Study of particle size effects on an optical fiber sensor response examined with Monte Carlo simulation

被引:35
作者
Tran, Nguyen T.
Campbell, Chris G.
Shi, Frank G.
机构
[1] Univ Calif Irvine, Optoelect Packaging & Mat Lab, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Henry Samueli Sch Engn, Irvine, CA 92697 USA
[3] Lawrence Livermore Natl Lab, Water Guidance & Monitoring Grp, Environm Protect Dept, Livermore, CA 94550 USA
关键词
D O I
10.1364/AO.45.007557
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical fiber sensors based on the total light transmittance are widely used to measure the volume fraction of particles in suspensions. However, the sensor response depends not only on the volume fraction but also on the particle size. The particle size effect is studied for a sensor configuration consisting of two linear arrays of fibers on each of two blocks: the emitting and receiving blocks. These two linear arrays are arranged with three adjacent fibers (one fiber on the first array, two fibers on the second array) forming a perfect triangle. The almost superimposition of the calculated sensor response versus the extinction factor for different particle sizes allows for the application of single-curve models. Two single-curve models that describe the sensor response for all particle sizes ranging from 36 to 200 mu m are proposed. The models are validated by Monte Carlo simulation for different particle sizes and are valid within a detectable volume fraction. The single-curve models proposed provide an easier approach to creating a database for sensor calibration for suspended sediment concentration measurements. (c) 2006 Optical Society of America
引用
收藏
页码:7557 / 7566
页数:10
相关论文
共 25 条
[1]   Field and laboratory studies on the effect of particle size and composition on optical backscattering measurements in hydrothermal plumes [J].
Baker, ET ;
Tennant, DA ;
Feely, RA ;
Lebon, GT ;
Walker, SL .
DEEP-SEA RESEARCH PART I-OCEANOGRAPHIC RESEARCH PAPERS, 2001, 48 (02) :593-604
[2]   THE EFFECT OF PARTICLE-SIZE ON THE LIGHT ATTENUATION COEFFICIENT OF NATURAL SUSPENSIONS [J].
BAKER, ET ;
LAVELLE, JW .
JOURNAL OF GEOPHYSICAL RESEARCH-OCEANS, 1984, 89 (NC5) :8197-8203
[3]   Monte Carlo calculation of backscattered light intensity by suspension: Comparison with experimental data [J].
Bergougnoux, L ;
MisguichRipault, J ;
Firpo, JL ;
Andre, J .
APPLIED OPTICS, 1996, 35 (10) :1735-1741
[4]   High concentration suspended sediment measurements using a continuous fiber optic in-stream transmissometer [J].
Campbell, CG ;
Laycak, DT ;
Hoppes, W ;
Tran, NT ;
Shi, FG .
JOURNAL OF HYDROLOGY, 2005, 311 (1-4) :244-253
[5]  
CASHWELL ED, 1959, PRACTICAL MANUAL MON
[6]   LABORATORY AND FIELD ASSESSMENT OF AN INFRARED TURBIDITY PROBE AND ITS RESPONSE TO PARTICLE-SIZE AND VARIATION IN SUSPENDED SEDIMENT CONCENTRATION [J].
CLIFFORD, NJ ;
RICHARDS, KS ;
BROWN, RA ;
LANE, SN .
HYDROLOGICAL SCIENCES JOURNAL-JOURNAL DES SCIENCES HYDROLOGIQUES, 1995, 40 (06) :771-791
[7]   Turbidity, suspended sediment, and water clarity: A review [J].
Davies-Colley, RJ ;
Smith, DG .
JOURNAL OF THE AMERICAN WATER RESOURCES ASSOCIATION, 2001, 37 (05) :1085-1101
[8]   AN ASSOCIATION BETWEEN AIR-POLLUTION AND MORTALITY IN 6 UNITED-STATES CITIES [J].
DOCKERY, DW ;
POPE, CA ;
XU, XP ;
SPENGLER, JD ;
WARE, JH ;
FAY, ME ;
FERRIS, BG ;
SPEIZER, FE .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (24) :1753-1759
[9]   Concentration profiles in a gravity chute conveyor by optical tomography measurement [J].
Green, RG ;
Rahim, RA ;
Evans, K ;
Dickin, FJ ;
Naylor, BD ;
Pridmore, TP .
POWDER TECHNOLOGY, 1998, 95 (01) :49-54
[10]   MEASUREMENT OF DISTRIBUTION OF SOLIDS CONCENTRATION ON HIGH-DENSITY GAS-SOLIDS FLOW USING AN OPTICAL-FIBER PROBE SYSTEM [J].
HONG, J ;
TOMITA, Y .
POWDER TECHNOLOGY, 1995, 83 (01) :85-91