Reliability of Optic Nerve Ultrasound for the Evaluation of Patients with Spontaneous Intracranial Hemorrhage

被引:185
作者
Moretti, Riccardo [1 ]
Pizzi, Barbara [1 ]
Cassini, Fabrizio [1 ]
Vivaldi, Nicoletta [1 ]
机构
[1] Osped SS Antonio & Biagio & Cesare Arrigo, Dept Anesthesia & Crit Care, I-15100 Alessandria, Italy
关键词
Optic nerve sheath diameter; Ultrasound; Intracranial hemorrhage; Intracranial pressure; TRANSORBITAL SONOGRAPHIC EVALUATION; SHEATH DIAMETER; PRESSURE; HYPERTENSION; ULTRASONOGRAPHY; FUNDAMENTALS; EXPANSION;
D O I
10.1007/s12028-009-9250-8
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The aim of our study is to confirm the reliability of optic nerve ultrasound as a method to detect intracranial hypertension in patients with spontaneous intracranial hemorrhage, to assess the reproducibility of the measurement of the optic nerve sheath diameter (ONSD), and to verify that ONSD changes concurrently with intracranial pressure (ICP) variations. Sixty-three adult patients with subarachnoid hemorrhage (n = 34) or primary intracerebral hemorrhage (n = 29) requiring sedation and invasive ICP monitoring were enrolled in a 10-bed multivalent ICU. ONSD was measured 3 mm behind the globe through a 7.5-MHz ultrasound probe. Mean binocular ONSD was used for statistical analysis. ICP values were registered simultaneously to ultrasonography. Twenty-eight ONSDs were measured consecutively by two different observers, and interobserver differences were calculated. Twelve coupled measurements were taken before and within 1 min after cerebrospinal fluid (CSF) drainage to control elevated ICP. Ninety-four ONSD measurements were analyzed. 5.2 mm proved to be the optimal ONSD cut-off point to predict raised ICP (> 20 mmHg) with 93.1% sensitivity (95% CI: 77.2-99%) and 73.85% specificity (95% CI: 61.5-84%). ONSD-ICP correlation coefficient was 0.7042 (95% CI for r = 0.5850-0.7936). The median interobserver ONSD difference was 0.25 mm. CSF drainage to control elevated ICP caused a rapid and significant reduction of ONSD (from 5.89 +/- A 0.61 to 5 +/- A 0.33 mm, P < 0.01). Our investigation confirms the reliability of optic nerve ultrasound as a non-invasive method to detect elevated ICP in intracranial hemorrhage patients. ONSD measurements proved to have a good reproducibility. ONSD changes almost concurrently with CSF pressure variations.
引用
收藏
页码:406 / 410
页数:5
相关论文
共 20 条
  • [1] Elevated intracranial pressure detected by bedside emergency ultrasonography of the optic nerve sheath
    Blaivas, M
    Theodoro, D
    Sierzenski, PR
    [J]. ACADEMIC EMERGENCY MEDICINE, 2003, 10 (04) : 376 - 381
  • [2] Optic nerve ultrasound: artifacts and real images
    Copetti, Roberto
    Cattarossi, Luigi
    [J]. INTENSIVE CARE MEDICINE, 2009, 35 (08) : 1488 - 1489
  • [3] Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients
    Geeraerts, Thomas
    Merceron, Sybille
    Benhamou, Dan
    Vigue, Bernard
    Duranteau, Jacques
    [J]. INTENSIVE CARE MEDICINE, 2008, 34 (11) : 2062 - 2067
  • [4] Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury
    Geeraerts, Thomas
    Launey, Yoann
    Martin, Laurent
    Pottecher, Julien
    Vigue, Bernard
    Duranteau, Jacques
    Benhamou, Dan
    [J]. INTENSIVE CARE MEDICINE, 2007, 33 (10) : 1704 - 1711
  • [5] Reply to Copetti and Cattarossi
    Geeraerts, Thomas
    Berges, Olivier
    Merceron, Sybille
    Launey, Yoann
    Benhamou, Dan
    Vigue, Bernard
    Duranteau, Jacques
    [J]. INTENSIVE CARE MEDICINE, 2009, 35 (08) : 1490 - 1491
  • [6] Use of T2-weighted magnetic resonance imaging of the optic nerve sheath to detect raised intracranial pressure
    Geeraerts, Thomas
    Newcombe, Virginia F. J.
    Coles, Jonathan P.
    Abate, Maria Giulia
    Perkes, Iain E.
    Hutchinson, Peter J. A.
    Outtrim, Jo G.
    Chatfield, Dot A.
    Menon, David K.
    [J]. CRITICAL CARE, 2008, 12 (05):
  • [7] Utility of optic nerve ultrasonography in head injury
    Goel, Ravishankar S.
    Goyal, Navin K.
    Dharap, Satish B.
    Kumar, Meena
    Gore, Madhuri A.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2008, 39 (05): : 519 - 524
  • [8] Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: Ultrasound findings during intrathecal infusion tests
    Hansen, HC
    Helmke, K
    [J]. JOURNAL OF NEUROSURGERY, 1997, 87 (01) : 34 - 40
  • [9] HAYREH S S, 1964, Br J Ophthalmol, V48, P522, DOI 10.1136/bjo.48.10.522
  • [10] Detection and monitoring of intracranial pressure dysregulation in liver failure by ultrasound
    Helmke, K
    Burdelski, M
    Hansen, HC
    [J]. TRANSPLANTATION, 2000, 70 (02) : 392 - 395