Chest-Worn Self-Injection-Locked Oscillator Tag for Monitoring Heart Rate Variability

被引:0
作者
El Arif, Rezki [1 ]
Su, Wei-Chih [1 ]
Tang, Mu-Cyun [1 ]
Horng, Tzyy-Sheng [1 ]
Wang, Fu-Kang [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Elect Engn, Kaohsiung, Taiwan
来源
PROCEEDINGS OF THE 2020 IEEE/MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS) | 2020年
关键词
Wearable sensor; heart rate variability; self-injection-locking; complementary slot ring resonator; RADAR;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a 5.8 GHz wireless chest-worn sensor for monitoring heart rate variability (HRV). The sensor consists of a self-injection-locked oscillator (SILO) and a tag antenna. It transmits a radio -frequency (RF) signal that is frequency-modulated based on self-injection-locking by the physiological motion of the chest to a handheld receiver for demodulation to analyze HRV. The tag antenna is a stacked structure composed of a complementary slot ring resonator (CSRR) and a circularly polarized (CP) slot radiator, playing important roles as a near-field sensing tip and a far-field radiation antenna. As an experimental result, the comparison of the inter-beat interval (IBI) data between the proposed sensor system and an electrocardiogram (ECG) equipment for a wearer shows excellent agreement.
引用
收藏
页码:512 / 515
页数:4
相关论文
共 15 条
  • [1] [Anonymous], 2012, Microwave Engineering
  • [2] Designing a Metasurface-based Tag Antenna for Wearable Vital Sign Sensors
    El Arif, Rezki
    Tang, Mu-Cyun
    Su, Wei-Chih
    Horng, Tzyy-Sheng
    Wang, Fu-Kang
    Tseng, Chao-Hsiung
    [J]. 2019 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS), 2019, : 373 - 376
  • [3] An Ultra-Broadband Direct Demodulator for Microwave FM Receivers
    Gheidi, Hamed
    Banai, Ali
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2011, 59 (08) : 2131 - 2139
  • [4] Horng TS, 2013, ASIA PACIF MICROWAVE, P566, DOI 10.1109/APMC.2013.6694866
  • [5] Hsu CY, 2018, IEEE MTT S INT MICR, P248, DOI 10.1109/MWSYM.2018.8439390
  • [6] Assessment of Heart Rate Variability and Respiratory Sinus Arrhythmia via Doppler Radar
    Massagram, Wansuree
    Lubecke, Victor M.
    Host-Madsen, Anders
    Boric-Lubecke, Olga
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2009, 57 (10) : 2542 - 2549
  • [7] High-Accuracy Heart Rate Variability Monitoring Using Doppler Radar Based on Gaussian Pulse Train Modeling and FTPR Algorithm
    Nosrati, Mehrdad
    Tavassolian, Negar
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2018, 66 (01) : 556 - 567
  • [8] Feature-Based Correlation and Topological Similarity for Interbeat Interval Estimation Using Ultrawideband Radar
    Sakamoto, Takuya
    Imasaka, Ryohei
    Taki, Hirofumi
    Sato, Toru
    Yoshioka, Mototaka
    Inoue, Kenichi
    Fukuda, Takeshi
    Sakai, Hiroyuki
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (04) : 747 - 757
  • [9] A Wearable Self-Injection-Locked Sensor With Active Integrated Antenna and Differentiator-Based Envelope Detector for Vital-Sign Detection From Chest Wall and Wrist
    Tseng, Chao-Hsiung
    Yu, Li-Te
    Huang, Jyun-Kai
    Chang, Chih-Lin
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2018, 66 (05) : 2511 - 2521
  • [10] Chest-Worn Health Monitor Based on a Bistatic Self-Injection-Locked Radar
    Wang, Fu-Kang
    Chou, You-Rung
    Chiu, Yen-Chen
    Horng, Tzyy-Sheng
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (12) : 2931 - 2940