, Nobuyuki ;
Huang, Haw-Ming .
DENTAL MATERIALS JOURNAL, 2007, 26 (05) :665-671
[8]  
DHOEDT B, 1985, DEUT ZAHNAERZTL Z, V40, P113
[9]   A no-contact vibration device for measuring implant stability [J].
Hayashi, Makoto ;
Kobayashi, Chiaki ;
Ogata, Hidehiro ;
Yamaoka, Masaru ;
Ogiso, Bunnai .
CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (09) :931-936
[10]   Initial stability and bone strain evaluation of the immediately loaded dental implant: an in vitro model study [J].
Huang, Heng-Li ;
Chang, Yin-Yu ;
Lin, Dan-Jae ;
Li, Yu-Fen ;
Chen, Kuan-Ting ;
Hsu, Jui-Ting .