Numerical verification for a new type of UV disinfection reactor

被引:7
|
作者
Pan, Yupeng [1 ]
Tian, Xiaoqing [1 ,2 ]
Zhang, Baofeng [3 ]
Zhu, Zefei [1 ]
Pan, Huachen [1 ]
Rahman, M. M. [1 ]
Leng, Jianxing [2 ]
机构
[1] Hangzhou Dianzi Univ, Sch Mech Engn, Hangzhou 310018, Peoples R China
[2] Zhejiang Univ, Ocean Coll, Zhoushan 316021, Peoples R China
[3] Hangzhou Environm Monitoring Ctr, Hangzhou 310010, Peoples R China
基金
中国国家自然科学基金;
关键词
CFD; UV disinfection reactor; UV dose; H2O2; WATER; PERFORMANCE; RADIATION; FLOW; LAMP; PHARMACEUTICALS; INACTIVATION; DEGRADATION; IMPACT; CFD;
D O I
10.1016/j.asej.2020.03.014
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The traditional biological method applied to the CFD (Computational Fluid Dynamics) analyses of ultraviolet (UV) disinfection reactor associates problems such as the long experimental period and complicated process. However, the paper proposes a CFD verification for a new UV disinfection reactor. The UV dose of UV disinfection reactor in different inlet flow rates and diverse UV powers are simulated and analyzed by the ANSYS-Fluent; a separate Fortran program is made for UV dose calculations. The H2O2 solution is added to the reactor model for the center dot OH(hydroxyl radical)absorbance experiment and numerical results of reactor are evaluated. It is concluded that the method of detecting center dot OH absorbance photolysis products by imposing H2O2 solution can verify the accuracy of CFD simulation. It can be applied to the design process of UV disinfection equipment. The radiation intensity near the light source is the strongest parameter. With an increase of radial distance, the UV light intensity shows an exponential decay. The UV dose can be increased by reducing the inlet flow and increasing the lamp power. However, results indicate that the adjustment of flow rate at the entrance is superior to increasing the power of UV lamp. (C) 2020 The Authors. Published by Elsevier B.V. on behalf of Faculty of Engineering, Ain Shams University.
引用
收藏
页码:1191 / 1200
页数:10
相关论文
共 50 条
  • [21] A New Colored Beverage Disinfection System Using UV-A Light-Emitting Diodes
    Lian, Xin
    Tetsutani, Kayo
    Katayama, Mai
    Nakano, Masayuki
    Mawatari, Kazuaki
    Harada, Nagakatsu
    Hamamoto, Akiko
    Yamato, Masayuki
    Akutagawa, Masatake
    Kinouchi, Yohsuke
    Nakaya, Yutaka
    Takahashi, Akira
    BIOCONTROL SCIENCE, 2010, 15 (01) : 33 - 37
  • [22] Prediction of the effects of vortex shedding on UV disinfection efficiency
    Younis, B. A.
    Yang, T. H.
    JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA, 2011, 60 (03): : 147 - 158
  • [23] UV surface disinfection in a wearable drug delivery device
    Zrehen, Adam
    Hili, Uri
    Weil, Noam
    Ben-David, Ori
    Yosef, Andrei
    Eitan, Boaz
    BIOMEDICAL OPTICS EXPRESS, 2022, 13 (04) : 2144 - 2155
  • [24] The assessment of particle association and UV disinfection of wastewater using indigenous spore-forming bacteria
    Li, Dong
    Craik, Stephen A.
    Smith, Daniel W.
    Belosevic, Miodraq
    WATER RESEARCH, 2009, 43 (02) : 481 - 489
  • [25] Solar Water Disinfection: UV Radiation Transmittance of Various Solar Reactor Tubes
    Ayoub, George M.
    Malaeb, Lilian
    TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY (TMREES), 2019, 157 : 498 - 511
  • [26] Computational analysis of three lamp close conduit water disinfection UV reactor
    T. Sultan
    Z. Ahmad
    K. Hayat
    I. A. Chaudhry
    International Journal of Environmental Science and Technology, 2022, 19 : 4393 - 4406
  • [27] Improving UV seawater disinfection with immobilized TiO2: Study of the viability of photocatalysis (UV254/TiO2) as seawater disinfection technology
    Rubio, D.
    Casanueva, J. F.
    Nebot, E.
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2013, 271 : 16 - 23
  • [28] Numerical simulation of UV disinfection reactors: Evaluation of alternative turbulence models
    Liu, Dong
    Wu, Chin
    Linden, Karl
    Ducoste, Joel
    APPLIED MATHEMATICAL MODELLING, 2007, 31 (09) : 1753 - 1769
  • [29] UV-C Disinfection and Impact on the Quality of Black, White, Green, and Pink Peppercorns Using a Scalable Reactor
    Arcos-Liminana, Victor
    Brunet, Carlotta
    Prats-Moya, Maria Soledad
    Maestre-Perez, Salvador
    FOOD AND BIOPROCESS TECHNOLOGY, 2025,
  • [30] Virus Sensitivity Index of UV disinfection
    Tang, Walter Z.
    Sillanpaa, Mika
    ENVIRONMENTAL TECHNOLOGY, 2015, 36 (11) : 1464 - 1475