Simulation and Experimental Study on the Optical Performance of a Fixed-Focus Fresnel Lens Solar Concentrator Using Polar-Axis Tracking

被引:23
|
作者
Wang, Hai [1 ]
Huang, Jin [1 ]
Song, Mengjie [2 ]
Hu, Yanxin [1 ]
Wang, Yunfeng [3 ]
Lu, Zijian [1 ]
机构
[1] Guangdong Univ Technol, Sch Mat & Energy, Dept Energy Engn, Guangzhou 510006, Guangdong, Peoples R China
[2] Univ Tokyo, Grad Sch Frontier Sci, Dept Human & Engineered Environm Studies, Tokyo 2778563, Japan
[3] Yunnan Normal Univ, Solar Energy Res Inst, Kunming 650092, Yunnan, Peoples R China
基金
中国国家自然科学基金;
关键词
solar energy; fixed-focus; polar-axis tracking; Fresnel lens; optical efficiency; NUMERICAL-SIMULATION; DESIGN; SYSTEM; COLLECTOR; OPTIMIZATION; DESALINATION; FEASIBILITY; RADIATION; RECEIVER; PLATE;
D O I
10.3390/en11040887
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Most sun-tracking systems of solar concentrators are expensive, sensitive to operational costs, and complicated in optical design in which the receiver must be free to rotate about the axis. To overcome the aforementioned problems, this study presents a fixed-focus Fresnel lens solar concentrator (FFFSC) using polar-axis tracking which allows the Fresnel lens to concentrate sunlight to a fixed small heat-receiving area and the receiver remained fixed in location and rotation. Experimental research has been conducted to obtain the optical characteristics of the FFFSC for different solar times, tracking errors, and periodical adjustment errors. It has been found that maximum values of the relative optical efficiency loss (eta(re-opt,loss)) and minimum value of the optical efficiency (eta(opt)) of the FFFSC for different solar times are 1.87% and 71.61%, respectively. The mean value and maximum value of the local concentration ratio of the solar flux on the receiver are more than 86.64 and 1319.43, respectively. When the tracking error and periodical adjustment error are within 1 degrees, the eta(opt) of the FFFSC can reach 70.38% and 68.94%, respectively. The optical characteristics of FFFSC is also verified numerically. Especially, according to the total year simulation of the FFFSC's optical characteristics, maximum value of eta(re-opt),(loss) is 0.116%, which means the proposed the FFFSC can achieve fixed-focus.
引用
收藏
页数:16
相关论文
共 34 条
  • [1] Effects of receiver parameters on the optical performance of a fixed-focus Fresnel lens solar concentrator/cavity receiver system in solar cooker
    Wang, Hai
    Huang, Jin
    Song, Mengjie
    Yan, Jian
    APPLIED ENERGY, 2019, 237 : 70 - 82
  • [2] Comparative Study of a Fixed-Focus Fresnel Lens Solar Concentrator/Conical Cavity Receiver System with and without Glass Cover Installed in a Solar Cooker
    Wang, Hai
    SUSTAINABILITY, 2023, 15 (12)
  • [3] Design and optical analysis of the band-focus Fresnel lens solar concentrator
    Wang, Gang
    Chen, Zeshao
    Hu, Peng
    Cheng, Xiaofang
    APPLIED THERMAL ENGINEERING, 2016, 102 : 695 - 700
  • [4] Effects of Receiver Parameters on Solar Flux Distribution for Triangle Cavity Receiver in the Fixed Linear-Focus Fresnel Lens Solar Concentrator
    Wang, Hai
    Hu, Yanxin
    Peng, Jinqing
    Song, Mengjie
    Li, Haoteng
    SUSTAINABILITY, 2021, 13 (11)
  • [5] Analysis on influence characteristics of key parameters of small-scale fixed-focus linear Fresnel lens concentrator
    Li H.
    Huang J.
    Wang H.
    Yan J.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (05): : 230 - 237
  • [6] Optical and thermal performance of a uniaxial bidirectional tracked linear-focusing Fresnel lens solar concentrator
    Liang, Shen
    He, Qian
    Zheng, Hongfei
    Zhao, Zhiyong
    Kang, Huifang
    Ma, Xinglong
    Wang, Ge
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2022, 46 (13) : 18768 - 18780
  • [7] Optical performance of an azimuth tracking linear Fresnel solar concentrator
    Huang, Farong
    Li, Longlong
    Huang, Weidong
    SOLAR ENERGY, 2014, 108 : 1 - 12
  • [8] Study on design and performance enhancement of Fresnel lens solar concentrator
    Bachhav, Chetan Y.
    Sonawwanay, Puskaraj D.
    MATERIALS TODAY-PROCEEDINGS, 2022, 56 : 2873 - 2879
  • [9] Effects of receiver parameters on the optical efficiency of a fixed linear-focus Fresnel lens solar system with sliding adjustment
    Li, Haoteng
    Huang, Jin
    Wang, Hai
    Song, Mengjie
    ENERGY REPORTS, 2021, 7 : 3348 - 3361
  • [10] Experimental and optical performances of a solar CPV device using a linear Fresnel reflector concentrator
    Wang, Gang
    Wang, Fasi
    Shen, Fan
    Jiang, Tieliu
    Chen, Zeshao
    Hu, Peng
    RENEWABLE ENERGY, 2020, 146 (146) : 2351 - 2361