Standard versus hypofractionated intensity-modulated radiotherapy for prostate cancer: assessing the impact on dose modulation and normal tissue effects when using patient-specific cancer biology

被引:3
|
作者
Her, E. J. [1 ]
Ebert, M. A. [1 ,2 ,3 ]
Kennedy, A. [2 ]
Reynolds, H. M. [4 ]
Sun, Y. [5 ]
Williams, S. [4 ,6 ]
Haworth, A. [5 ]
机构
[1] Univ Western Australia, Sch Phys Math & Comp, Perth, WA, Australia
[2] Sir Charles Gairdner Hosp, Dept Radiat Oncol, Perth, WA, Australia
[3] 5D Clin, Perth, WA, Australia
[4] Univ Melbourne, Sir Peter MacCallum Dept Oncol, Melbourne, Vic, Australia
[5] Univ Sydney, Inst Med Phys, Sydney, NSW, Australia
[6] Peter MacCallum Canc Ctr, Div Radiat Oncol, Melbourne, Vic, Australia
基金
英国医学研究理事会;
关键词
prostate cancer; hypofractionation; tumour control probability; IMRT; multiparametric MRI;
D O I
10.1088/1361-6560/ab9354
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Hypofractionation of prostate cancer radiotherapy achieves tumour control at lower total radiation doses, however, increased rectal and bladder toxicities have been observed. To realise the radiobiological advantage of hypofractionation whilst minimising harm, the potential reduction in dose to organs at risk was investigated for biofocused radiotherapy. Patient-specific tumour location and cell density information were derived from multiparametric imaging. Uniform-dose plans and biologically-optimised plans were generated for a standard schedule (78 Gy/39 fractions) and hypofractionated schedules (60 Gy/20 fractions and 36.25 Gy/5 fractions). Results showed that biologically-optimised plans yielded statistically lower doses to the rectum and bladder compared to isoeffective uniform-dose plans for all fractionation schedules. A reduction in the number of fractions increased the target dose modulation required to achieve equal tumour control. On average, biologically-optimised, moderately-hypofractionated plans demonstrated 15.3% (p-value: <0.01) and 23.8% (p-value: 0.02) reduction in rectal and bladder dose compared with standard fractionation. The tissue-sparing effect was more pronounced in extreme hypofractionation with mean reduction in rectal and bladder dose of 43.3% (p-value: < 0.01) and 41.8% (p-value: 0.02), respectively. This study suggests that the ability to utilise patient-specific tumour biology information will provide greater incentive to employ hypofractionation in the treatment of localised prostate cancer with radiotherapy. However, to exploit the radiobiological advantages given by hypofractionation, greater attention to geometric accuracy is required due to increased sensitivity to treatment uncertainties.
引用
收藏
页数:16
相关论文
共 46 条
  • [41] Early results of urethral dose reduction and small safety margin in intensity-modulated radiation therapy (IMRT) for localized prostate cancer using a real-time tumor-tracking radiotherapy (RTRT) system
    Shinichi Shimizu
    Kentaro Nishioka
    Ryusuke Suzuki
    Nobuo Shinohara
    Satoru Maruyama
    Takashige Abe
    Rumiko Kinoshita
    Norio Katoh
    Rikiya Onimaru
    Hiroki Shirato
    Radiation Oncology, 9
  • [42] HELICAL TOMOTHERAPY VS. INTENSITY-MODULATED PROTON THERAPY FOR WHOLE PELVIS IRRADIATION IN HIGH-RISK PROSTATE CANCER PATIENTS: DOSIMETRIC, NORMAL TISSUE COMPLICATION PROBABILITY, AND GENERALIZED EQUIVALENT UNIFORM DOSE ANALYSIS
    Widesott, Lamberto
    Pierelli, Alessio
    Fiorino, Claudio
    Lomax, Antony J.
    Amichetti, Maurizio
    Cozzarini, Cesare
    Soukup, Martin
    Schneider, Ralf
    Hug, Eugen
    Di Muzio, Nadia
    Calandrino, Riccardo
    Schwarz, Marco
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (05): : 1589 - 1600
  • [43] Early results of urethral dose reduction and small safety margin in intensity-modulated radiation therapy (IMRT) for localized prostate cancer using a real-time tumor-tracking radiotherapy (RTRT) system
    Shimizu, Shinichi
    Nishioka, Kentaro
    Suzuki, Ryusuke
    Shinohara, Nobuo
    Maruyama, Satoru
    Abe, Takashige
    Kinoshita, Rumiko
    Katoh, Norio
    Onimaru, Rikiya
    Shirato, Hiroki
    RADIATION ONCOLOGY, 2014, 9
  • [44] Preliminary patient-reported outcomes analysis of 3-dimensional radiation therapy versus intensity-modulated radiation therapy on the high-dose arm of the Radiation Therapy Oncology Group (RTOG) 0126 prostate cancer trial
    Bruner, Deborah W.
    Hunt, Daniel
    Michalski, Jeff M.
    Bosch, Walter R.
    Galvin, James M.
    Amin, Mahul
    Xiao, Canhua
    Bahary, Jean-Paul
    Patel, Malti
    Chafe, Susan
    Rodrigues, George
    Lau, Harold
    Duclos, Marie
    Baikadi, Madhava
    Deshmukh, Snehal
    Sandler, Howard M.
    CANCER, 2015, 121 (14) : 2422 - 2430
  • [45] Comparison of acute and subacute genitourinary and gastrointestinal adverse events of radiotherapy for prostate cancer using intensity-modulated radiation therapy, three-dimensional conformal radiation therapy, permanent implant brachytherapy and high-dose-rate brachytherapy
    Morimoto, Masahiro
    Yoshioka, Yasuo
    Konishi, Koji
    Isohashi, Fumiaki
    Takahashi, Yutaka
    Ogata, Toshiyuki
    Koizumi, Masahiko
    Teshima, Teruki
    Bijl, Henk P.
    van der Schaaf, Arjen
    Langendijk, Johannes A.
    Ogawa, Kazuhiko
    TUMORI, 2014, 100 (03) : 265 - 271
  • [46] MRI before and after external beam intensity-modulated radiotherapy of patients with prostate cancer: The feasibility of monitoring of radiation-induced tissue changes using a dynamic contrast-enhanced inversion-prepared dual-contrast gradient echo sequence
    Franiel, Tobias
    Luedemann, Lutz
    Taupitz, Matthias
    Boehmer, Dirk
    Beyersdorff, Dirk
    RADIOTHERAPY AND ONCOLOGY, 2009, 93 (02) : 241 - 245