A biomechanical comparison of two plating techniques in lateral clavicle fractures

被引:3
|
作者
Suter, Cyrill [1 ]
von Rohr, Martina [1 ]
Majewski, Martin [1 ]
Duerselen, Lutz [2 ]
Warnecke, Daniela [2 ]
Schild, Natalie [2 ]
Nowakowski, Andrej Maria [1 ,3 ]
机构
[1] Univ Basel, Med Fac, Klingelbergstr 61, CH-4056 Basel, Switzerland
[2] Ulm Univ, Med Ctr, Trauma Res Ctr Ulm, Inst Orthoped Res & Biomech, Helmholtzstr 14, D-89081 Ulm, Germany
[3] Spital Uster, Orthoped Dept, Brunnenstr 42, CH-8610 Uster, Switzerland
关键词
Lateral clavicle fracture; Biomechanical testing; Plate fixation; Single plate; Double plate; Surgical treatment; DISTAL CLAVICLE; SURGICAL-TREATMENT; TISSUE DIFFERENTIATION; FIXATION; LOCKING; STABILITY; EPIDEMIOLOGY; STIFFNESS; END; VASCULARIZATION;
D O I
10.1016/j.clinbiomech.2019.05.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Neer Type fib lateral clavicle fractures typically lead to dislocation of the medial fragment. Therefore, most surgeons recommend surgical treatment for such a fracture pattern. The use of a locking compression plate with a lateral extension has produced satisfactory results in various studies over recent years. Double-plate fixation is a common technique in the treatment of complex distal radius fractures. The authors use this technique as a routine procedure in the treatment of Neer type IIb fractures. In this biomechanical testing study, the mechanical properties of the two techniques were compared. Methods: On 20 clavicles from fresh frozen cadavers a Neer Type IIb fracture-like osteotomy was performed. A cyclic loading test followed by a load-to-failure test was carried out. Parameters for statistical evaluation were the stiffness at cycles 1, 100 and 17,500 as well as the ultimate tensile load and the deformation at the point of failure. Findings: All specimens withstood the cyclic loading test without any noticeable damage. At cycles 100 and 17,500, the double-plate technique was less stiff. Failure loads were not significantly different from each other, but deformation at the point of failure was significantly greater for the double-plate technique. Interpretation: Both techniques provided sufficient fixation to the fracture site to endure the cyclic loading test, which is supposed to simulate an incident-free week postoperatively. In summary, the double-plate technique offers biomechanically a feasible alternative to the single-plate technique in lateral clavicle fractures of Neer Type IIb.