Nonlinearity Simulation of Digital SiPM Response for Inhomogeneous Light

被引:1
|
作者
Kumar, S. [1 ]
Herzkamp, M. [1 ]
van Waasen, S. [1 ,2 ]
机构
[1] Forschungszentrum Julich, Cent Inst Engn Elect & Analyt ZEA 2 Elect Syst, D-52425 Julich, Germany
[2] Univ Duisburg Essen, Fac Engn, Commun Syst NTS, D-47057 Duisburg, Germany
关键词
Photonics; Neutrons; Scintillators; Detectors; Optical saturation; Optical detectors; Glass; photodetectors; position-sensitive; particle detectors; radiation detectors; scintillators;
D O I
10.1109/TNS.2021.3049675
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Currently, we are developing a neutron scintillation detector prototype using silicon photomultipliers (SiPMs) as the photodetector. In order to reconstruct the position of single neutron events to an accuracy better than the pixel pitch of the SiPM, a very accurate photon count is required. Each pixel consists of 3200 microcells, operated in Geiger mode. A cell which is already triggered cannot detect any following photons hitting the cell, until it is recharged. This leads to a nonlinearity in the pixel's response for a higher photon density impinging across the pixel. Previous studies provided a correction factor to estimate the saturation, by assuming a homogeneous photon distribution density and comparing it to the number of microcells. In our specific application, the photon distribution is not homogeneous, which is why we examined the influence of the homogeneity on the saturation. In this work, we present a case study for difference in nonlinearity effect for an inhomogeneous and homogeneous photon distribution density, given the light intensity is equal. The simulation results suggest that the effect could be higher for an inhomogeneous distribution. Therefore, care must be taken when using the established correction factor for saturation and an analysis of the photon distribution homogeneity is necessary.
引用
收藏
页码:354 / 358
页数:5
相关论文
共 50 条
  • [1] Performance comparison between ceramic Ce:GAGG and single crystal Ce:GAGG with digital-SiPM
    Park, C.
    Kim, C.
    Kim, J.
    Lee, Y.
    Na, Y.
    Lee, K.
    Yeom, J. Y.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [2] A CMOS Digital SiPM With Focal-Plane Light-Spot Statistics for DOI Computation
    Vornicu, Ion
    Bandi, Franco N.
    Carmona-Galan, Ricardo
    Rodriguez-Vazquez, Angel
    IEEE SENSORS JOURNAL, 2017, 17 (03) : 632 - 643
  • [3] Validated simulation for LYSO:Ce scintillator based PET detector modules built on fully digital SiPM arrays
    Jatekos, B.
    Gasparini, L.
    Lorincz, E.
    Erdei, G.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [4] SiPM based photon counting detector for scanning digital radiography
    Babichev, E. A.
    Baru, S. E.
    Grigoriev, D. N.
    Oleynikov, V. P.
    Porosev, V. V.
    Savinov, G. A.
    Callier, Stephane
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [5] A GEANT4 Monte Carlo simulation to describe the time response of a coupled SiPM and LYSO detection system
    Leming, E.
    De Santo, A.
    Salvatore, F.
    Camanzi, B.
    Lohstroh, A.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [6] Optimizing the light output of a plastic scintillator and SiPM based detector through optical characterization and simulation: a case study for POLAR-2
    De Angelis, Nicolas
    Cadoux, Franck
    Husi, Coralie
    Kole, Merlin
    Mianowski, Slawomir
    JOURNAL OF INSTRUMENTATION, 2025, 20 (02):
  • [7] Digital Signal Processing for SiPM Timing Resolution
    Philippov, D. E.
    Popova, E. V.
    Belyaev, V. N.
    Buzhan, P. Z.
    Stifutkin, A. A.
    Vinogradov, S. L.
    INTERNATIONAL CONFERENCE ON PARTICLE PHYSICS AND ASTROPHYSICS, 2017, 798
  • [8] Light-Trap: A SiPM upgrade for very high energy astronomy and beyond
    Guberman, D.
    Cortina, J.
    Ward, J. E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 912 : 61 - 63
  • [9] Depth of Interaction Measurements Based on Rectangular Light Sharing Window Technology and Nine-Crystals-to-One-SiPM Coupling Method
    Zhang, Xi
    Ye, Baihezi
    Yu, Hongsen
    Zhang, Yuyu
    Xie, Siwei
    Xu, Jianfeng
    Peng, Qiyu
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (03) : 306 - 314
  • [10] Study of timing performance parameters for a SiPM-based digital positron annihilation lifetime spectrometer
    Choi, H.
    Ko, K.
    Kim, W.
    Lee, J.
    Sun, G.
    Chang, H.
    Yi, Y.
    Cho, G.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (12):