Numerical verification for a new type of UV disinfection reactor

被引:7
|
作者
Pan, Yupeng [1 ]
Tian, Xiaoqing [1 ,2 ]
Zhang, Baofeng [3 ]
Zhu, Zefei [1 ]
Pan, Huachen [1 ]
Rahman, M. M. [1 ]
Leng, Jianxing [2 ]
机构
[1] Hangzhou Dianzi Univ, Sch Mech Engn, Hangzhou 310018, Peoples R China
[2] Zhejiang Univ, Ocean Coll, Zhoushan 316021, Peoples R China
[3] Hangzhou Environm Monitoring Ctr, Hangzhou 310010, Peoples R China
基金
中国国家自然科学基金;
关键词
CFD; UV disinfection reactor; UV dose; H2O2; WATER; PERFORMANCE; RADIATION; FLOW; LAMP; PHARMACEUTICALS; INACTIVATION; DEGRADATION; IMPACT; CFD;
D O I
10.1016/j.asej.2020.03.014
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The traditional biological method applied to the CFD (Computational Fluid Dynamics) analyses of ultraviolet (UV) disinfection reactor associates problems such as the long experimental period and complicated process. However, the paper proposes a CFD verification for a new UV disinfection reactor. The UV dose of UV disinfection reactor in different inlet flow rates and diverse UV powers are simulated and analyzed by the ANSYS-Fluent; a separate Fortran program is made for UV dose calculations. The H2O2 solution is added to the reactor model for the center dot OH(hydroxyl radical)absorbance experiment and numerical results of reactor are evaluated. It is concluded that the method of detecting center dot OH absorbance photolysis products by imposing H2O2 solution can verify the accuracy of CFD simulation. It can be applied to the design process of UV disinfection equipment. The radiation intensity near the light source is the strongest parameter. With an increase of radial distance, the UV light intensity shows an exponential decay. The UV dose can be increased by reducing the inlet flow and increasing the lamp power. However, results indicate that the adjustment of flow rate at the entrance is superior to increasing the power of UV lamp. (C) 2020 The Authors. Published by Elsevier B.V. on behalf of Faculty of Engineering, Ain Shams University.
引用
收藏
页码:1191 / 1200
页数:10
相关论文
共 50 条
  • [1] Numerical simulation of the disinfection performance in an annular reactor with different internal configurations
    Long, Fei
    Deng, Baoqing
    Xu, Yuying
    Gao, Jing
    Zhang, Yujie
    JOURNAL OF WATER PROCESS ENGINEERING, 2019, 31
  • [2] Numerical study of the effects of surface roughness on water disinfection UV reactor
    Sultan, Tipu
    Ahmad, Sarfraz
    Cho, Jinsoo
    CHEMOSPHERE, 2016, 148 : 108 - 117
  • [3] Design optimization of a cylindrical UV-C LED reactor for effective water disinfection with numerical simulations and test reactor fabrication
    Kang, Seoyoung
    Bae, Jinseung
    Park, Sungsu
    Kim, Kyoungjun
    Lee, Junghun
    Yoon, Chulsoo
    Ryu, Changkook
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2024, 12 (02):
  • [4] Computational analysis of three lamp close conduit water disinfection UV reactor
    Sultan, T.
    Ahmad, Z.
    Hayat, K.
    Chaudhry, I. A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2022, 19 (05) : 4393 - 4406
  • [5] UV disinfection of water: the need for UV reactor validation
    Lawryshyn, YA
    Cairns, B
    WATER RECYCLING IN THE MEDITERRANEAN REGION, 2003, 3 (04): : 293 - 300
  • [6] Computational fluid dynamics (CFD) modeling of UV disinfection in a closed-conduit reactor
    Chen, Jieyong
    Deng, Baoqing
    Kim, Chang Nyung
    CHEMICAL ENGINEERING SCIENCE, 2011, 66 (21) : 4983 - 4990
  • [7] Numerical and experimental investigation of UV disinfection for water treatment
    Li, H. Y.
    Osman, H.
    Kang, C. W.
    Ba, T.
    APPLIED THERMAL ENGINEERING, 2017, 111 : 280 - 291
  • [8] Similitude in an Open-Channel UV Wastewater Disinfection Reactor
    Saha, Rajib Kumar
    Zhang, Chao
    Ray, Madhumita B.
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2015, 141 (03)
  • [9] Numerical study of the effects of lamp configuration and reactor wall roughness in an open channel water disinfection UV reactor
    Sultan, Tipu
    CHEMOSPHERE, 2016, 155 : 170 - 179
  • [10] Numerical and experimental studies of water disinfection in UV reactors
    Li, H. Y.
    Osman, H.
    Kang, C. W.
    Ba, T.
    Lou, J.
    WATER SCIENCE AND TECHNOLOGY, 2019, 80 (08) : 1456 - 1465