Effects of surface EMG rectification on power and coherence analyses: An EEG and MEG study

被引:76
作者
Yao, Bing
Salenius, Stephen
Yue, Guang H.
Brown, Robert W.
Liu, Jing Z.
机构
[1] Cleveland Clin Fdn, Lerner Res Inst, Dept Biomed Engn, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Dept Phys Med & Rehabil, Cleveland, OH 44195 USA
[3] Case Western Reserve Univ, Dept Phys, Cleveland, OH 44106 USA
[4] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[5] Aalto Univ, Low Temp Lab, Brain Res Unit, FI-02150 Espoo, Finland
[6] Univ Helsinki, Dept Psychiat, FI-00014 Espoo, Finland
关键词
power spectrum; frequency; electromyography (EMG); electroencephalography (EEG); magnetoencephalography (MEG); CORTICOMUSCULAR COHERENCE; PHYSIOLOGICAL TREMOR; MOTOR CORTEX; HAND MUSCLE; AMPLITUDE; ELECTROMYOGRAMS; OSCILLATIONS; CONTRACTION;
D O I
10.1016/j.jneumeth.2006.07.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Coherence between electromyography (EMG) and electroencephalography (EEG) or magnetoencephalography (MEG) is frequently examined to gain insights on neuromuscular binding. Commonly, EMG signals are rectified before coherence is computed. However, the appropriateness of EMG rectification in computing EMG-EEG/MEG coherence has never been validated. Since rectification is a non-linear operation and alters the EMG power spectrum, such a validation is important to ensure the accuracy of coherence calculation. In this study we experimentally investigated the effects of EMG rectification on EMG power spectra and its coherence with EEG/MEG signals. Subjects performed sustained isometric index finger abduction at similar to 5-10% maximal voluntary force (in both EEG-EMG and MEG-EMG experiments) and index finger tapping at similar to 2-4Hz (in EEG-EMG experiment only). Bipolar surface EMG data from the first dorsal interosseus (FDI) and EEG/MEG signals from the contralateral primary sensorimotor area (C3) were recorded simultaneously. Power spectra and coherence with the EEGIMEG were calculated before and after EMG rectification. The results show that rectification shifts EMG power to lower frequencies, possibly enhancing peaks of motor unit firing. Coherences with the EEG/MEG signals were not significantly changed by EMG rectification, indicating EMG rectification is overall an appropriate procedure in power and coherence analyses. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:215 / 223
页数:9
相关论文
共 37 条
[1]   Cortical networks generating movement-related EEG rhythms in Alzheimer's disease: An EEG coherence study [J].
Babiloni, C ;
Miniussi, C ;
Moretti, DV ;
Vecchio, F ;
Salinari, S ;
Frisoni, G ;
Rossini, PM .
BEHAVIORAL NEUROSCIENCE, 2004, 118 (04) :698-706
[2]   NONLINEAR SUMMATION OF RESPONSES IN AVERAGES OF RECTIFIED EMG [J].
BAKER, SN ;
LEMON, RN .
JOURNAL OF NEUROSCIENCE METHODS, 1995, 59 (02) :175-181
[3]   Coherent oscillations in monkey motor cortex and hand muscle EMG show task-dependent modulation [J].
Baker, SN ;
Olivier, E ;
Lemon, RN .
JOURNAL OF PHYSIOLOGY-LONDON, 1997, 501 (01) :225-241
[4]   Coherent cortical and muscle discharge in cortical myoclonus [J].
Brown, P ;
Farmer, SF ;
Halliday, DM ;
Marsden, J ;
Rosenberg, JR .
BRAIN, 1999, 122 :461-472
[5]   Abnormal corticomuscular coherence is associated with the small amplitude cortical myoclonus in Parkinson's disease [J].
Caviness, JN ;
Adler, CH ;
Sabbagh, MN ;
Connor, DJ ;
Hernandez, JL ;
Lagerlund, TD .
MOVEMENT DISORDERS, 2003, 18 (10) :1157-1162
[6]   Sampling, noise-reduction and amplitude estimation issues in surface electromyography [J].
Clancy, EA ;
Morin, EL ;
Merletti, R .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2002, 12 (01) :1-16
[7]   Stretch reflex instability compared in three different human muscles [J].
Durbaba, R ;
Taylor, A ;
Manu, CA ;
Buonajuti, M .
EXPERIMENTAL BRAIN RESEARCH, 2005, 163 (03) :295-305
[8]  
Gradshteyn I. S., 2014, Tables of Integrals, Series, and Products, V8th
[9]   Cortico-muscular synchronization during isometric muscle contraction in humans as revealed by magnetoencephalography [J].
Gross, J ;
Tass, PA ;
Salenius, S ;
Hari, R ;
Freund, HJ ;
Schnitzler, A .
JOURNAL OF PHYSIOLOGY-LONDON, 2000, 527 (03) :623-631
[10]   EEG-EMG, MEG-EMG and EMG-EMG frequency analysis: physiological principles and clinical applications [J].
Grosse, P ;
Cassidy, MJ ;
Brown, P .
CLINICAL NEUROPHYSIOLOGY, 2002, 113 (10) :1523-1531