Feasibility study of total reflection X-ray fluorescence analysis using a liquid metal jet X-ray tube

被引:4
作者
Maderitsch, A. [1 ]
Smolek, S. [1 ]
Wobrauschek, P. [1 ]
Streli, C. [1 ]
Takman, P. [2 ]
机构
[1] Vienna Univ Technol, Atominstitut, A-1020 Vienna, Austria
[2] Excillum AB, S-16474 Kista, Sweden
关键词
Total reflection X-ray fluorescence; TXRF; Liquid metal jet; X-ray source; EXCITATION;
D O I
10.1016/j.sab.2014.06.003
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Total reflection X-ray spectroscopy (TXRF) is a powerful analytical technique for qualitative and quantitative analysis of trace and ultratrace elements in a sample with lower limits of detection (LLDs) of pg/g to ng/g in concentration and absolute high fg levels are attainable. Several X-ray sources, from low power (few W), 18 kW rotating anodes to synchrotron radiation, are in use for the excitation and lead accordingly to their photon flux delivered on the sample the detection limits specified. Not only the power, but also the brilliance and focal shape are of importance for TXRF. A microfocus of 50-100 gm spot size or the line focus of diffraction tubes is best suited. Excillum developed a new approach in the design of a source: the liquid metal jet anode. In this paper the results achieved with this source are described. A versatile TXRF spectrometer with vacuum chamber designed at Atominstitut was used for the experiments. A multilayer monochromator selecting the intensive Ga-K alpha radiation was taken and the beam was collimated by 50 pm slits. Excellent results regarding geometric beam stability, high fluorescence intensities and low background were achieved leading to detection limits in the high fg range for Ni. A 100 mm(2) silicon drift detector (SDD) collimated to 80 mm2 was used to collect the fluorescence radiation. The results from measurements on single element samples are presented. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:67 / 69
页数:3
相关论文
共 50 条
  • [41] Considerations on the ideal sample shape for Total Reflection X-ray Fluorescence Analysis
    Horntrich, C.
    Kregsamer, P.
    Wobrauschek, P.
    Streli, C.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (11-12) : 815 - 821
  • [42] Limits of detection of a total reflection X-ray fluorescence system with double reflection module
    Nascimento, VF
    Poblete, VH
    Parreira, PS
    Matsumoto, E
    Simabuco, SM
    Espinoza, EP
    Navarro, AA
    BIOLOGICAL TRACE ELEMENT RESEARCH, 1999, 71-2 (1) : 423 - 430
  • [43] Low Z total reflection X-ray fluorescence analysis - challenges and answers
    Streli, C
    Kregsamer, P
    Wobrauschek, P
    Gatterbauer, H
    Pianetta, P
    Pahlke, S
    Fabry, L
    Palmetshofer, L
    Schmeling, M
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (10) : 1433 - 1441
  • [44] Total reflection X-ray fluorescence analysis of uranium in the presence of competing elements
    Izumoto, Yukie
    Takamura, Kodai
    Matsuyama, Tsugufumi
    Nagai, Hiroki
    Sakai, Yasuhiro
    Oguri, Yoshiyuki
    Yoshii, Hiroshi
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 173
  • [45] Total Reflection X-ray Fluorescence attachment module modified for analysis in vacuum
    Wobrauschek, P.
    Streli, C.
    Kregsamer, P.
    Meirer, F.
    Jokubonis, C.
    Markowicz, A.
    Wegrzynek, D.
    Chinea-Cano, E.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (12) : 1404 - 1407
  • [46] Separation of Arsenic and Lead by Electrolysis for Total Reflection X-Ray Fluorescence Analysis
    Kunimura, Shinsuke
    Nagashima, Yoichi
    Mezaki, Yuya
    Yokoyama, Tatsuya
    ISIJ INTERNATIONAL, 2016, 56 (11) : 2110 - 2112
  • [47] Production of the ideal sample shape for Total Reflection X-ray Fluorescence analysis
    Horntrich, C.
    Kregsamer, P.
    Prost, J.
    Stadlbauer, F.
    Wobrauschek, P.
    Streli, C.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 77 : 31 - 34
  • [48] Total reflection X-ray fluorescence analysis of pollen as an indicator for atmospheric pollution
    Pepponi, G
    Lazzeri, P
    Coghe, N
    Bersani, M
    Gottardini, E
    Cristofolini, F
    Clauser, G
    Torboli, A
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (08) : 1205 - 1209
  • [49] Synchrotron radiation-induced total reflection X-ray fluorescence analysis
    Meirer, F.
    Singh, A.
    Pepponi, G.
    Streli, C.
    Homma, T.
    Pianetta, P.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2010, 29 (06) : 479 - 496
  • [50] Limits of detection of a total reflection x-ray fluorescence system with double reflection module
    V. F. Nascimento Filho
    V. H. Poblete
    P. S. Parreira
    E. Matsumoto
    S. M. Simabuco
    E. P. Espinoza
    A. A. Navarro
    Biological Trace Element Research, 1999, 71-72 : 423 - 430