2H NMR and 13C-IRMS analyses of acetic acid from vinegar, 18O-IRMS analysis of water in vinegar: International collaborative study report

被引:40
作者
Thomas, Freddy [1 ]
Jamin, Eric [1 ]
机构
[1] Eurofins Sci Analyt, F-44323 Nantes, France
关键词
Vinegar; Authenticity; SNIF-NMR; IRMS; Deuterium; Carbon; 13; Oxygen; 18; PROTOCOL;
D O I
10.1016/j.aca.2009.07.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An international collaborative study of isotopic methods applied to control the authenticity of vinegar was organized in order to support the recognition of these procedures as official methods. The determination of the H-2/H-1 ratio of the methyl site of acetic acid by SNIF-NMR (site-specific natural isotopic fractionation-nuclear magnetic resonance) and the determination of the C-13/C-12 ratio, by IRMS (isotope ratio mass spectrometry) provide complementary information to characterize the botanical origin of acetic acid and to detect adulterations of vinegar using synthetic acetic acid. Both methods use the same initial steps to recover pure acetic acid from vinegar. In the case of wine vinegar, the determination of the O-18/O-16 ratio of water by IRMS allows to differentiate wine vinegar from vinegars made from dried grapes. The same set of vinegar samples was used to validate these three determinations. The precision parameters of the method for measuring delta C-13 (carbon isotopic deviation) were found to be similar to the values previously obtained for similar methods applied to wine ethanol or sugars extracted from fruit juices: the average repeatability (r) was 0.45 parts per thousand, and the average reproducibility (R) was 0.91 parts per thousand. As expected from previous in-house study of the uncertainties, the precision parameters of the method for measuring the H-2/H-1 ratio of the methyl site were found to be slightly higher than the values previously obtained for similar methods applied to wine ethanol or fermentation ethanol in fruit juices: the average repeatability was 1.34 ppm, and the average reproducibility was 1.62 ppm. This precision is still significantly smaller than the differences between various acetic acid sources (delta C-13 and delta O-13) and allows a satisfactory discrimination of vinegar types. The precision parameters of the method for measuring delta O-13 were found to be similar to the values previously obtained for other methods applied to wine and fruit juices: the average repeatability was 0.15 parts per thousand., and the average reproducibility was 0.59 parts per thousand. The above values are proposed as repeatability and reproducibility limits in the current state of the art. On the basis of this satisfactory inter-laboratory precision and on the accuracy demonstrated by a spiking experiment, the authors recommend the adoption of the three isotopic determinations included in this study as official methods for controlling the authenticity of vinegar. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:98 / 105
页数:8
相关论文
共 7 条
[1]  
*AFNOR, 1993, V63001 NF AFNOR
[2]   PROTOCOL FOR THE DESIGN, CONDUCT AND INTERPRETATION OF METHOD-PERFORMANCE STUDIES [J].
HORWITZ, W .
PURE AND APPLIED CHEMISTRY, 1995, 67 (02) :331-343
[3]  
*INT ORG STAND, 57251994 ISO
[4]   A COUPLED NMR AND MS ISOTOPIC METHOD FOR THE AUTHENTICATION OF NATURAL VINEGARS [J].
REMAUD, G ;
GUILLOU, C ;
VALLET, C ;
MARTIN, GJ .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (4-5) :457-461
[5]   The International Harmonized Protocol for the proficiency testing of analytical chemistry laboratories (IUPAC technical report) [J].
Thompson, M ;
Ellison, SLR ;
Wood, R .
PURE AND APPLIED CHEMISTRY, 2006, 78 (01) :145-196
[6]  
VALLET C, 1988, Biotechnology Techniques, V2, P83, DOI 10.1007/BF01876155
[7]  
VERSINI G, 2006, ATT 6 C NAZ CHIM AL, P549