摘要
The nanocomposite of graphene-iron oxide-polyvinyl alcohol (PIG) was synthesized via simple one-pot hydrothermal method and was used in the modification of pencil graphite electrode for developing an electrochemical sensor. Graphene (G) and iron oxide-graphene (IG) composites were synthesized for providing a comparative study. The structural properties of the prepared PIG were studied through X-Ray diffraction (XRD) technique, whereas the morphological analysis was conducted through field emission scanning electron microscopy (FESEM) and transmission electron microscopy (TEM) study. The chemical states of elements present in the prepared composite were confirmed using X-ray photoelectron spectroscopy (XPS) and the functional groups present in the composite were investigated through Fourier transform infrared (FTIR) spectroscopy. The existence of iron oxide nanoparticles along with PVA polymer in PIG composite enhances the electroactive area (0.073 cm(2)) and roughness factor (0.186) along with the sensitivity of the material. The square wave voltammetry technique was used for detecting the biomolecule i.e. vitamin C.At optimized condition, the PIG modified electrode shows a high linear range (40 mu M-4100 mu M), low limit of detection (0.234 mu M) and higher sensitivity (1597.03 mu A cm(-2) mM(-1)). The PIG material also provides a good stability towards detection of vitamin C. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:304 / 313
页数:10
相关论文
共 54 条
[1]  
Akyildirim O, 2015, INT J ELECTROCHEM SC, V10, P7743
[2]   Electrochemical detection of nitrite and ascorbic acid at glassy carbon electrodes modified with carbon nano-onions bearing electroactive moieties [J].
Bartolome, Joanne P. ;
Fragoso, Alex .
INORGANICA CHIMICA ACTA, 2017, 468 :223-231
[3]   Ferroferric Oxide/Multiwalled Carbon Nanotube vs Polyaniline/Ferroferric Oxide/Multiwalled Carbon Nanotube Multiheterostructures for Highly Effective Microwave Absorption [J].
Cao, Mao-Sheng ;
Yang, Jian ;
Song, Wei-Li ;
Zhang, De-Qing ;
Wen, Bo ;
Jin, Hai-Bo ;
Hou, Zhi-Ling ;
Yuan, Jie .
ACS APPLIED MATERIALS & INTERFACES, 2012, 4 (12) :6949-6956
[4]   A nanoclay-based magnetic/fluorometric bimodal strategy for ascorbic acid detection [J].
Chen, Xi ;
Xu, Yang ;
Li, Huanrong ;
Liu, Binyuan .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 246 :344-351
[5]   Enhanced electromagnetic interference shielding efficiency of polystyrene/graphene composites with magnetic Fe3O4 nanoparticles [J].
Chen, Yu ;
Wang, Yongli ;
Zhang, Hao-Bin ;
Li, Xiaofeng ;
Gui, Chen-Xi ;
Yu, Zhong-Zhen .
CARBON, 2015, 82 :67-76
[6]   Electrochemical detection of uric acid and ascorbic acid: Application in serum [J].
Choukairi, M. ;
Bouchta, D. ;
Bounab, L. ;
Ben Atyah, M. ;
Elkhamlichi, R. ;
Chaouket, F. ;
Raissouni, I. ;
Rodriguez, I. N. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 758 :117-124
[7]   Simultaneous removal of NOX and SO2 with H2O2 over Fe based catalysts at low temperature [J].
Ding, Jie ;
Zhong, Qin ;
Zhang, Shule .
RSC ADVANCES, 2014, 4 (11) :5394-5398
[8]   Selective Synthesis of Fe2O3 and Fe3O4 Nanowires Via a Single Precursor: A General Method for Metal Oxide Nanowires [J].
Du, Ning ;
Xu, Yanfang ;
Zhang, Hui ;
Zhai, Chuanxin ;
Yang, Deren .
NANOSCALE RESEARCH LETTERS, 2010, 5 (08) :1295-1300
[9]   A highly stable and sensitive GO-XDA-Mn2O3 electrochemical sensor for simultaneous electrooxidation of paracetamol and ascorbic acid [J].
Ejaz, Ammara ;
Jeon, Seungwon .
ELECTROCHIMICA ACTA, 2017, 245 :742-751
[10]   Magnetic Fe3O4-graphene composites as targeted drug nanocarriers for pH-activated release [J].
Fan, Xiujuan ;
Jiao, Guozheng ;
Zhao, Wei ;
Jin, Pengfei ;
Li, Xin .
NANOSCALE, 2013, 5 (03) :1143-1152