Antibacterial, Antifungal and Ecotoxic Effects of Ammonium and Imidazolium Ionic Liquids Synthesized in Microwaves

被引:9
作者
Fojtaskova, Jana [1 ,2 ]
Koutnik, Ivan [1 ,2 ]
Vrablova, Martina [1 ]
Sezimova, Hana [3 ]
Maxa, Milan [4 ]
Obalova, Lucie [1 ]
Panek, Petr [1 ,2 ]
机构
[1] VSB Tech Univ Ostrava, Inst Environm Technol, 17 Listopadu 15, Ostrava 70800, Czech Republic
[2] VSB Tech Univ Ostrava, Fac Mat Sci & Technol, 17 Listopadu 15, Ostrava 70800, Czech Republic
[3] Univ Ostrava, Fac Sci, Dept Biol & Ecol, Chittussiho 10, Ostrava 71000, Czech Republic
[4] TECHEM CZ Ltd, Ondrickova 1300-48, Prague 13005 3, Czech Republic
关键词
ionic liquid; microwave synthesis; imidazolium; quaternary ammonium salt; ecotoxicity; VIBRIO-FISCHERI; ACUTE TOXICITY; CHLORIDE; WATER; DISINFECTANTS; LUMINESCENCE; SURFACTANTS; EFFICACY; REMOVAL;
D O I
10.3390/molecules25215181
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Ionic liquids are increasingly used for their superior properties. Four water-immiscible ionic liquids (butyltriethylammonium bis(trifluoromethylsulfonyl)imide, octyltriethylammonium bis(trifluoromethylsulfonyl)imide, dodecyltriethylammonium bis(trifluoromethylsulfonyl)imide, butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide) and their water miscible precursors (bromides) were synthesized in a microwave reactor and by conventional heating. The best conditions for microwave-assisted synthesis concerning the yield and the purity of the product are proposed. The heating in the microwave reactor significantly shortened the reaction time. Biocide and ecotoxic effects of synthesized ionic liquids and their precursors were investigated. All tested compounds had at least a little effect on the growth or living of microorganisms (bacteria or mold). The precursor dodecyltriethylammonium bromide was found to be the strongest biocide, but posed a risk to the aquatic environment due to its relatively high EC50 value in the test with Vibrio fischeri. We assumed that apart from the alkyl chain length, the solubility in water, duration of action, or type of anion can influence the final biocide and ecotoxic effect.
引用
收藏
页数:13
相关论文
共 57 条
[1]   Extraction of halogenated hydrocarbons using hydrophobic ionic liquids [J].
AlSaleem, Saleem S. ;
Zahid, Waleed M. ;
Alnashef, Inas M. ;
Haider, Husnain .
SEPARATION AND PURIFICATION TECHNOLOGY, 2017, 184 :231-239
[2]   Design of ionic liquids: an ecotoxicity (Vibrio fischeri) discrimination approach [J].
Alvarez-Guerra, Manuel ;
Irabien, Angel .
GREEN CHEMISTRY, 2011, 13 (06) :1507-1516
[3]  
[Anonymous], 2003, GRAPHPAD PRISM MANUA
[4]   Phosphonium ionic liquids: design, synthesis and evaluation of biodegradability [J].
Atefi, Farzad ;
Teresa Garcia, M. ;
Singer, Robert D. ;
Scammells, Peter J. .
GREEN CHEMISTRY, 2009, 11 (10) :1595-1604
[5]   A microwave assisted one pot synthesis of novel ammonium based dicationic ionic liquids [J].
Bhatt, Darshak R. ;
Maheria, Kalpana C. ;
Parikh, Jigisha K. .
RSC ADVANCES, 2015, 5 (16) :12139-12143
[6]   Treatment of energetic material contaminated wastewater using ionic liquids [J].
Bhosale, Vikas K. ;
Patil, Nitin V. ;
Kulkarni, Prashant S. .
RSC ADVANCES, 2015, 5 (26) :20503-20510
[7]   Ionic liquids: Innovative fluids for chemical processing [J].
Brennecke, JF ;
Maginn, EJ .
AICHE JOURNAL, 2001, 47 (11) :2384-2389
[8]   A brief overview of the potential environmental hazards of ionic liquids [J].
Bubalo, Marina Cvjetko ;
Radosevic, Kristina ;
Redovnikovic, Ivana Radojcic ;
Halambek, Jasna ;
Srcek, Visnja Gaurina .
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2014, 99 :1-12
[9]   In situ ionic liquid dispersive liquid-liquid microextraction coupled to gas chromatography-mass spectrometry for the determination of organophosphorus pesticides [J].
Cacho, J., I ;
Campillo, N. ;
Vinas, P. ;
Hernandez-Cordoba, M. .
JOURNAL OF CHROMATOGRAPHY A, 2018, 1559 :95-101
[10]   Using machine learning and quantum chemistry descriptors to predict the toxicity of ionic liquids [J].
Cao, Lingdi ;
Zhu, Peng ;
Zhao, Yongsheng ;
Zhao, Jihong .
JOURNAL OF HAZARDOUS MATERIALS, 2018, 352 :17-26