Automation of the ELISpot assay for high-throughput detection of antigen-specific T-cell responses

被引:15
作者
Almeida, Coral-Ann M. [1 ,2 ]
Roberts, Steven G. [1 ,2 ]
Laird, Rebecca [1 ,2 ]
McKinnon, Elizabeth [1 ,2 ]
Ahmed, Imran [1 ,2 ]
Pfafferott, Katja [1 ,2 ]
Turley, Joanne [1 ,2 ]
Keane, Niamh M. [1 ,2 ]
Lucas, Andrew [1 ,2 ]
Rushton, Ben [1 ,2 ]
Chopra, Abha [1 ,2 ]
Mallal, Simon [1 ,2 ,3 ]
John, Mina [1 ,2 ,3 ]
机构
[1] Royal Perth Hosp, Ctr Clin Immunol & Biomed Stat, Perth, WA 6000, Australia
[2] Murdoch Univ, Perth, WA, Australia
[3] Royal Perth Hosp, Dept Clin Immunol & Immunogenet, Perth, WA 6000, Australia
基金
英国医学研究理事会;
关键词
ELISpot; CD8(+) T-cells; IFN-gamma; Automation; High-throughput; HIV; CYTOKINE FLOW-CYTOMETRY; INFECTION; VIRUS; VALIDATION;
D O I
10.1016/j.jim.2009.02.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The enzyme linked immunospot (ELISpot) assay is a fundamental tool in cellular immunology, providing both quantitative and qualitative information on cellular cytokine responses to defined antigens. It enables the comprehensive screening of patient derived peripheral blood mononuclear cells to reveal the antigenic restriction of T-cell responses and is an emerging technique in clinical laboratory investigation of certain infectious diseases. As with all cellular-based assays, the final results of the assay are dependent on a number of technical variables that may impact precision if not highly standardised between operators. When studies that are large scale or using multiple antigens are set up manually, these assays may be labour intensive, have many manual handling steps, are subject to data and sample integrity failure and may show large inter-operator variability. Here we describe the successful automated performance of the interferon (IFN)-gamma ELISpot assay from cell counting through to electronic capture of cytokine quantitation and present the results of a comparison between automated and manual performance of the ELISpot assay. The mean number of spot forming units enumerated by both methods for limiting dilutions of CMV. EBV and influenza (CEF)-derived peptides in six healthy individuals were highly correlated (r>0.83, p<0.05). The precision results from the automated system compared favourably with the manual ELISpot and further ensured electronic tracking. increased through-put and reduced turnaround time. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [1] ELISPOT assay to measure antigen-specific murine CD8+ T cell responses
    Carvalho, LH
    Hafalla, JCR
    Zavala, F
    JOURNAL OF IMMUNOLOGICAL METHODS, 2001, 252 (1-2) : 207 - 218
  • [2] acDCs enhance human antigen-specific T-cell responses
    Martinuzzi, Emanuela
    Afonso, Georgia
    Gagnerault, Marie-Claude
    Naselli, Gaetano
    Mittag, Diana
    Combadiere, Behazine
    Boitard, Christian
    Chaput, Nathalie
    Zitvogel, Laurence
    Harrison, Leonard C.
    Mallone, Roberto
    BLOOD, 2011, 118 (08) : 2128 - 2137
  • [3] Evaluating antigen-specific cytotoxic T lymphocyte responses by a novel mouse granzyme B ELISPOT assay
    Ewen, CL
    Rong, IH
    Kokaji, AI
    Bleackley, RC
    Kane, KP
    JOURNAL OF IMMUNOLOGICAL METHODS, 2006, 308 (1-2) : 156 - 166
  • [4] A simple and efficient method for the monitoring of antigen-specific T cell responses using peptide pool arrays in a modified ELISpot assay
    Tobery, TW
    Wang, S
    Wang, XM
    Neeper, MP
    Jansen, KU
    McClements, WL
    Caulfield, MJ
    JOURNAL OF IMMUNOLOGICAL METHODS, 2001, 254 (1-2) : 59 - 66
  • [5] QUANTIFICATION OF ANTIGEN-SPECIFIC CD8(+) T-CELLS USING AN ELISPOT ASSAY
    MIYAHIRA, Y
    MURATA, K
    RODRIGUEZ, D
    RODRIGUEZ, JR
    ESTEBAN, M
    RODRIGUES, MM
    ZAVALA, F
    JOURNAL OF IMMUNOLOGICAL METHODS, 1995, 181 (01) : 45 - 54
  • [6] A valid ELISPOT assay for enumeration of ex vivo, antigen-specific, IFNγ-producing T cells
    Power, CA
    Grand, CL
    Ismail, N
    Peters, NC
    Yurkowski, DP
    Bretscher, PA
    JOURNAL OF IMMUNOLOGICAL METHODS, 1999, 227 (1-2) : 99 - 107
  • [7] Enumerating antigen-specific T-Cell responses in peripheral blood - A comparison of peptide MHC tetramer, ELISpot, and intracellular cytokine analysis
    Hobeika, AC
    Morse, MA
    Osada, T
    Ghanayem, M
    Niedzwiecki, D
    Barrier, R
    Lyerly, HK
    Clay, TM
    JOURNAL OF IMMUNOTHERAPY, 2005, 28 (01) : 63 - 72
  • [8] A high-throughput, bead-based, antigen-specific assay to assess the ability of antibodies to induce complement activation
    Fischinger, Stephanie
    Fallon, Jonathan K.
    Michell, Ashlin R.
    Broge, Thomas
    Suscovich, Todd J.
    Streeck, Hendrik
    Alter, Galit
    JOURNAL OF IMMUNOLOGICAL METHODS, 2019, 473
  • [9] Enhanced ELISPOT detection of antigen-specific T cell responses from cryopreserved specimens with addition of both IL-7 and IL-15 - the Amplispot assay
    Jennes, W
    Kestens, L
    Nixon, DF
    Shacklett, BL
    JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 270 (01) : 99 - 108
  • [10] Adaptive Nanoparticle Platforms for High Throughput Expansion and Detection of Antigen-Specific T cells
    Hickey, John W.
    Isser, Ariel
    Salathe, Sebastian F.
    Gee, Kayla M.
    Hsiao, Meng-Hsuan
    Shaikh, Wasamah
    Uzoukwu, Nkechi C.
    Bieler, Joan Glick
    Mao, Hai-Quan
    Schneck, Jonathan P.
    NANO LETTERS, 2020, 20 (09) : 6289 - 6298