A ratiometric fluorescence platform based on boric-acid-functional Eu-MOF for sensitive detection of H2O2 and glucose

被引:234
|
作者
Cui, Yu [1 ,2 ]
Chen, Fei [1 ,2 ]
Yin, Xue-Bo [1 ,2 ,3 ]
机构
[1] Nankai Univ, Coll Chem, State Key Lab Med Chem Biol, Tianjin 300071, Peoples R China
[2] Nankai Univ, Coll Chem, Tianjin Key Lab Biosensing & Mol Recognit, Tianjin 300071, Peoples R China
[3] Nankai Univ, Collaborat Innovat Ctr Chem Sci & Engn Tianjin, Tianjin 300071, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Ratiometric detection; Boric acid group; Eu-MOF; H2O2; Glucose; METAL-ORGANIC FRAMEWORKS; HYDROGEN-PEROXIDE; ELECTRON-TRANSFER; CHEMISTRY; EMISSION; SENSOR; PROBE; HYBRID; ANIONS; FE3+;
D O I
10.1016/j.bios.2019.04.008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A Eu-metal organic framework (Eu-MOF) probe with dual-emission was reported for the ratiometric fluorescence detection of H2O2 and glucose. Because of the special nucleophilic reaction between boric group and H2O2, Eu3+ and 5-boronobenzene-1,3-dicarboxylic acid (BBDC) were selected to synthesize the functional MOF probe via a simple one-pot solvothermal method. The Eu-MOF shows dual-emission at 370 and 623 nm with the single excitation at 270 nm due to the energy transfer efficiency change for antenna effect procedure. After addition of H2O2, the red emission of Eu-MOF weakened and the blue emission enhances immediately under 270 nm irradiation, so the ratiometric fluorescence detection is established. Moreover, the obvious color change for visual measuring of H2O2 and glucose is illustrated to reveal the merit of Eu-MOF probe. The proposed method was demonstrated to be highly sensitive and selective for H2O2 and glucose, with the low detection limits of 0.0335 and 0.0643 mu M, respectively. The established boric-acid-functional Eu-MOF sensing platform was proved as the powerful probe for H2O2 and the metabolites involved in H2O2-generating reaction.
引用
收藏
页码:208 / 215
页数:8
相关论文
共 50 条
  • [21] Luminescent MOF nanosheets for enzyme assisted detection of H2O2 and glucose and activity assay of glucose oxidase
    Ning, Di
    Liu, Qiao
    Wang, Qian
    Du, Xiao-Meng
    Ruan, Wen-Juan
    Li, Yue
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 282 : 443 - 448
  • [22] Optimizing Colorimetric Assay Based on V2O5 Nanozymes for Sensitive Detection of H2O2 and Glucose
    Sun, Jiaheng
    Li, Chunyan
    Qi, Yanfei
    Guo, Shuanli
    Liang, Xue
    SENSORS, 2016, 16 (04):
  • [23] Trimetallic PdCuAu Nanoparticles for Temperature Sensing and Fluorescence Detection of H2O2 and Glucose
    Nie, Furong
    Ga, Lu
    Ai, Jun
    Wang, Yong
    FRONTIERS IN CHEMISTRY, 2020, 8
  • [24] A robust cluster-based Eu-MOF as multi-functional fluorescence sensor for detection of antibiotics and pesticides in water
    Wang, Gang-Ding
    Li, Yong-Zhi
    Shi, Wen-Juan
    Zhang, Bin
    Hou, Lei
    Wang, Yao-Yu
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 331
  • [25] Glucose oxidase conjugated H2O2 sensitive CdTe QDs: an effective fluorescence tool for glucose sensing
    Singh, Pooja
    Prabhune, Asmita A.
    Ogale, Satishchandra B.
    Guin, Debanjan
    JOURNAL OF MATERIALS CHEMISTRY B, 2013, 1 (47) : 6538 - 6543
  • [26] Sensitive fluorescent detection of H2O2 and glucose in human serum based on inner filter effect of squaric acid-iron(III) on the fluorescence of upconversion nanoparticle
    Chen, Hongyu
    Fang, Aijin
    He, Li
    Zhang, Youyu
    Yao, Shouzhuo
    TALANTA, 2017, 164 : 580 - 587
  • [27] Highly sensitive ratiometric fluorescence detection of tetracycline residues in food samples based on Eu/Zr-MOF
    Zhang, Lei
    He, Yuxin
    Wu, Yue
    Zhang, Jieyuan
    Li, Siqiao
    Zhang, Zhengwei
    FOOD CHEMISTRY, 2024, 436
  • [28] Facile and sensitive chemiluminescence detection of H2O2 and glucose by a gravity/capillary flow and cloth-based low-cost platform
    Li, Huijie
    Wang, Dan
    Liu, Cuiling
    Liu, Rui
    Zhang, Chunsun
    RSC ADVANCES, 2017, 7 (68): : 43245 - 43254
  • [29] Detection of H2O2 by Fluorescence Correlation Spectroscopy
    Ito, Etsuro
    Watabe, Satoshi
    Morikawa, Mika
    Kodama, Hiromi
    Okada, Ryuichi
    Miura, Toshiaki
    HYDROGEN PEROXIDE AND CELL SIGNALING, PT A, 2013, 526 : 135 - 143
  • [30] MnO2-Nanosheet-Modified Upconversion Nanosystem for Sensitive Turn-On Fluorescence Detection of H2O2 and Glucose in Blood
    Yuan, Jing
    Cen, Yao
    Kong, Xiang-Juan
    Wu, Shuang
    Liu, Chen-Liwei
    Yu, Ru-Qin
    Chu, Xia
    ACS APPLIED MATERIALS & INTERFACES, 2015, 7 (19) : 10548 - 10555