Simulation and Experimental Study on the Optical Performance of a Fixed-Focus Fresnel Lens Solar Concentrator Using Polar-Axis Tracking

被引:22
作者
Wang, Hai [1 ]
Huang, Jin [1 ]
Song, Mengjie [2 ]
Hu, Yanxin [1 ]
Wang, Yunfeng [3 ]
Lu, Zijian [1 ]
机构
[1] Guangdong Univ Technol, Sch Mat & Energy, Dept Energy Engn, Guangzhou 510006, Guangdong, Peoples R China
[2] Univ Tokyo, Grad Sch Frontier Sci, Dept Human & Engineered Environm Studies, Tokyo 2778563, Japan
[3] Yunnan Normal Univ, Solar Energy Res Inst, Kunming 650092, Yunnan, Peoples R China
基金
中国国家自然科学基金;
关键词
solar energy; fixed-focus; polar-axis tracking; Fresnel lens; optical efficiency; NUMERICAL-SIMULATION; DESIGN; SYSTEM; COLLECTOR; OPTIMIZATION; DESALINATION; FEASIBILITY; RADIATION; RECEIVER; PLATE;
D O I
10.3390/en11040887
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Most sun-tracking systems of solar concentrators are expensive, sensitive to operational costs, and complicated in optical design in which the receiver must be free to rotate about the axis. To overcome the aforementioned problems, this study presents a fixed-focus Fresnel lens solar concentrator (FFFSC) using polar-axis tracking which allows the Fresnel lens to concentrate sunlight to a fixed small heat-receiving area and the receiver remained fixed in location and rotation. Experimental research has been conducted to obtain the optical characteristics of the FFFSC for different solar times, tracking errors, and periodical adjustment errors. It has been found that maximum values of the relative optical efficiency loss (eta(re-opt,loss)) and minimum value of the optical efficiency (eta(opt)) of the FFFSC for different solar times are 1.87% and 71.61%, respectively. The mean value and maximum value of the local concentration ratio of the solar flux on the receiver are more than 86.64 and 1319.43, respectively. When the tracking error and periodical adjustment error are within 1 degrees, the eta(opt) of the FFFSC can reach 70.38% and 68.94%, respectively. The optical characteristics of FFFSC is also verified numerically. Especially, according to the total year simulation of the FFFSC's optical characteristics, maximum value of eta(re-opt),(loss) is 0.116%, which means the proposed the FFFSC can achieve fixed-focus.
引用
收藏
页数:16
相关论文
共 41 条
[1]   Simulation of a dual-axis solar tracker for improving the performance of a photovoltaic panel [J].
Alexandru, C. ;
Pozna, C. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2010, 224 (A6) :797-811
[2]   Prediction of monthly average global solar radiation based on statistical distribution of clearness index [J].
Ayodele, T. R. ;
Ogunjuyigbe, A. S. O. .
ENERGY, 2015, 90 :1733-1742
[3]  
Badescu V., 1994, International Journal of Solar Energy, V14, P203, DOI 10.1080/01425919408909811
[4]   Theoretical derivation of heliostat tracking errors distribution [J].
Badescu, Viorel .
SOLAR ENERGY, 2008, 82 (12) :1192-1197
[5]   Multi-criteria evaluation of a nanofluid-based linear Fresnel solar collector [J].
Bellos, Evangelos ;
Tzivanidis, Christos .
SOLAR ENERGY, 2018, 163 :200-214
[6]   Experimental and numerical investigation of a linear Fresnel solar collector with flat plate receiver [J].
Bellos, Evangelos ;
Mathioulakis, Emmanouil ;
Tzivanidis, Christos ;
Belessiotis, Vassilis ;
Antonopoulos, Kimon A. .
ENERGY CONVERSION AND MANAGEMENT, 2016, 130 :44-59
[7]   Impact of heliostat curvature on optical performance of Linear Fresnel solar concentrators [J].
Benyakhlef, S. ;
Al Mers, A. ;
Merroun, O. ;
Bouatem, A. ;
Boutammachte, N. ;
El Alj, S. ;
Ajdad, H. ;
Erregueragui, Z. ;
Zemmouri, E. .
RENEWABLE ENERGY, 2016, 89 :463-474
[8]   Optimization of the geometry of Fresnel linear collectors [J].
Boito, Paola ;
Grena, Roberto .
SOLAR ENERGY, 2016, 135 :479-486
[9]   An experimental study of the effect of exfoliated graphite solar coating with a sensible heat storage and Scheffler dish for desalination [J].
Chandrashekara, M. ;
Yadav, Avadhesh .
APPLIED THERMAL ENGINEERING, 2017, 123 :111-122
[10]   Characterization of Fresnel lens optical performances using an opal diffuser [J].
Chemisana, Daniel ;
Vossier, Alexis ;
Pujol, Loic ;
Perona, Arnaud ;
Dollet, Alain .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (01) :658-663