High throughput 96-well plate assay for receptor-mediated phosphatidylinositol turnover

被引:4
|
作者
Tian, Y [1 ]
Wu, LH [1 ]
Chung, FZ [1 ]
机构
[1] WARNER LAMBERT PARKE DAVIS,PARKE DAVIS PHARMACEUT RES,DEPT BIOL MOL,ANN ARBOR,MI 48105
关键词
D O I
10.1177/108705719700200207
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The G-protein coupled receptor family represents a large number of neurotransmitter receptors, Among the diverse signal transduction pathways mediated via G-proteins, phospholipase C mediated phosphatidylinositol hydrolysis represents one of the best characterized signal transduction mechanisms. Accordingly, the measurement of agonist-induced phosphatidylinositol turnover has been used as a convenient functional assay for receptor activation, Assays currently used for this purpose, however, are not suitable for high throughput screening, In this article, an improved technique using 96-well microtiter plate format for measuring phosphatidylinositol turnover is introduced, Anion exchange columns were prepared ion fiber glass 96-well multiscreen filter plate, Separation and detection of released inositol phosphates were conducted in a 96-well format, Cells expressing certain neurotransmitter receptors were challenged with agonists and the receptor-mediated PI turnover was measured by the new technique and the results obtained were compared to that obtained from traditional assays, The results indicate that the 96-well assay is 10 to 20 times more efficient than the traditional method and is, furthermore, suitable for high throughput drug screening, Our data also indicate that this method is particularly useful for characterizing multiple antagonists by Schild analysis.
引用
收藏
页码:91 / 97
页数:7
相关论文
共 50 条
  • [1] High-throughput insulin autoantibody assay: 96-well filtration plate format
    Yu, LP
    Robles, D
    Rewers, M
    Kaur, P
    Keleman, K
    Eisenbarth, GS
    DIABETES, 1999, 48 : A213 - A214
  • [2] A 96-well plate assay for high-throughput analysis of holocarboxylase synthetase activity
    Rios-Avila, Luisa
    Prince, Sara A.
    Wijeratne, Subhashinee S. K.
    Zempleni, Janos
    CLINICA CHIMICA ACTA, 2011, 412 (9-10) : 735 - 739
  • [3] High throughput Comet assay using 96-well plates
    Kiskinis, E
    Suter, W
    Hartmann, A
    MUTAGENESIS, 2002, 17 (01) : 37 - 43
  • [4] Automated high throughput single cell analysis in a 96-well plate
    Fishwild, DM
    Gillis, K
    Tran, K
    Fong, K
    Morris, G
    MOLECULAR BIOLOGY OF THE CELL, 2002, 13 : 552A - 552A
  • [5] High throughput adjustable 96-well plate assay for androgen receptor binding: A practical approach for EDC screening using the chimpanzee AR
    Hartig, P. C.
    Cardon, M. C.
    Blystone, C. R.
    Gray, L. E., Jr.
    Wilson, V. S.
    TOXICOLOGY LETTERS, 2008, 181 (02) : 126 - 131
  • [6] 96-well plate assay for sublethal metabolic activity
    Yang, YS
    Balcarcel, RR
    ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2004, 2 (04) : 353 - 361
  • [7] Evaluation of antibacterial activity of Australian basidiomycetous macrofungi using a high-throughput 96-well plate assay
    Bala, Neeraj
    Aitken, Elizabeth A. B.
    Fechner, Nigel
    Cusack, Andrew
    Steadman, Kathryn J.
    PHARMACEUTICAL BIOLOGY, 2011, 49 (05) : 492 - 500
  • [8] POTENCY ASSAYS FOR ANISTREPLASE - COMPARISON OF THE FIBRIN PLATE ASSAY AND A 96-WELL PLATE ASSAY
    BEEBE, DP
    GAFFNEY, PJ
    VANSCHIE, DMV
    BIOLOGICALS, 1992, 20 (02) : 129 - 133
  • [9] A SEMIAUTOMATED, 96-WELL PLATE ASSAY FOR COLLAGEN-SYNTHESIS
    SCUTT, A
    BERG, A
    MAYER, H
    ANALYTICAL BIOCHEMISTRY, 1992, 203 (02) : 290 - 294
  • [10] 96-Well Filtration Plate
    不详
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (19) : 3479 - 3480