Smooth tactile display in mouse using electro-rheological gel

被引:0
|
作者
Matsuura, K [1 ]
Yakoh, T [1 ]
Aoyama, T [1 ]
Anzai, H [1 ]
Sakurai, K [1 ]
Isobe, K [1 ]
机构
[1] Keio Univ, Fac Sci & Technol, Dept Syst Design Engn, Tokyo 108, Japan
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In recent years, mice have been used widely as one of the important pointing devices of a computer. The mouse which has high performance and multiple functions is required in order to improve the usability of a computer. Some researches which add a tactile display function to a mouse have been done, and mice with the tactile display using a vibrator have been put on the market. However. acoustic noise generated by the vibrator make its user uncomfortable. Then., this article proposed and developed a new tactile display mouse using passive and fail-safe device called ERG (Electro-rheological Gel). First. the characteristics of ERG were measured through some experiments. From the results, it is found that the stiffness of ERG is an electrically controllable characteristic when ERG and electrode is sliding. Then the device was incorporated into the click button of a mouse and evaluated through some identification tests by some human to identify the button's stiffness. In shortly, identification rate was over 90%. Consequently, the developed tactile display can successfully express multi-level of tactile senses. Finally some application of the tactile display also proposed.
引用
收藏
页码:424 / 429
页数:6
相关论文
共 50 条
  • [31] Stress behavior and conductivity of the electro-rheological suspensions
    Tanaka, K
    Ichizawa, K
    Onishi, Y
    Kubono, A
    Akiyama, R
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2002, 16 (17-18): : 2683 - 2689
  • [32] Manipulation terahertz wave with electro-rheological fluid
    Li Jiu-sheng
    Hu Mu-shu
    OPTICS COMMUNICATIONS, 2020, 475
  • [33] Asymptotic estimation for the system of electro-rheological fluids
    Cheng, OY
    ACTA PHYSICA SINICA, 2004, 53 (06) : 1900 - 1902
  • [34] Electro-Rheological Model of HP Indigo ElectroInk
    Forgacs, Peter
    Teishev, Albert
    JOURNAL OF IMAGING SCIENCE AND TECHNOLOGY, 2013, 57 (03)
  • [35] Transfer function identification of an electro-rheological actuator
    Brookfield, DJ
    Dlodlo, ZB
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 1996, 10 (23-24): : 3115 - 3132
  • [36] Regularity Results for Stationary Electro-Rheological Fluids
    Emilio Acerbi
    Giuseppe Mingione
    Archive for Rational Mechanics and Analysis, 2002, 164 : 213 - 259
  • [37] Braking responses of inertia/load by using an electro-rheological (ER) brake
    Tan, K. P.
    Stanway, R.
    Bullough, W. A.
    MECHATRONICS, 2007, 17 (06) : 277 - 289
  • [38] Viscosity of an electro-rheological suspension with internal rotations
    Lemaire, E.
    Lobry, L.
    Pannacci, N.
    Peters, F.
    JOURNAL OF RHEOLOGY, 2008, 52 (03) : 769 - 783
  • [39] ON THE MECHANICAL PROPERTIES OF ELECTRO-RHEOLOGICAL FLUIDS.
    Stevens, N.G.
    Sproston, J.L.
    Stanway, R.
    Journal of Applied Mechanics, Transactions ASME, 1987, 54 (02): : 456 - 458
  • [40] Diglycerol derivatives as a novel electro-rheological fluid
    Nakamura, Naotake
    Kojima, Akiko
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 2007, 465 : 15 - 24