The effectiveness of a hands-free environmental control system for the profoundly disabled

被引:40
|
作者
Craig, A
Moses, P
Tran, Y
McIsaac, P
Kirkup, L
机构
[1] Univ Technol Sydney, Dept Hlth Sci, Sydney, NSW 2007, Australia
[2] Univ Technol Sydney, Dept Appl Phys, Sydney, NSW 2007, Australia
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2002年 / 83卷 / 10期
关键词
disabled persons; electroencephalography; environment; controlled; rehabilitation;
D O I
10.1053/apmr.2002.34624
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To investigate the effectiveness of a hands-free environmental control system.(ECS) that allows profoundly disabled persons to activate and control electric devices in their home by using consciously controlled changes in their brain signals. Design: A cohort study with a field trial testing of the ECS on 3 occasions. Setting: Participants' homes. Participants: Ten profoundly disabled persons (mean age, 42.9y), all of whom had very limited movement from the neck downward. Six had spinal cord injury with lesions ranging from C2 to C5-6. The other 4 had profound disability (1 each from polio, spinal muscular atrophy, multiple sclerosis, cerebral palsy). Interventions: Participants performed tasks on each of 3 test occasions. The tasks consisted of turning a television on at the beginning of the trial, changing channels (up, down), changing volume, and turning it off at the conclusion of each trial. Main Outcome Measures: Time participants took to select the correct option and number of errors made in selecting the correct option. Measures were taken for each trial, so that any improvement in switching could be detected. Results: All participants effectively used the ECS to operate their television sets. Selecting a correct option took about 30 seconds (with the majority of this time attributed to machine cycling time), with an error rate of 1.8 per 5 options selected. The time taken to operate the ECS reduced slightly over the 3 trials and selection errors reduced by around 50% (to less than 1 error per 5 options). Conclusions: With minimal training, profoundly disabled persons were able to use an ECS that uses changes in brain wave signals. This result demonstrates the efficacy of an additional and novel ECS in an area in which few switches are available.
引用
收藏
页码:1455 / 1458
页数:4
相关论文
共 23 条
  • [1] Electromyographic control of a hands-free electrolarynx using neck strap muscles
    Kubert, Heather L.
    Stepp, Cara E.
    Zeitels, Steven M.
    Gooey, John E.
    Walsh, Michael J.
    Prakash, S. R.
    Hillman, Robert E.
    Heaton, James T.
    JOURNAL OF COMMUNICATION DISORDERS, 2009, 42 (03) : 211 - 225
  • [2] Feedback Control of an Exoskeleton for Paraplegics TOWARD ROBUSTLY STABLE, HANDS-FREE DYNAMIC WALKING
    Harib, Omar
    Hereid, Ayonga
    Agrawal, Ayush
    Gurriet, Thomas
    Finet, Sylvain
    Boeris, Guilhem
    Duburcq, Alexis
    Mungai, M. Eva
    Masselin, Matthieu
    Ames, Aaron D.
    Sreenath, Koushil
    Grizzle, Jessy W.
    IEEE CONTROL SYSTEMS MAGAZINE, 2018, 38 (06): : 61 - 87
  • [3] A Hands-free Interface for Controlling Virtual Electric-powered Wheelchairs
    Gulrez, Tauseef
    Tognetti, Alessandro
    Yoon, Woon Jong
    Kavakli, Manolya
    Cabibihan, John-John
    INTERNATIONAL JOURNAL OF ADVANCED ROBOTIC SYSTEMS, 2016, 13
  • [4] The significance of uprightness: parents' reflections on children's responses to a hands-free walker for children
    McKeever, P.
    Rossen, B. E.
    Scott, H.
    Robinson-Vincent, K.
    Wright, V.
    DISABILITY & SOCIETY, 2013, 28 (03) : 380 - 392
  • [5] Hands-free Atalante exoskeleton in post-stroke gait and balance rehabilitation: a safety study
    Thierry Lejeune
    Dijana Nuic
    Stéphanie Dehem
    Jean-Gabriel Previnaire
    Céline Cuenot
    Thierry Debugne
    Jerome Kaps
    Bérénice Paul
    Vincent Pean
    Sergi Sanz Perez
    Fanny Juhel
    Soultana Tatsidou
    Jacques Kerdraon
    Journal of NeuroEngineering and Rehabilitation, 22 (1)
  • [6] TRACHEOSTOMAPLASTY: A SURGICAL METHOD FOR IMPROVING RETENTION OF AN INTRALUMINAL STOMA BUTTON FOR HANDS-FREE TRACHEOESOPHAGEAL SPEECH
    Moreno, Mauricio A.
    Lewin, Jan S.
    Hutcheson, Katherine A.
    Leone, Julie K. Bishop
    Barringer, Denise A.
    Reece, Gregory P.
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2010, 32 (12): : 1674 - 1680
  • [7] Close speaker cancellation for suppression of non-stationary background noise for hands-free speech interface
    Even, Jani
    Ishi, Carlos
    Saruwatari, Hiroshi
    Hagita, Norihiro
    11TH ANNUAL CONFERENCE OF THE INTERNATIONAL SPEECH COMMUNICATION ASSOCIATION 2010 (INTERSPEECH 2010), VOLS 1-2, 2010, : 977 - 980
  • [8] A new custom moldable external neck brace (ENB 2.0) to improve hands-free speech in laryngectomized patients
    Dirven, Richard
    Clark, Jonathan R.
    Wismans, Joris G. F.
    McGuiness, John
    Palme, Carsten E.
    Blyth, Katrina
    Baxter, Candice
    Stone, Danielle B.
    Marres, Henri A. M.
    LARYNGOSCOPE, 2013, 123 (09): : 2209 - 2215
  • [9] Sublime: a Hands-Free Virtual Reality Menu Navigation System Using a High-Frequency SSVEP-based Brain-Computer Interface
    Armengol-Urpi, Alexandre
    Sarma, Sanjay E.
    24TH ACM SYMPOSIUM ON VIRTUAL REALITY SOFTWARE AND TECHNOLOGY (VRST 2018), 2018,
  • [10] Three-dimensional stereophotogrammetrical analysis of peristomal fixation of adhesive base plates during hands-free speech among laryngectomised patients related to tracheostoma volumes
    Dirven, R.
    Wouters, Y.
    Vreeken, R.
    Maal, T. J. J.
    Marres, H. A. M.
    CLINICAL OTOLARYNGOLOGY, 2012, 37 (02) : 124 - 129