Selective Electrochemical Sensing of Riboflavin Based on Functionalized Multi-Walled Carbon Nanotube/Gold Nanoparticle/Pencil Graphite Electrode

被引:23
作者
Dokur, Ebrar [1 ]
Gorduk, Ozge [1 ]
Sahin, Yucel [1 ]
机构
[1] Yildiz Tech Univ, Dept Chem, Fac Arts & Sci, TR-34210 Istanbul, Turkey
关键词
Riboflavin (RF); multi-walled carbon nanotube (MWCNT); gold nanoparticle (AuNP); cyclic voltammetry (CV); differential pulse voltammetry (DPV); VOLTAMMETRIC DETERMINATION; VITAMIN B-2; PASTE ELECTRODE; ASCORBIC-ACID; FOLIC-ACID; FILM ELECTRODE; ONE-STEP; SENSOR; URINE;
D O I
10.1149/2162-8777/abcdff
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this study; an easy, practical, and selective sensor has been developed for the electrochemical determination of riboflavin. To prepare the modified electrode, the gold nanoparticle was deposited on the pencil graphite electrode (AuNP/PGE) by the method of chronoamperometry at -3.0 V for 30 s in 0.5 M H2SO4 solution containing 10 mM tetrachloroaurate. Functionalized multi-walled carbon nanotube (f-MWCNT) solution was dropped on prepared AuNP/PGE and the functionalized multi-walled carbon nanotube/gold nanoparticle/pencil graphite electrode (f-MWCNT/AuNP/PGE) was prepared for measurements. Characterization studies of the prepared sensor were performed using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), energy-dispersive X-ray spectroscopy (EDX), and X-ray photoelectron spectroscopy (XPS) methods. The surface morphology of the prepared sensor was investigated by field emission scanning electron microscopy (FESEM). Differential pulse voltammetry (DPV) was used to carry out electrochemical measurements in phosphate buffer solution pH 4.0. Limit of detection (LOD) and limit of quantitation (LOQ) values were found to be 0.0352 and 0.118 mu mol l(-1), respectively. The fabricated sensor showed excellent anti-interference ability against ascorbic acid (AA) and glucose (G). The applicability of the constructed sensor to real samples was investigated and good recovery values were achieved. As a result, it has been seen that the modified electrode is applicable in applications of riboflavin determination.
引用
收藏
页数:9
相关论文
共 60 条
[2]  
[Anonymous], 2016, PHYS CHEM COMMUN
[3]   A simple and efficient electrochemical sensor for folic acid determination in human blood plasma based on gold nanoparticles-modified carbon paste electrode [J].
Arvand, Majid ;
Dehsaraei, Mohammad .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (06) :3474-3480
[4]   HPLC DETERMINATION OF RIBOFLAVIN IN EGGS AND DAIRY-PRODUCTS [J].
ASHOOR, SH ;
SEPERICH, GJ ;
MONTE, WC ;
WELTY, J .
JOURNAL OF FOOD SCIENCE, 1983, 48 (01) :92-&
[5]   Voltammetric monitoring of electrochemical reduction of riboflavin using silver solid amalgam electrodes [J].
Bandzuchova, Lenka ;
Selesovska, Renata ;
Navratil, Tomas ;
Chylkova, Jaromira ;
Novotny, Ladislav .
ELECTROCHIMICA ACTA, 2012, 75 :316-324
[6]  
Boslaugh S., 2007, ENCY EPIDEMIOL, V54, P2121
[7]   Biological applications of diamond electrodes; electrochemical studies of riboflavin [J].
Chatterjee, A. ;
Foord, J. S. .
DIAMOND AND RELATED MATERIALS, 2009, 18 (5-8) :899-903
[8]  
D'Souza ES, 2020, ANAL BIOANAL CHEM RE, V7, P461
[9]   Differential Pulse Voltammetric Determination of Folic Acid Using a Poly(Cystine) Modified Pencil Graphite Electrode [J].
Dokur, Ebrar ;
Gorduk, Ozge ;
Sahin, Yucel .
ANALYTICAL LETTERS, 2020, 53 (13) :2060-2078
[10]   Simultaneous spectrophotometric multicomponent determination of folic acid, thiamine, riboflavin, and pyridoxal by using double divisor-ratio spectra derivative-zero crossing method [J].
Ghasemi, J ;
Abbasi, B ;
Niazi, A ;
Nadaf, E ;
Mordai, A .
ANALYTICAL LETTERS, 2004, 37 (12) :2609-2623