Transient Characteristics of Split Air-Conditioning Systems Using R-22 and R-410A as Refrigerants

被引:30
|
作者
Kapadia, R. G. [1 ]
Jain, Sanjeev [2 ]
Agarwal, R. S. [2 ]
机构
[1] SVM Inst Technol, Dept Mech Engn, Bharuch, Gujarat, India
[2] Indian Inst Technol, Dept Mech Engn, New Delhi 110016, India
来源
HVAC&R RESEARCH | 2009年 / 15卷 / 03期
关键词
MOVING-BOUNDARY FORMULATION; ADIABATIC CAPILLARY TUBES; EVAPORATION HEAT-TRANSFER; DYNAMIC SIMULATION-MODEL; MICROFIN TUBES; PRESSURE-DROP; ALTERNATIVE REFRIGERANTS; NUMERICAL PREDICTION; THEORETICAL-ANALYSIS; 2-PHASE FLOWS;
D O I
10.1080/10789669.2009.10390854
中图分类号
O414.1 [热力学];
学科分类号
摘要
All air-conditioning systems experience transient processes during start-up and shutdown and varying boundary conditions during operation due to changes in space loads and outdoor air loads, control loop operation, etc. Transient characteristics of split air conditioners that use R-22 and R-410A as refrigerants are presented in this paper. The model used for the overall system simulation comprises compressor, capillary, condenser, and evaporator submodels. The condenser and evaporator are modelled using continuity, momentum, and energy equations over the space and time span, using the implicit finite difference approach. Both of the heat exchangers are assumed to be made tip of microfin tubes, although a comparison of transient pressure response with smooth tubes is presented in the paper. Appropriate correlations are used for calculating the two-phase heat transfer coefficients, the liquid vapor slip, and the friction factors. A simulation program is developed in the MATLAB (Mathworks 2004) environment linked with REFPROP. or refrigerant properties. The program is validated with measured and published experimental data. The transient simulation results including the pressure, the temperature, and the mass flow rate response for a start-lip transient are compared for R-22 and its alternative R-410A. The transient loss during start-up due to the reconditioning of thermal mass of the system and redistribution of the refrigerant among the system components is also compared for the two refrigerants.
引用
收藏
页码:617 / 649
页数:33
相关论文
共 15 条
  • [1] Condensation heat transfer characteristics of R-22, R-134a and R-410A in a single circular microtube
    Oh, Hoo-Kyu
    Son, Chang-Hyo
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2011, 35 (04) : 706 - 716
  • [2] Condensation heat transfer characteristics of R-22, R-134a and R-410A in small diameter tubes
    Son, Chang-Hyo
    Lee, Ho-Saeng
    HEAT AND MASS TRANSFER, 2009, 45 (09) : 1153 - 1166
  • [3] In-tube evaporation and condensation of R-22 and R-410A with plain and internally enhanced tubes
    Bogart, J
    Thors, P
    JOURNAL OF ENHANCED HEAT TRANSFER, 1999, 6 (01) : 37 - 50
  • [4] COMPARATIVE STUDY OF USING R-410A, R-407C, R-22 AND R-134A AS COOLING MEDIUM IN THE CONDENSER OF A STEAM POWER PLANT
    Yousef, Khaled
    Assefa, Abebayehu
    Hegazy, Ahmed
    Engeda, Abraham
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2014, VOL 5C, 2014,
  • [5] Comparative Study of Using R-410A, R-407C, R-22, and R-134a as Cooling Medium in the Condenser of a Steam Power Plant
    Yousef, Khaled
    Assefa, Abebayehu
    Hegazy, Ahmed
    Engeda, Abraham
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2015, 137 (02):
  • [6] An experimental study on convective boiling of R-22 and R-410A in horizontal smooth and micro-fin tubes
    Seo, K
    Kim, Y
    Lee, KJ
    Park, YC
    KSME INTERNATIONAL JOURNAL, 2001, 15 (08): : 1156 - 1164
  • [7] An experimental study on convective boiling of R-22 and R-410A in Horizontal smooth and micro-fin tubes
    Kookjeong Seo
    Yongchan Kim
    Kyu-Jung Lee
    Youn cheol Park
    KSME International Journal, 2001, 15 : 1156 - 1164
  • [8] The Effects of the Condenser Pressure Drop on the Cooling Performance of an Air Conditioning Unit using R-410A
    Stmardi, Cecep
    Markus
    Setyawan, Andriyanto
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON THERMOFLUIDS 2017 (THERMOFLUID 2017), 2018, 2001
  • [9] Retrofitting an air-conditioning device to utilize R1234yf and R1234ze(E) refrigerants as alternatives to R22
    Oruc, Vedat
    Devecioglu, Atilla G.
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2018, 40 (04)
  • [10] A cost-based method for comparing alternative refrigerants applied to R-22 systems
    Douglas, JD
    Braun, JE
    Groll, EA
    Tree, DR
    INTERNATIONAL JOURNAL OF REFRIGERATION, 1999, 22 (02) : 107 - 125