Stent-Assisted Coiling Versus Balloon Remodeling of Wide-Neck Aneurysms: Comparison of Angiographic Outcomes

被引:101
作者
Chalouhi, N. [1 ]
Starke, R. M. [1 ,2 ]
Koltz, M. T. [1 ]
Jabbour, P. M. [1 ]
Tjoumakaris, S. I. [1 ]
Dumont, A. S. [1 ]
Rosenwasser, R. H. [1 ]
Singhal, S. [1 ]
Gonzalez, L. F. [1 ]
机构
[1] Thomas Jefferson Univ, Dept Neurol Surg, Philadelphia, PA 19107 USA
[2] Univ Virginia, Dept Neurol Surg, Charlottesville, VA USA
关键词
RUPTURED INTRACRANIAL ANEURYSMS; ENDOVASCULAR TREATMENT; EMBOLIZATION DEVICE; DETACHABLE COILS; PACKING DENSITY; TRIAL ISAT; FOLLOW-UP; IN-VITRO; OCCLUSION; EXPERIENCE;
D O I
10.3174/ajnr.A3538
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Stent-assisted coiling and balloon-assisted coiling are 2 well-established techniques for treatment of wide-neck intracranial aneurysms. A direct comparative analysis of angiographic outcomes with the 2 techniques has not been available. We compare the angiographic outcomes of wide-neck aneurysms treated with stent-assisted coiling versus balloon-assisted coiling. MATERIALS AND METHODS: A retrospective review was conducted on 101 consecutive patients treated at our institution, 69 with stent-assisted coiling and 32 with balloon-assisted coiling. Two multivariate logistic regression analyses were performed to determine predictors of aneurysm obliteration and predictors of progressive aneurysm thrombosis at follow-up. RESULTS: The 2 groups were comparable with respect to all baseline characteristics with the exception of a higher proportion of ruptured aneurysms in the balloon-assisted coiling group (65.6%) than in the stent-assisted coiling group (11.5%, P < .001). Procedural complications did not differ between the stent-assisted coiling group (6%) and the balloon-assisted coiling group (9%, P = .5). The rates of complete aneurysm occlusion (Raymond score 1) at the most recent follow-up were significantly higher for the stent-assisted coiling group (75.4%) compared with the balloon-assisted coiling group (50%, P = .01). Progressive occlusion of incompletely coiled aneurysms was noted in 76.6% of aneurysms in the stent-assisted coiling group versus 42.8% in the balloon-assisted coiling group (P = .02). Retreatment rates were significantly lower with stent-assisted coiling (4.3%) versus balloon-assisted coiling (15.6%, P = .05). In multivariate analysis, stented aneurysms independently predicted both complete aneurysm obliteration and progression of occlusion. CONCLUSIONS: Stent-assisted coiling may yield lower rates of retreatment and higher rates of aneurysm obliteration and progression of occlusion at follow-up than balloon-assisted coiling with a similar morbidity rate.
引用
收藏
页码:1987 / 1992
页数:6
相关论文
共 25 条
  • [1] Altman DG., 1996, PRACTICAL STAT MED R, V7th
  • [2] Stent-Assisted Coiling of Wide-Necked Aneurysms in the Setting of Acute Subarachnoid Hemorrhage: Experience in 65 Patients
    Amenta, Peter S.
    Dalyai, Richard T.
    Kung, David
    Toporowski, Amy
    Chandela, Sid
    Hasan, David
    Gonzalez, L. Fernando
    Dumont, Aaron S.
    Tjoumakaris, Stavropoula I.
    Rosenwasser, Robert H.
    Maltenfort, Mitchell G.
    Jabbour, Pascal M.
    [J]. NEUROSURGERY, 2012, 70 (06) : 1415 - 1429
  • [3] The effect of vascular reconstruction device-assisted coiling on packing density, effective neck coverage, and angiographic outcome: An in vitro study
    Bendok, Bernard R.
    Parkinson, Richard J.
    Hage, Ziad A.
    Adel, Joseph G.
    Gounis, Matthew J.
    [J]. NEUROSURGERY, 2007, 61 (04) : 835 - 840
  • [4] Stent-Assisted Coiling in Acutely Ruptured intracranial Aneurysms: A Qualitative, Systematic Review of the Literature
    Bodily, K. D.
    Cloft, H. J.
    Lanzino, G.
    Fiorella, D. J.
    White, P. M.
    Kallmes, D. F.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (07) : 1232 - 1236
  • [5] Is Packing Density Important in Stent-Assisted Coiling?
    Chalouhi, Nohra
    Dumont, Aaron S.
    Hasan, David
    Tjoumakaris, Stavropoula
    Gonzalez, L. Fernando
    Starke, Robert M.
    Dalyai, Richard
    El Moursi, Sedeek
    Rosenwasser, Robert
    Jabbour, Pascal
    [J]. NEUROSURGERY, 2012, 71 (02) : 381 - 386
  • [6] Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils
    Cognard, C
    Weill, A
    Spelle, L
    Piotin, M
    Castaings, L
    Rey, A
    Moret, J
    [J]. RADIOLOGY, 1999, 212 (02) : 348 - 356
  • [7] Coiling of Intracranial Aneurysms A Systematic Review on Initial Occlusion and Reopening and Retreatment Rates
    Ferns, Sandra P.
    Sprengers, Marieke E. S.
    van Rooij, Willem Jan
    Rinkel, Gabriel J. E.
    van Rijn, Jeroen C.
    Bipat, Shandra
    Sluzewski, Menno
    Majoie, Charles B. L. M.
    [J]. STROKE, 2009, 40 (08) : E523 - E529
  • [8] Comparison of Devices Used for Stent-Assisted Coiling of Intracranial Aneurysms
    Izar, Benjamin
    Rai, Ansaar
    Raghuram, Karthikram
    Rotruck, Jill
    Carpenter, Jeffrey
    [J]. PLOS ONE, 2011, 6 (09):
  • [9] Stent-Associated Flow Remodeling Causes Further Occlusion of Incompletely Coiled Aneurysms
    Lawson, Matthew F.
    Newman, William C.
    Chi, Yueh-Yun
    Mocco, J. D.
    Hoh, Brian L.
    [J]. NEUROSURGERY, 2011, 69 (03) : 598 - 603
  • [10] Lodi Ym, 2011, J Vasc Interv Neurol, V4, P24