Biomechanical analysis of fracture risk associated with tibia deformity in children with osteogenesis imperfecta: a finite element analysis

被引:0
作者
Caouette, C. [1 ,2 ]
Rauch, F. [2 ,3 ,4 ]
Villemure, I. [1 ,2 ]
Arnoux, P-J. [5 ,6 ]
Gdalevitch, M. [3 ,4 ]
Veilleux, L-N. [3 ,4 ]
Heng, J. L. [1 ]
Aubin, C-E. [1 ,2 ]
机构
[1] Polytech Montreal, Dept Mech Engn, Montreal, PQ H3C 3A7, Canada
[2] St Justine Univ, Ctr Hosp, Res Ctr, Montreal, PQ, Canada
[3] Shriners Hosp Children, Montreal, PQ, Canada
[4] McGill Univ, Montreal, PQ, Canada
[5] Univ Aix Marseille, Marseille, France
[6] IFSTTAR, Marseille, France
关键词
Osteogenesis Imperfecta; Finite Element; Tibia Deformity; Tibia Nailing Surgery; LONG BONES; MECHANICAL-PROPERTIES; PROXIMAL TIBIA; CORTICAL BONE; IN-VITRO; NANOINDENTATION; MODELS; STRENGTH; BEHAVIOR; FAILURE;
D O I
暂无
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Objectives: Osteogenesis imperfecta (OI) frequently leads to long-bone bowing requiring a surgical intervention in severe cases to avoid subsequent fractures. However, there are no objective criteria to decide when to perform such intervention. The objective is to develop a finite element model to predict the risk of tibial fracture associated with tibia deformity in patients with OI. Methods: A comprehensive FE model of the tibia was adapted to match bi-planar radiographs of a 7 year-old girl with OI. Ten additional models with different deformed geometries (from 2 degrees to 24 degrees) were created and the elasto-plastic mechanical properties were adapted to reflect OI conditions. Loads were obtained from mechanography of two-legged hopping. Two additional impact cases (lateral and torsion) were also simulated. Principal strain levels were used to define a risk criterion. Results: Fracture risks for the two-legged hopping load case remained low and constant until tibia bowing reached 15 degrees and 16 degrees in sagittal and coronal planes respectively. Fracture risks for lateral and torsion impact were equivalent whatever the level of tibial bowing. Conclusions: The finite element model of OI tibia provides an objective means of assessing the necessity of surgical intervention for a given level of tibia bowing in OI-affected children.
引用
收藏
页码:205 / 212
页数:8
相关论文
共 50 条
  • [41] Finite element analysis and clinical evaluation of cross locking external fixator configuration for distal third tibia fracture
    Bing Wui Ng
    Abdul Hadi Abdul Wahab
    Abdul Muttalib Abdul Wahid
    Nik Nur Ain Azrin Abdullah
    Mohammed Rafiq Abdul Kadir
    Muhammad Imam Ammarullah
    Muhammad Hanif Ramlee
    Scientific Reports, 15 (1)
  • [42] A comparative biomechanical analysis of suprapectineal and infrapectineal fixation on acetabular anterior column fracture by finite element modeling
    Yucens, Mehmet
    Alemdaroglu, Kadir Bahadir
    Ozmeric, Ahmet
    Iltar, Serkan
    Yildirim, Ahmet Ozgur
    Aydogan, Nevres H.
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2019, 49 (01) : 442 - 448
  • [43] Finite element analysis and computed tomography based structural rigidity analysis of rat tibia with simulated lytic defects
    Rennick, John A.
    Nazarian, Ara
    Entezari, Vahid
    Kimbaris, James
    Tseng, Alan
    Masoudi, Aidin
    Nayeb-Hashemi, Hamid
    Vaziri, Ashkan
    Snyder, Brian D.
    JOURNAL OF BIOMECHANICS, 2013, 46 (15) : 2701 - 2709
  • [44] Biomechanical Analysis of Orthodontic Correction of Buccally Malposed Canine: A Finite Element Analysis
    Ali, Muthanna Ibraheem
    Al Sheakli, Iman I.
    Al Zaidee, Salah R.
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (02): : 43 - 51
  • [45] Machine learning based finite element analysis (FEA) surrogate for hip fracture risk assessment and visualization
    Awal, Rabina
    Naznin, Mahmuda
    Faisal, Tanvir R.
    EXPERT SYSTEMS WITH APPLICATIONS, 2025, 264
  • [46] Biomechanical Analysis of Porous Additive Manufactured Cages for Lateral Lumbar Interbody Fusion: A Finite Element Analysis
    Zhang, Zhenjun
    Li, Hui
    Fogel, Guy R.
    Liao, Zhenhua
    Li, Yang
    Liu, Weiqiang
    WORLD NEUROSURGERY, 2018, 111 : E581 - E591
  • [47] Dual mobility cups provide biomechanical advantages in situations at risk for dislocation: a finite element analysis
    Terrier, Alexandre
    Latypova, Adeliya
    Guillemin, Maika
    Parvex, Valerie
    Guyen, Olivier
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (03) : 551 - 556
  • [48] Finite element analysis on the biomechanical stability of open porous titanium scaffolds for large segmental bone defects under physiological load conditions
    Wieding, Jan
    Souffrant, Robert
    Mittelmeier, Wolfram
    Bader, Rainer
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (04) : 422 - 432
  • [49] The role of the depth of resection of the distal tibia on biomechanical performance of the tibial component for TAR: A finite element analysis with three implant designs
    Jyoti
    Ghosh, Rajesh
    MEDICAL ENGINEERING & PHYSICS, 2023, 119
  • [50] Stress Distribution in Human Tibia Bones using Finite Element Analysis
    Tarapoom, Wanchalerm
    Puttapitukporn, Tumrong
    ENGINEERING JOURNAL-THAILAND, 2016, 20 (03): : 155 - 167