Effect of Heating and Cooling on Axially Restrained RC Columns with Special-Shaped Cross Section

被引:28
作者
Wu, Bo [1 ,2 ]
Li, Yi-Hai [1 ]
Chen, Shu-Liang [1 ]
机构
[1] S China Univ Technol, Dept Civil Engn, Guangzhou 510640, Peoples R China
[2] S China Univ Technol, State Key Lab Subtrop Bldg Sci, Guangzhou 510640, Peoples R China
基金
中国国家自然科学基金;
关键词
fire performance; RC column; special-shaped cross section; axial restraint; cooling phase; STEEL COLUMNS; FIRE RESISTANCE; STRUCTURAL CONTINUITY; CRITICAL-TEMPERATURE; THERMAL ELONGATION; CONCRETE COLUMNS; ASSEMBLIES; PERFORMANCE; RESPONSES; BEHAVIOR;
D O I
10.1007/s10694-009-0091-y
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper describes the performance of 12 axially restrained RC columns (four for each type of cross section, i.e., +-, T- and L-shaped cross section) under fire conditions that were recently finished in South China University of Technology. The main objective of the paper is to investigate the effect of axial restraint on RC columns during both expanding and contracting phases. The RC columns were all initially concentrically loaded and subjected to ISO834 standard fire on all sides. Axial restraints were imposed at the top of the columns to simulate the restraining effect of the rest of the whole frame. Different degrees of axial restraint were obtained by varying the length of the restraining beam. The boundary conditions of the columns were considered as fixed-fixed for all tests. It is found that restrained RC columns behave quite differently to isolated ones. No typical 'runaway' failure of isolated RC columns was observed in the fire test. Finally, the finite element software, SAFIR, is employed to conduct a numerical analysis of the tests.
引用
收藏
页码:231 / 249
页数:19
相关论文
共 27 条
[21]   Effects of structural continuity on fire resistant design of steel columns in non-sway multi-storey frames [J].
Wang, YC .
FIRE SAFETY JOURNAL, 1997, 28 (02) :101-116
[22]   An experimental study of the fire performance of non-sway loaded concrete-filled steel tubular column assemblies with extended end plate connections [J].
Wang, YC ;
Davies, JM .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2003, 59 (07) :819-838
[23]   Fire tests of non-sway loaded and rotationally restrained steel column assemblies [J].
Wang, YC ;
Davies, JM .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2003, 59 (03) :359-383
[24]   An experimental study of non-sway loaded and rotationally restrained steel column assemblies under fire conditions: analysis of test results and design calculations [J].
Wang, YC ;
Davies, JM .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2003, 59 (03) :291-313
[25]   The effects of structural continuity on the fire resistance of concrete filled columns in non-sway frames [J].
Wang, YC .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1999, 50 (02) :177-197
[26]   Behavior of axially-and-rotationally restrained concrete columns with ' plus '-shaped cross section and subjected to fire [J].
Wu, Bo ;
Xu, Yu-Ye .
FIRE SAFETY JOURNAL, 2009, 44 (02) :212-218
[27]  
[吴波 WU Bo], 2007, [建筑结构学报, Journal of Building Structures], V28, P24