OCT en-face images from the retina with adjustable depth resolution in real time

被引:41
作者
Podoleanu, AG [1 ]
Rogers, JA [1 ]
Jackson, DA [1 ]
机构
[1] Univ Kent, Sch Phys Sci, Appl Opt Grp, Canterbury CT2 7NR, Kent, England
基金
英国工程与自然科学研究理事会;
关键词
fiber-optic instrumentation; human eye; medical imaging; ophthalmoscope; optical coherence tomography; tomography;
D O I
10.1109/2944.796344
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A source with adjustable coherence length is devised and used to illuminate an OCT for en-face imaging of the retina of the human eye in vivo. Two modes of operation are described. The added capability of adjusting the depth resolution in real time while imaging patients is discussed. The utility of the OCT err-face imaging with adjustable coherence length for diagnostic is illustrated by images taken from the eye of a volunteer. Similar images with those produced by scanning laser ophthalmoscopes are produced for the first time in real time using OCT.
引用
收藏
页码:1176 / 1184
页数:9
相关论文
共 21 条
  • [1] [Anonymous], 1990, CONFOCAL MICROSCOPY
  • [2] *ANSI, 1986, 1361 ANSI Z
  • [3] AXIAL INTENSITY DISTRIBUTION ANALYSIS OF THE HUMAN RETINA WITH A CONFOCAL SCANNING LASER TOMOGRAPH
    BARTSCH, DU
    FREEMAN, WR
    [J]. EXPERIMENTAL EYE RESEARCH, 1994, 58 (02) : 161 - 173
  • [4] Self-phase-modulated Kerr-lens mode-locked Cr:forsterite laser source for optical coherence tomography
    Bouma, BE
    Tearney, GJ
    Bilinsky, IP
    Golubovic, B
    Fujimoto, JG
    [J]. OPTICS LETTERS, 1996, 21 (22) : 1839 - 1841
  • [5] SPECTRAL REFLECTANCE OF THE HUMAN OCULAR FUNDUS
    DELORI, FC
    PFLIBSEN, KP
    [J]. APPLIED OPTICS, 1989, 28 (06) : 1061 - 1077
  • [6] Fercher A F, 1996, J Biomed Opt, V1, P157, DOI 10.1117/12.231361
  • [7] IMAGE-FORMATION IN A FIBEROPTIC CONFOCAL SCANNING MICROSCOPE
    GU, M
    SHEPPARD, CJR
    GAN, X
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1991, 8 (11): : 1755 - 1761
  • [8] Dispersion induced multiple signal peak splitting in partial coherence interferometry
    Hitzenberger, CK
    Baumgartner, A
    Fercher, AF
    [J]. OPTICS COMMUNICATIONS, 1998, 154 (04) : 179 - 185
  • [9] OPTICAL COHERENCE TOMOGRAPHY
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    STINSON, WG
    CHANG, W
    HEE, MR
    FLOTTE, T
    GREGORY, K
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. SCIENCE, 1991, 254 (5035) : 1178 - 1181
  • [10] *HUMPHR INSTR, 1996, OPT COH TOM