Risk assessment of predicted serum concentrations of bisphenol A in children and adults following treatment with dental composite restoratives, dental sealants, or orthodontic adhesives using physiologically based pharmacokinetic modeling

被引:5
作者
Bagley, Bradford D. [1 ]
Smith, Jordan N. [2 ,3 ]
Teeguarden, Justin G. [2 ,3 ]
机构
[1] 3M Corp Toxicol & Environm Sci, 3M Ctr, St Paul, MN 55144 USA
[2] Pacific Northwest Natl Lab, Exposure Sci, Richland, WA 99352 USA
[3] Oregon State Univ, Dept Environm & Mol Toxicol, Corvallis, OR 93771 USA
关键词
Bisphenol A (BPA); Bisphenol A glycidyl methacrylate (BisGMA); PBPK model; Dental; Orthodontic; Extract; Serum concentration;
D O I
10.1016/j.yrtph.2020.104839
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Bisphenol A (BPA) is a chemical used to manufacture bisphenol A glycidyl methacrylate (BisGMA). BisGMA has been used for decades in dental composite restoratives, sealants, and adhesives. Based on published studies, exposure to low concentrations of BPA are possible from dental and orthodontic devices. The serum BPA concentrations arising from such devices and oral doses were predicted using a PBPK model in children and adult females based on 1) published extraction data for cured and uncured 3M ESPE Filtek Supreme Ultra Flowable, 3M ESPE Filtek Bulk Fill Restorative, and 3M ESPE Clinpro Sealant and 2) published 20% ethanol/water and water rinsate data following orthodontic application with 3M ESPE Transbond MIP Primer and 3M ESPE Transbond XT Adhesive. Predicted oral exposure to BPA arising from these dental and orthodontic devices is low (median <10 ng/treatment) and predicted serum BPA concentrations were also low (<10(-4) nM). Even the maximum predicted exposure in this study (533.2 ng/treatment) yields a margin of exposure of 7.5 relative to the EFSA t-TDI (4 mu g/kg-day) and is only 2.8% of the daily BPA exposure for the US population in a 58-kg woman (15,660 ng/day). Therefore, the exposure to BPA arising from the 3M ESPE dental and orthodontic devices evaluated in this study is negligible relative to daily BPA exposure in the general population and these potential BPA sources do not constitute a risk to patients.
引用
收藏
页数:8
相关论文
共 54 条
[51]   Metabolism and kinetics of bisphenol A in humans at low doses following oral administration [J].
Vökel, W ;
Colnot, T ;
Csanády, GA ;
Filser, JG ;
Dekant, W .
CHEMICAL RESEARCH IN TOXICOLOGY, 2002, 15 (10) :1281-1287
[52]   Quantitation of bisphenol A and bisphenol A glucuronide in biological samples by high performance liquid chromatography-tandem mass spectrometry [J].
Volkel, W ;
Bittner, N ;
Dekant, W .
DRUG METABOLISM AND DISPOSITION, 2005, 33 (11) :1748-1757
[53]   Derivation of a bisphenol a oral reference dose (RfD) and drinking-water equivalent concentration [J].
Willhite, Calvin C. ;
Ball, Gwendolyn L. ;
McLellan, Clifton J. .
JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART B-CRITICAL REVIEWS, 2008, 11 (02) :69-146
[54]   Development of a physiologically based pharmacokinetic model for assessment of human exposure to bisphenol A [J].
Yang, Xiaoxia ;
Doerge, Daniel R. ;
Teeguarden, Justin G. ;
Fisher, Jeffrey W. .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 2015, 289 (03) :442-456