Naphthalimide trifluoroacetyl acetonate: a hydrazine-selective chemodosimetric sensor

被引:194
作者
Lee, Min Hee [1 ]
Yoon, Byungkwon [2 ]
Kim, Jong Seung [2 ]
Sessler, Jonathan L. [1 ,3 ]
机构
[1] Univ Texas Austin, Dept Chem & Biochem, Austin, TX 78712 USA
[2] Korea Univ, Dept Chem, Seoul 136701, South Korea
[3] Yonsei Univ, Dept Chem, Seoul 120749, South Korea
基金
美国国家科学基金会; 新加坡国家研究基金会;
关键词
TRACE HYDRAZINE; FLUORESCENT; CHEMOSENSORS; METHODOLOGY; OXIDATION; PROBE; WATER;
D O I
10.1039/c3sc51813b
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The trifluoroacetyl acetonate naphthalimide derivative 1 has been synthesized in good yield. In acetonitrile solution, compound 1 reacts selectively with hydrazine (NH2NH2) to give a five-membered ring. This leads to OFF-ON fluorescence with a maximum intensity at 501 nm as well as easily discernible color changes. Based on a readily discernible and reproducible 3.9% change in overall fluorescence intensity, the limit of detection for 1 is 3.2 ppb (0.1 mu M), which is below the accepted limit for hydrazine set by the U.S. Environmental Protection Agency (EPA). Compound 1 is selective for hydrazine over other amines, including NH4OH, NH2OH, ethylenediamine, methylamine, n-butylamine, piperazine, dimethylamine, triethylamine, pyridine, and is not perturbed by environmentally abundant metal ions. When supported on glass-backed silica gel TLC plates, compound 1 acts as a fluorimetric and colorimetric probe for hydrazine vapor at a partial pressure of 9.0 mm Hg, with selectivity over other potentially interfering volatile analytes, including ammonia, methylamine, n-butylamine, formaldehyde, acetaldehyde, H2O2, HCl, and CO2 being observed. Probe 1 can also be used for the detection of hydrazine in HeLa cells and does so without appreciable interference from other biologically abundant amines and metal ions.
引用
收藏
页码:4121 / 4126
页数:6
相关论文
共 40 条
[1]  
Anastas P.T., 1998, Green chemistry: theory and practice
[2]   Green chemistry and the role of analytical methodology development [J].
Anastas, PT .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1999, 29 (03) :167-175
[3]  
Andriès V, 2000, MATER PERFORMANCE, V39, P58
[4]  
[Anonymous], 1999, INT RISK INF SYST IR
[5]  
Beer PD, 2001, ANGEW CHEM INT EDIT, V40, P486, DOI 10.1002/1521-3773(20010202)40:3<486::AID-ANIE486>3.0.CO
[6]  
2-P
[7]  
Buffle J., 2001, SITU MONITORING AQUA
[8]   Biosensors and chemosensors based on the optical responses of polydiacetylenes [J].
Chen, Xiaoqiang ;
Zhou, Guodong ;
Peng, Xiaojun ;
Yoon, Juyoung .
CHEMICAL SOCIETY REVIEWS, 2012, 41 (13) :4610-4630
[9]   Sensitive and selective fluorescence determination of trace hydrazine in aqueous solution utilizing 5-chlorosalicylaldehyde [J].
Chen, Xiaotong ;
Xiang, Yu ;
Li, Zifan ;
Tong, Aijun .
ANALYTICA CHIMICA ACTA, 2008, 625 (01) :41-46
[10]   Modern reaction-based indicator systems [J].
Cho, Dong-Gyu ;
Sessler, Jonathan L. .
CHEMICAL SOCIETY REVIEWS, 2009, 38 (06) :1647-1662