Finite element modelling of surface acoustic wave device based corrugated microdiaphragms

被引:4
作者
Dissanayake, Don W. [1 ,2 ]
Al-Sarawi, Said [1 ,2 ]
Lu, Tien-Fu [3 ]
Abbott, Derek [1 ,2 ,4 ]
机构
[1] Univ Adelaide, Ctr High Performance Integrated Technol & Syst CH, Adelaide, SA 5005, Australia
[2] Univ Adelaide, Sch Elect & Elect Engn, Adelaide, SA 5005, Australia
[3] Univ Adelaide, Sch Mech Engn, Adelaide, SA 5005, Australia
[4] Univ Adelaide, Ctr Biomed Engn CBME, Adelaide, SA 5005, Australia
基金
澳大利亚研究理事会;
关键词
MICROPUMP; PERFORMANCE; SIMULATION; DIAPHRAGM; DESIGN;
D O I
10.1088/0964-1726/18/9/095030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper presents modelling and analysis of microdiaphragms that are designed for implantable micropump applications. Microdiaphragms are considered to be a major component of micropumps. A securely operated, electrostatically actuated, fully passive micropump is designed using a novel method, which is based on surface acoustic wave (SAW) devices and wireless transcutaneous radio frequency (RF) communication. The device is capable of extracting the required power from the RF signal itself, like RFID (ID: identification device) tags; hence the need of a battery and active electronics is negated. Moreover, a SAW correlator is used for secure interrogation of the device. As a result, the device responds only to a unique RF signal, which has the same code as was implanted in the SAW correlator. Finite element analysis (FEA) based on code from ANSYS Inc. is carried out to model the microdiaphragm, and a Rayleigh-Ritz method based analytical model is developed to investigate the validity of the FEA results. During the FEA, a three-dimensional model of the diaphragm is developed and various kinds of corrugation profiles are considered for enhancing the device performance. A coupled-field analysis is carried out to model the electrostatics - solid interaction between the corrugated microdiaphragm and the SAW device. In modelling microdiaphragms, selection of appropriate material properties and element types, application of accurate constraints, and selection of suitable mesh parameters are carefully considered.
引用
收藏
页数:11
相关论文
共 34 条
[1]  
[Anonymous], SENS TRANSDUCERS J
[2]  
BAO MH, 2000, HDB SENSORS ACTUATOR, V8, P23
[3]   Simulation and optimization of a piezoelectric micropump for medical applications [J].
Cui, Qifeng ;
Liu, Chengliang ;
Zha, Xuan F. .
INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2008, 36 (5-6) :516-524
[4]  
Dissanayake D. W., 2007, 2 INT C SENS TECHN N, P381
[5]  
DISSANAYAKE DW, 2008, LECT NOTES ELECT ENG, V20, P139
[6]  
DISSANAYAKE DW, 2008, P SPIE, V6928
[7]  
FRANCAIS O, 2000, P MSM 2000 MARCH, P281
[8]   Analytical analysis and finite element simulation of advanced membranes for silicon microphones [J].
Füldner, M ;
Dehé, A ;
Lerch, R .
IEEE SENSORS JOURNAL, 2005, 5 (05) :857-863
[9]  
Gad-el-Hak M., 2002, APPL MECH REV
[10]  
GILBERT JR, 1996, MICR EL MECH SYST 19, P127