Flow patterns and transitions in a rectangular three-phase bubble column

被引:28
|
作者
Li, Weiling [1 ]
Zhong, Wenqi [1 ]
Jin, Baosheng [1 ]
Lu, Yong [1 ]
He, Tingting [1 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Minist Educ, Key Lab Energy Thermal Convers & Control, Nanjing 210096, Jiangsu, Peoples R China
关键词
Flow pattern; Flow regime transition; Gas-liquid-solid flow; Particle effect; Three-phase bubble column; REGIME IDENTIFICATION; SOLIDS; TURBULENCE; BEHAVIOR; HOLDUP;
D O I
10.1016/j.powtec.2014.04.002
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The flow patterns and transitions in a rectangular gas-liquid-solid three-phase bubble column were studied. The influence of solid volume fraction, particle size and particle density on the flow regime transitions of the three-phase bubble column was investigated experimentally. Experiments were carried out for solid volume fraction V-s = 0.03-0.3, average particle size d(p) = 48 mu m-270 mu m, particle density rho(p) = 2500 kg/m(3)-4800 kg/m(3), and superficial gas velocity U-g = 0.007 m/s-0.7 m/s in a rectangular bubble column measured 0.8 m tall, 0.1 m long and 0.01 m wide. Four distinct flow patterns and three transition points were observed in this experimental system, and the four flow regimes were discrete bubble regime, transition regime, bubble coalescence regime and strong turbulent regime, which were determined on the basis of criteria as well as schematic diagrams and typical flow pattern images obtained from a high-resolution digital charge couple device (CCD) camera. Typical flow patterns maps were plotted for illustrating flow regime transitions under different particle conditions. It was found out that particle volume fraction and particle density had an effect on the flow pattern transitions; when increasing the values of particle volume fraction and the particle density respectively, the values of the flow regime transition points all decreased. Particle size had a little effect on flow regime transition points when the particle size shifted in the range of 48 mu m to 150 mu m; when particle size was larger than 150 mu m and increased to 270 mu m, the operation ranges of the transition regime and the bubble coalescence regime decreased. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:27 / 35
页数:9
相关论文
共 50 条
  • [1] CFD simulation of hydrodynamics of gas-liquid-solid three-phase bubble column
    Li, Weiling
    Zhong, Wenqi
    POWDER TECHNOLOGY, 2015, 286 : 766 - 788
  • [2] PDA measurements in a three-phase bubble column
    Gan, Z. W.
    Yu, S. C. M.
    Law, A. W. K.
    AICHE JOURNAL, 2013, 59 (07) : 2286 - 2307
  • [3] Effect of bubble-particle interaction models on flow predictions in three-phase bubble columns
    Gruber, Michael C.
    Radl, Stefan
    Khinast, Johannes G.
    CHEMICAL ENGINEERING SCIENCE, 2016, 146 : 226 - 243
  • [4] Flow regime transitions in a bubble column
    Medjiade, Willy Tchowa
    Rosenbaum Alvaro, Agustin
    Schumpe, Adrian
    CHEMICAL ENGINEERING SCIENCE, 2017, 170 : 263 - 269
  • [5] Calcium alginate beads motion in a foaming three-phase bubble column
    Salierno, Gabriel
    Maestri, Mauricio
    Piovano, Stella
    Cassanello, Miryan
    Angelica Cardona, Maria
    Hojman, Daniel
    Somacal, Hector
    CHEMICAL ENGINEERING JOURNAL, 2017, 324 : 358 - 369
  • [6] Three-dimensional simulation of a three-phase draft-tube bubble column
    Padial, NT
    VanderHeyden, WB
    Rauenzahn, RM
    Yarbro, SL
    CHEMICAL ENGINEERING SCIENCE, 2000, 55 (16) : 3261 - 3273
  • [7] Solid motion in a three-phase bubble column examined with Radioactive Particle Tracking
    Salierno, Gabriel
    Maestri, Mauricio
    Piovano, Stella
    Cassanello, Miryan
    Angelica Cardona, Maria
    Hojman, Daniel
    Somacal, Hector
    FLOW MEASUREMENT AND INSTRUMENTATION, 2018, 62 : 196 - 204
  • [8] Flow regime identification in a three-phase bubble column based on statistical, Hurst, Hilbert-Huang transform and Shannon entropy analysis
    Li, Wei-Ling
    Zhong, Wen-Qi
    Jin, Bao-Sheng
    Xiao, Rui
    He, Ting-Ting
    CHEMICAL ENGINEERING SCIENCE, 2013, 102 : 474 - 485
  • [9] Hydrodynamic study of three-phase flow in column flotation using electrical resistance tomography coupled with pressure transducers
    Vadlakonda, Balraju
    Mangadoddy, Narasimha
    SEPARATION AND PURIFICATION TECHNOLOGY, 2018, 203 : 274 - 288
  • [10] Impacts of Particle Properties on Gas Holdup under Four Flow Regimes in Three-Phase Bubble Columns
    Li, Weiling
    Zhou, Genfu
    Sun, Jian
    Guo, Yafei
    Wang, Ruilin
    CHEMICAL ENGINEERING & TECHNOLOGY, 2021, 44 (12) : 2347 - 2354