Experimental Study With Analytical Validation of Thermally Driven Flow in Risers of Solar Water Heaters Under Varying Scale Thickness and Heat Flux

被引:2
作者
Arunachala, U. C. [1 ]
Bhatt, M. Siddhartha [2 ]
Sreepathi, L. K. [3 ]
机构
[1] Manipal Inst Technol, Dept Mech & Mfg Engn, Manipal 576104, Karnataka, India
[2] Cent Power Res Inst, Energy Efficiency & Renewable Energy Div, Bangalore 560080, Karnataka, India
[3] JNN Coll Engn, Dept Mech Engn, Shimoga 577204, India
来源
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME | 2014年 / 136卷 / 02期
关键词
thermosiphon flat plate solar water heaters; flow simulation; risers; varying scale thicknesses; varying heat inputs; H-W-B constants; POLYPROPYLENE; SIMULATION; ABSORBER;
D O I
10.1115/1.4025716
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper investigates the deterioration in the performance of thermosiphon flat plate solar water heaters (SWH) with water side scaling. The study presents the analytical and experimental variation of mass flow rate of water with scale thickness in risers of conventional solar flat plate water heater for different electrical power inputs (covering the full range of solar incident radiation up to 1 kW/m(2)). This information is extended further to determine the drop in efficiency characteristics represented by the Hottel-Whillier-Bliss (H-W-B) constants for full-fledged SWH. To simulate scaling in risers in the absorber plate of a SWH, an artificial method of coating has been used to create single pipe riser of different uniform scale thicknesses. Four such risers are created with scale thickness of 0 mm, 0.7 mm, 1.7 mm, 2.7 mm, and 3.7 mm. The observed drop in mass flow rate through the range of risers between 0 mm and 3.7 mm scale thickness is 58.5% for the thermal input power (supplied through electric heating) of 129.5 W (corresponding to a solar incident radiation of 980 W/m(2)). In comparison, the analytical results show a corresponding drop of 70.12%. A comparison of the coated riser with a cut tube of an actually scaled riser indicates excellent matching of thermal conductivity. The divergence between experimental and analytical mass flow rate in the case of a riser of the highest scale thickness, viz., 3.7 mm, is the lowest because of increased pressure gain in the flow region together with higher temperature than predicted by the general equation. The experimental data of various energy parameters from the single tube scaled riser studies are matching with analytical values for the different input electrical power levels (corresponding to the different solar radiation levels). As identical conditions are used in the experimental analysis, the results for risers of various scale thicknesses and electrical power inputs are applicable to corresponding full-fledged SWH.
引用
收藏
页数:9
相关论文
共 21 条
  • [1] [Anonymous], MINISTRY NEW RENEWAB, P49
  • [2] Scaling Effect of Direct Solar Hot Water Systems on Energy Efficiency
    Arunachala, U. C.
    Bhatt, M. Siddhartha
    Sreepathi, L. K.
    [J]. JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (04):
  • [3] Designing solar hot water systems for scaling environments
    Baker, D
    Vliet, G
    [J]. JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (01): : 43 - 47
  • [4] Boehm Robert F., 1987, DESIGN ANAL THERMAL
  • [5] Duffie J.A., 1991, Solar Engineering of Thermal Processes, Vsecond
  • [6] Simulation of the opti-physical parameters of selectives surfaces of absorber by the FDTD method. "applied to solar water heater"
    Haddad, F.
    Chikouche, A.
    Laour, M.
    [J]. IMPACT OF INTEGRATED CLEAN ENERGY ON THE FUTURE OF THE MEDITERRANEAN ENVIRONMENT, 2011, 6 : 413 - 421
  • [7] Ilhan C., 2012, ENERGY BUILD, V47, P630
  • [8] A storage domestic solar hot water system with a back layer of phase change material
    Khalifa, Abdul Jabbar N.
    Suffer, Kadhim H.
    Mahmoud, Mahmoud Sh.
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 44 : 174 - 181
  • [9] CALCULATION OF FLAT-PLATE COLLECTOR LOSS COEFFICIENTS
    KLEIN, SA
    [J]. SOLAR ENERGY, 1975, 17 (01) : 79 - 80
  • [10] Kothandaraman C. P., 2006, HEAT MASS TRANSFER D