Ultra-High Resolution Photon-Counting Detector CT Reconstruction using Spectral Prior Image Constrained Compressed-Sensing (UHR-SPICCS)

被引:14
作者
Rajendran, Kishore [1 ]
Tao, Shengzhen [1 ]
Abdurakhimova, Dilbar [1 ]
Leng, Shuai [1 ]
McCollough, Cynthia [1 ]
机构
[1] Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA
来源
MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING | 2018年 / 10573卷
关键词
Photon-counting detectors; computed tomography; multi-energy; ultra-high resolution; image reconstruction; compressed sensing; prior image constrained compressed sensing; COMPUTED-TOMOGRAPHY; NOISE; PICCS;
D O I
10.1117/12.2294628
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Photon-counting detector based CT (PCD-CT) enables dose efficient high resolution imaging, in addition to providing multi-energy information. This allows better delineation of anatomical structures crucial for several clinical applications ranging from temporal bone imaging to pulmonary nodule visualization. Due to the smaller detector pixel sizes required for high resolution imaging, the PCD-CT images suffer from higher noise levels. The image quality is further degraded in narrow energy bins as a consequence of low photon counts. This limits the potential benefits that high-resolution PCD-CT could offer. Conventional reconstruction techniques such as the filtered back projection (FBP) have poor performance when reconstructing noisy CT projection data. To enable low noise multi-energy reconstructions, we employed a spectral prior image constrained compressed sensing (SPICCS) framework that exploits the spatio-spectral redundancy in the multi-energy acquisitions. We demonstrated noise reduction in narrow energy bins without losing energy-specific attenuation information and spatial resolution. We scanned an anthropomorphic head phantom, and a euthanized pig using our whole-body prototype PCD-CT system in the ultra-high resolution mode at 120 kV. Image reconstructions were performed using SPICCS and compared with conventional FBP. Noise reduction of 18 to 46% was noticed in narrow energy bins corresponding to 25-65 keV and 65-120 keV, while the mean CT number was preserved. Spatial resolution measurement showed similar modulation transfer function (MTF) values between FBP and SPICCS, demonstrating preservation of spatial resolution.
引用
收藏
页数:6
相关论文
共 8 条
[1]   Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets [J].
Chen, Guang-Hong ;
Tang, Jie ;
Leng, Shuai .
MEDICAL PHYSICS, 2008, 35 (02) :660-663
[2]   Human Imaging With Photon Counting-Based Computed Tomography at Clinical Dose Levels: Contrast-to-Noise Ratio and Cadaver Studies [J].
Gutjahr, Ralf ;
Halaweish, Ahmed F. ;
Yu, Zhicong ;
Leng, Shuai ;
Yu, Lifeng ;
Li, Zhoubo ;
Jorgensen, Steven M. ;
Ritman, Erik L. ;
Kappler, Steffen ;
McCollough, Cynthia H. .
INVESTIGATIVE RADIOLOGY, 2016, 51 (07) :421-429
[3]   Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system [J].
Leng, Shuai ;
Yu, Zhicong ;
Halaweish, Ahmed ;
Kappler, Steffen ;
Hahn, Katharina ;
Henning, Andre ;
Li, Zhoubo ;
Lane, John ;
Levin, David L. ;
Jorgensen, Steven ;
Ritman, Erik ;
McCollough, Cynthia .
JOURNAL OF MEDICAL IMAGING, 2016, 3 (04)
[4]   Noise reduction in spectral CT: Reducing dose and breaking the trade-off between image noise and energy bin selection [J].
Leng, Shuai ;
Yu, Lifeng ;
Wang, Jia ;
Fletcher, Joel G. ;
Mistretta, Charles A. ;
McCollough, Cynthia H. .
MEDICAL PHYSICS, 2011, 38 (09) :4946-4957
[5]  
S. Leng, 2017, P SPIE INT SOC OPT E
[6]   Spectral prior image constrained compressed sensing (spectral PICCS) for photon-counting computed tomography [J].
Yu, Zhicong ;
Leng, Shuai ;
Li, Zhoubo ;
McCollough, Cynthia H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (18) :6707-6732
[7]   How Low Can We Go in Radiation Dose for the Data-Completion Scan on a Research Whole-Body Photon-Counting Computed Tomography System [J].
Yu, Zhicong ;
Leng, Shuai ;
Li, Zhoubo ;
Halaweish, Ahmed F. ;
Kappler, Steffen ;
Ritman, Erik L. ;
McCollough, Cynthia H. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (04) :663-670
[8]   Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array [J].
Yu, Zhicong ;
Leng, Shuai ;
Jorgensen, Steven M. ;
Li, Zhoubo ;
Gutjahr, Ralf ;
Chen, Baiyu ;
Halaweish, Ahmed F. ;
Kappler, Steffen ;
Yu, Lifeng ;
Ritman, Erik L. ;
McCollough, Cynthia H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (04) :1572-1595