Comparison of clinical efficacy and complications between Q-switched alexandrite laser and Q-switched Nd:YAG laser on nevus of Ota: a systematic review and meta-analysis

被引:16
作者
Yu, Panxi [1 ,2 ]
Yu, Nanze [2 ,3 ]
Diao, Wenqi [4 ]
Yang, Xiaonan [1 ,2 ]
Feng, Yongqiang [1 ,2 ]
Qi, Zuoliang [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Plast Surg Hosp, 33 Badachu Rd, Beijing 100068, Peoples R China
[2] Peking Union Med Coll, 33 Badachu Rd, Beijing 100068, Peoples R China
[3] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Div Plast Surg, Beijing 100068, Peoples R China
[4] Peking Univ, Hosp 3, Dept Resp Med, Beijing 100871, Peoples R China
关键词
Nevus of Ota; Q-switched Alexandrite laser; Q-switched Nd:YAG laser; Clinical efficacy; Complications; ND-YAG LASERS; RUBY-LASER; SELECTIVE PHOTOTHERMOLYSIS; SKIN; NM;
D O I
10.1007/s10103-016-1885-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Although the application of Q-switched lasers on nevus of Ota (OTA) is well demonstrated, debates about clinical option between Q-switched alexandrite laser (QSA) and Q-switched Nd:YAG laser (QSNY) still remain. This systematic review and meta-analysis estimated the overall successful rate of OTA pigment clearance and complication rate of QSA and QSNY and evaluated which laser could produce a better result. English articles evaluating pigment clearance and complications of QSA and/or QSNY on OTA were screened through predetermined inclusion and exclusion criteria and analyzed. The successful rate of pigment clearance and complication rate of QSA and QSNY were respectively calculated using a random-effects or fixed-effects model, depending on the heterogeneity of the included studies. The successful rate and complication rate of QSA and QSNY were compared statistically. Of the 140 articles searched, 13 met inclusion criteria. Totally, 2153 OTA patients treated by QSA and 316 patients treated by QSNY were analyzed. In QSA and QSNY groups, respectively, the successful rate of OTA pigment clearance was 48.3 % (95 % confidence interval (CI) 19.9-76.8 %) and 41 % (95 % CI 9.7-72.2 %), while the complication rate was 8.0 % (95 % CI 3.9-12.2 %) and 13.4 % (95 % CI 7.7-19.0 %). When compared with QSNY, QSA had a significantly higher successful rate (P = 0.017), and a lower complication rate (P = 0.000). According to this review, QSA may surpass QSNY in treatment for OTA as it had a superior successful rate of pigment clearance and a lower complication rate than QSNY did.
引用
收藏
页码:581 / 591
页数:11
相关论文
共 50 条
  • [31] Treatment of persistent Mongolian spots with Q-switched alexandrite laser
    Kagami, Shinji
    Asahina, Akihiko
    Uwajima, Yuta
    Miyamoto, Akie
    Yamada, Daisuke
    Shibata, Sayaka
    Yamamoto, Mizuho
    Masui, Yuri
    Sato, Shinichi
    LASERS IN MEDICAL SCIENCE, 2012, 27 (06) : 1229 - 1232
  • [32] Beneficial Effects of Treatment With Low-Fluence 755-nm Q-Switched Alexandrite Laser for Nevus of Ota
    Wu, Xiaojin
    Wang, Xue
    Shang, Ying
    Xu, Hui
    Zhang, Zhen
    LASERS IN SURGERY AND MEDICINE, 2021, 53 (10) : 1364 - 1369
  • [33] A split-face study: comparison of picosecond alexandrite laser and Q-switched Nd:YAG laser in the treatment of melasma in Asians
    Lee, Mei-Ching
    Lin, Ying-Fang
    Hu, Sindy
    Huang, Yau-Li
    Chang, Shyue-Luen
    Cheng, Chun-Yu
    Chang, Chun-Shin
    LASERS IN MEDICAL SCIENCE, 2018, 33 (08) : 1733 - 1738
  • [34] Clinical use of the Q-switched Nd:YAG laser for the treatment of acquired bilateral nevus of Ota-like macules (ABNOMs) in Koreans
    Suh, DH
    Han, KH
    Chung, JH
    JOURNAL OF DERMATOLOGICAL TREATMENT, 2001, 12 (03) : 163 - 166
  • [35] Beneficial Effects of Early Treatment of Nevus of Ota With Low-Fluence 1,064-nm Q-Switched Nd:YAG Laser
    Seo, Hyun-Min
    Choi, Chong-Won
    Kim, Won-Serk
    DERMATOLOGIC SURGERY, 2015, 41 (01) : 142 - 148
  • [36] Laser transmission through membranes using the Q-switched Nd:YAG laser
    Pay, AD
    Kenealy, JM
    LASERS IN SURGERY AND MEDICINE, 1999, 24 (01) : 48 - 54
  • [37] In vivo trial comparing patients' tolerance of Q-switched alexandrite (QS Alex) and Q-switched neodymium:yttrium-aluminum-garnet (QS Nd:YAG) lasers in the treatment of nevus of Ota
    Chan, HHL
    King, WWK
    Chan, ESY
    Mok, CO
    Ho, WS
    Van Krevel, C
    Lau, WY
    LASERS IN SURGERY AND MEDICINE, 1999, 24 (01) : 24 - 28
  • [38] Treatment of nevus of Ota by Q switched Nd : YAG laser: a histologic and histometric study
    El-Domyati, Moetaz
    Hosam, Wael
    Nasef, Ghada
    Abdel-Aziz, Rasha T. A.
    Raouf, Yousra
    JOURNAL OF EGYPTIAN WOMENS DERMATOLOGICAL SOCIETY, 2019, 16 (03): : 147 - 154
  • [39] Tattoo removal by Q-switched ruby laser (694 nm) and Q-switched Nd:YAG laser (532 and 1064 nm) -: a retrospective study
    Werner, S
    Drosner, M
    Raulin, C
    HAUTARZT, 1999, 50 (03): : 174 - 180