Comparison of clinical efficacy and complications between Q-switched alexandrite laser and Q-switched Nd:YAG laser on nevus of Ota: a systematic review and meta-analysis

被引:16
作者
Yu, Panxi [1 ,2 ]
Yu, Nanze [2 ,3 ]
Diao, Wenqi [4 ]
Yang, Xiaonan [1 ,2 ]
Feng, Yongqiang [1 ,2 ]
Qi, Zuoliang [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Plast Surg Hosp, 33 Badachu Rd, Beijing 100068, Peoples R China
[2] Peking Union Med Coll, 33 Badachu Rd, Beijing 100068, Peoples R China
[3] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Div Plast Surg, Beijing 100068, Peoples R China
[4] Peking Univ, Hosp 3, Dept Resp Med, Beijing 100871, Peoples R China
关键词
Nevus of Ota; Q-switched Alexandrite laser; Q-switched Nd:YAG laser; Clinical efficacy; Complications; ND-YAG LASERS; RUBY-LASER; SELECTIVE PHOTOTHERMOLYSIS; SKIN; NM;
D O I
10.1007/s10103-016-1885-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Although the application of Q-switched lasers on nevus of Ota (OTA) is well demonstrated, debates about clinical option between Q-switched alexandrite laser (QSA) and Q-switched Nd:YAG laser (QSNY) still remain. This systematic review and meta-analysis estimated the overall successful rate of OTA pigment clearance and complication rate of QSA and QSNY and evaluated which laser could produce a better result. English articles evaluating pigment clearance and complications of QSA and/or QSNY on OTA were screened through predetermined inclusion and exclusion criteria and analyzed. The successful rate of pigment clearance and complication rate of QSA and QSNY were respectively calculated using a random-effects or fixed-effects model, depending on the heterogeneity of the included studies. The successful rate and complication rate of QSA and QSNY were compared statistically. Of the 140 articles searched, 13 met inclusion criteria. Totally, 2153 OTA patients treated by QSA and 316 patients treated by QSNY were analyzed. In QSA and QSNY groups, respectively, the successful rate of OTA pigment clearance was 48.3 % (95 % confidence interval (CI) 19.9-76.8 %) and 41 % (95 % CI 9.7-72.2 %), while the complication rate was 8.0 % (95 % CI 3.9-12.2 %) and 13.4 % (95 % CI 7.7-19.0 %). When compared with QSNY, QSA had a significantly higher successful rate (P = 0.017), and a lower complication rate (P = 0.000). According to this review, QSA may surpass QSNY in treatment for OTA as it had a superior successful rate of pigment clearance and a lower complication rate than QSNY did.
引用
收藏
页码:581 / 591
页数:11
相关论文
共 50 条
  • [21] Research on Q-Switched Nd:YAG laser engraving
    Gao, H
    Luo, GX
    Yu, K
    Chen, GN
    LASER TECHNIQUES FOR SURFACE SCIENCE III, 1998, 3272 : 126 - 132
  • [22] Efficacy of the combination of Q-switched Nd:YAG laser and microneedling for melasma
    Karadag Kose, Ozlem
    Borlu, Murat
    JOURNAL OF COSMETIC DERMATOLOGY, 2021, 20 (03) : 769 - 775
  • [23] Treatment of Ota's nevus by Q-switched alexandrite laser: therapeutic outcome in relation to clinical and histopathological findings
    Kang, WH
    Lee, ES
    Choi, GS
    EUROPEAN JOURNAL OF DERMATOLOGY, 1999, 9 (08) : 639 - 643
  • [24] BENEFICIAL EFFECTS OF EARLY TREATMENT OF NEVUS OF OTA WITH 1064-NM Q-SWITCHED ND:YAG LASER
    Kim, Jung-In
    Seo, Hyun-Min
    Jung, Ho Joo
    Nam, Jae-Hui
    Park, Ji-Hye
    Choi, Chong Won
    Lee, Ga-Young
    Kim, Won-Serk
    JOURNAL OF DERMATOLOGY, 2014, 41 : 98 - 98
  • [25] Nevus of Ota on the auricle successfully treated with Q-switched ruby laser
    Yamada-Kanazawa, Saori
    Jinnin, Masatoshi
    Fukushima, Satoshi
    DRUG DISCOVERIES AND THERAPEUTICS, 2022, 16 (05) : 254 - 255
  • [26] A split-face comparison of Q-switched Nd:YAG 1064-nm laser for facial rejuvenation in Nevus of Ota patients
    Cao Yongqian
    Lin Li
    Bi Jianhai
    Huo Ran
    Guo Li
    Wei Hao
    Wang Xining
    Xie Shigang
    Wang Yibing
    Lasers in Medical Science, 2017, 32 : 765 - 769
  • [27] A split-face comparison of Q-switched Nd:YAG 1064-nm laser for facial rejuvenation in Nevus of Ota patients
    Cao Yongqian
    Lin Li
    Bi Jianhai
    Huo Ran
    Guo Li
    Wei Hao
    Wang Xining
    Xie Shigang
    Wang Yibing
    LASERS IN MEDICAL SCIENCE, 2017, 32 (04) : 765 - 769
  • [28] Laser marking of stainless steel with a Q-switched Nd:YAG laser
    Qi, J
    Wang, KL
    Liang, MC
    Zhu, YM
    Fang, MG
    LASER PROCESSING OF MATERIALS AND INDUSTRIAL APPLICATIONS II, 1998, 3550 : 311 - 315
  • [29] Efficacy of the 1064-nm Q-switched Nd:YAG laser in melasma
    Suh, Kee Suck
    Sung, Jae Young
    Roh, Hyo Jin
    Jeon, Young Seung
    Kim, Yang Che
    Kim, Sang Tae
    JOURNAL OF DERMATOLOGICAL TREATMENT, 2011, 22 (04) : 233 - 238
  • [30] Stabilization of quasiperiodic outputs of a Q-Switched Nd:YAG laser
    Kim, CM
    Kye, WH
    Rim, S
    Kim, JM
    Lee, KS
    6TH WORLD MULTICONFERENCE ON SYSTEMICS, CYBERNETICS AND INFORMATICS, VOL VI, PROCEEDINGS: INDUSTRIAL SYSTEMS AND ENGINEERING I, 2002, : 388 - 392