Intraarticular migration of a broken biodegradable interference screw after anterior cruciate ligament reconstruction

被引:47
|
作者
Baums, M. H.
Zelle, B. A.
Schultz, W.
Ernstberger, T.
Klinger, H. -M.
机构
[1] Univ Gottingen, Dept Orthopaed Surg, D-37075 Gottingen, Germany
[2] Univ Pittsburgh, Med Ctr, Dept Orthopaed Surg, Pittsburgh, PA USA
关键词
bioabsorbable interference screw; anterior cruciate ligament reconstruction; complication; intraarticular migration;
D O I
10.1007/s00167-006-0049-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Poly-L-lactic acid biodegradable screws have been used effectively for graft fixation in anterior cruciate ligament (ACL) reconstruction. The overall complication rate associated with the use of this implant is low, although some authors reported complications, such as osteolysis and aseptic effusion of the knee joint. We report a case of a 29-year-old female patient with a failure of a biodegradable interference screw at 22 months after ACL reconstruction using bone-patellar tendon-bone graft. In this illustrated case, the screw broke and migrated into the knee joint. In addition, we performed a detailed review of the medical literature from 1990-2005 to identify possible causes of biodegradable screw failures. We identified six published cases of bioabsorbable interference screw failure with migration into the knee joint. Several authors have reported small diameter of the screw, poor bone quality, bone resorption, and screw divergence as potential causes for intraarticular migration of metallic interference screws. With regard to bioscrews, no specific risk factors for screw breakage and intraarticular migration have been reported. ACL reconstruction with the use of bioabsorbable interference screws for fixation is considered to be reliable. However, we need to be aware of potential problems associated with the use of this implant. Early recognition of bioscrew failure may prevent associated morbidities, such as subsequent cartilage damage.
引用
收藏
页码:865 / 868
页数:4
相关论文
共 50 条
  • [31] POSTERIOR CRUCIATE LIGAMENT RECONSTRUCTION •• ARE THE RESULTS SIMILAR TO ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION?
    Mestriner, Marcos Barbieri
    Hirosse, Fabio Eidi
    dos Anjos Rabelo, Nayra Deise
    dos Santos Netto, Alfredo
    de Oliveira, Victor Marques
    de Paula Leite Cury, Ricardo
    ACTA ORTOPEDICA BRASILEIRA, 2023, 31 (02):
  • [32] Broken Delta interference screw after ACL reconstruction: a report of two cases
    Bollen, S. M.
    van der Hoeven, H.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (09) : 903 - 906
  • [33] Broken Delta interference screw after ACL reconstruction: a report of two cases
    S. M. Bollen
    H. van der Hoeven
    Knee Surgery, Sports Traumatology, Arthroscopy, 2006, 14 : 903 - 906
  • [34] Bioabsorbable polyglyconate interference screw fixation in anterior cruciate ligament reconstruction: A prospective computed tomography-controlled study
    Fink, C
    Benedetto, KP
    Hackl, W
    Hoser, C
    Freund, MC
    Rieger, M
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2000, 16 (05) : 491 - 498
  • [35] Interference screw versus Endoscrew fixation for anterior cruciate ligament reconstruction: A biomechanical comparative study in sawbones and porcine knees
    Hung, Chu-Chih
    Chen, Wen-Chuan
    Yang, Chan-Tsung
    Cheng, Cheng-Kung
    Chen, Chih-Hwa
    Lai, Yu-Shu
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2014, 2 (02) : 82 - 90
  • [36] Whether sutures reduce the graft laceration caused by interference screw in anterior cruciate ligament reconstruction? A biomechanical study in vitro
    Teng, Yuanjun
    Zhang, Xiaohui
    Da, Lijun
    Hu, Jie
    Wang, Hong
    Han, Hua
    Wu, Meng
    Zhang, Shifeng
    Xia, Yayi
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [37] Whether sutures reduce the graft laceration caused by interference screw in anterior cruciate ligament reconstruction? A biomechanical study in vitro
    Yuanjun Teng
    Xiaohui Zhang
    Lijun Da
    Jie Hu
    Hong Wang
    Hua Han
    Meng Wu
    Shifeng Zhang
    Yayi Xia
    BMC Musculoskeletal Disorders, 22
  • [38] Interference screw fixation of doubled flexor tendon graft in anterior cruciate ligament reconstruction - biomechanical evaluation with cyclic elongation
    Nakano, H
    Yasuda, K
    Tohyama, H
    Yamanaka, M
    Wada, T
    Kaneda, K
    CLINICAL BIOMECHANICS, 2000, 15 (03) : 188 - 195
  • [39] Gross Measurement of Intraarticular Graft Length in All-Inside Anterior Cruciate Ligament Reconstruction
    Koukoulias, Nikolaos E.
    V. Vasiliadis, Angelo
    Germanou, Evangelia
    Kannas, Theodoros M.
    Dimitriadis, Thefilos
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (03)
  • [40] Gait patterns before and after anterior cruciate ligament reconstruction
    Zsolt Knoll
    László Kocsis
    Rita M. Kiss
    Knee Surgery, Sports Traumatology, Arthroscopy, 2004, 12 : 7 - 14