Determination of 17β-estradiol and 17α-ethinylestradiol in water at sub-ppt levels by liquid chromatography coupled to tandem mass spectrometry

被引:28
|
作者
Ripolles, Cristina [1 ]
Ibanez, Maria [1 ]
Sancho, Juan V. [1 ]
Lopez, Francisco J. [1 ]
Hernandez, Felix [1 ]
机构
[1] Univ Jaume 1, Res Inst Pesticides & Water, E-12071 Castellon de La Plana, Spain
关键词
SOLID-PHASE EXTRACTION; ENDOCRINE-DISRUPTING COMPOUNDS; ATMOSPHERIC-PRESSURE PHOTOIONIZATION; WASTE-WATER; DRINKING-WATER; RIVER WATER; ESTROGENIC CHEMICALS; TREATMENT PLANTS; SURFACE-WATER; ELECTROSPRAY;
D O I
10.1039/c4ay00479e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Steroid estrogens are a group of endocrine disrupting compounds (EDCs) excreted in human urine mainly as glucuronide or sulfate conjugates, which might be converted back into the free estrogens in water. The natural estrogen 17 beta-estradiol (E2) and the synthetic one 17 alpha-ethinylestradiol (EE2) are of particular concern due to their strong estrogenic activity. The main environmental source of estrogen exposure is treated wastewaters, with the associated risk of releasing these pollutants to surface waters and even reaching finished drinking waters. In this work, we have developed and validated (at 0.1 and 1 ng L-1 levels) a robust and sensitive method based on Ultra-High Performance Liquid Chromatography (UHPLC) coupled to MS/MS for the reliable identification and quantification of E2 and EE2 in surface waters. Several sulfate conjugates have been also included into the methodology. A pre-concentration step based on off-line solid-phase extraction with Oasis HLB cartridges has been optimized prior to the UHPLC-(ESI) MS/MS determination with a last-generation triple quadrupole analyzer. Two isotopelabelled analytes (E2-d(4) and EE2-d(4)) have been used as surrogate standards to ensure an accurate quantification, achieving very low limits of detection for E2 (0.06 ng L-1) and EE2 (0.02 ng L-1). Several surface waters and influents and effluents from wastewater treatment plants have been analyzed to test the method applicability.
引用
收藏
页码:5028 / 5037
页数:10
相关论文
共 50 条
  • [31] Liquid chromatography-tandem mass spectrometry as a fast and simple method for the determination of several antibiotics in different aqueous matrices
    Voigt, Alexander M.
    Skutlarek, Dirk
    Timm, Christian
    Schreiber, Christiane
    Felder, Carsten
    Exner, Martin
    Faerber, Harald A.
    ENVIRONMENTAL CHEMISTRY, 2020, 17 (01) : 54 - 74
  • [32] Determination of cyclophosphamide and ifosfamide in sewage effluent by stable isotope-dilution liquid chromatography-tandem mass spectrometry
    Llewellyn, N.
    Lloyd, P.
    Juergens, M. D.
    Johnson, A. C.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (47) : 8519 - 8528
  • [33] Liquid chromatography tandem mass spectrometry determination of 34 priority and emerging pollutants in water from the influent and effluent of a drinking water treatment plant
    Borrull, Josep
    Colom, Agusti
    Fabregas, Josepa
    Borrull, Francesc
    Pocurull, Eva
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1621
  • [34] Microextraction Techniques Coupled to Liquid Chromatography with Mass Spectrometry for the Determination of Organic Micropollutants in Environmental Water Samples
    Torres Padron, Ma Esther
    Afonso-Olivares, Cristina
    Sosa-Ferrera, Zoraida
    Juan Santana-Rodriguez, Jose
    MOLECULES, 2014, 19 (07): : 10320 - 10349
  • [35] Analysis of anthelmintics in surface water by ultra high performance liquid chromatography coupled to quadrupole linear ion trap tandem mass spectrometry
    Zrncic, Mirta
    Gros, Meritxell
    Babic, Sandra
    Kastelan-Macan, Marija
    Barcelo, Damia
    Petrovic, Mira
    CHEMOSPHERE, 2014, 99 : 224 - 232
  • [36] Determination of estrogenic compounds in wastewater using liquid chromatography-tandem mass spectrometry with electrospray and atmospheric pressure photoionization following desalting extraction
    Chen, Hsin-Chang
    Kuo, Han-Wen
    Ding, Wang-Hsien
    CHEMOSPHERE, 2009, 74 (04) : 508 - 514
  • [37] Selective and trace determination of monochloramine in river water by chemical derivatization and liquid chromatography/tandem mass spectrometry analysis
    Kinani, Said
    Layousse, Stephany
    Richard, Bertille
    Kinani, Aziz
    Bouchonnet, Stephane
    Thoma, Astrid
    Sacher, Frank
    TALANTA, 2015, 140 : 189 - 197
  • [38] Determination of several pesticides in water by solid-phase extraction, liquid chromatography and electrospray tandem mass spectrometry
    Rodrigues, Alexandre Mourao
    Ferreira, Vera
    Cardoso, Vitor Vale
    Ferreira, Elisabete
    Benoliel, Maria Joao
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1150 (1-2) : 267 - 278
  • [39] Determination of four arsenic species in environmental water samples by liquid chromatography- inductively coupled plasma - tandem mass spectrometry
    Stetson, Sarah J.
    Lawrence, Caitlyn
    Whitcomb, Susan
    Kanagy, Christopher
    METHODSX, 2021, 8
  • [40] Rapid determination of free and conjugated estrogen in different water matrices by liquid chromatography-tandem mass spectrometry
    Kumar, Vimal
    Nakada, Norihide
    Yasojima, Makoto
    Yamashita, Naoyuki
    Johnson, Andrew C.
    Tanaka, Hiroaki
    CHEMOSPHERE, 2009, 77 (10) : 1440 - 1446