On the acoustic fountain types and flow induced with focused ultrasound

被引:7
|
作者
Kim, Gun [1 ,2 ,3 ]
Cheng, Shyuan [4 ]
Hong, Liu [4 ]
Kim, Jin-Tae [4 ]
Li, King C. [2 ,3 ,5 ]
Chamorro, Leonardo P. [4 ,6 ,7 ,8 ]
机构
[1] Ulsan Natl Inst Sci & Technol UNIST, Sch Urban & Environm Engn, Ulsan 44919, South Korea
[2] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
[3] Univ Illinois, Carle Illinois Coll Med, Urbana, IL 61801 USA
[4] Univ Illinois, Mech Sci & Engn, Urbana, IL 61801 USA
[5] Univ Illinois, Bioengn, Urbana, IL 61801 USA
[6] Univ Illinois, Civil & Environm Engn, Urbana, IL 61801 USA
[7] Univ Illinois, Aerosp Engn, Urbana, IL 61801 USA
[8] Univ Illinois, Geol, Urbana, IL 61801 USA
关键词
jets; RADIATION FORCE; VORTICES;
D O I
10.1017/jfm.2020.1012
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Laboratory experiments are conducted to investigate the mechanism controlling the formation of stable and unstable acoustic fountains at the free surface of a quiescent body of water. Fountains are induced by focused ultrasonic, a new modality that allows for better spatiotemporal control of water flow. Particle image velocimetry was used to characterize the induced flow field in the vicinity of the ultrasonic focal spot. We used two types of ultrasonic transducers with distinct wave frequencies. We examined three fountain formation regimes by varying the pressure level of the transducers, namely weak, intermediate (stable) and highly forced fountains (explosive). Between different regimes, the fountain height underwent a step-change in response to the increase in acoustic pressure. A force estimation obtained from the flow field shows that the magnitude of axial momentum flux is orders of magnitude lower than that of gravity and surface tension, indicating that the dominant driving force for the fountain generation is the acoustic radiation force (Nightingale et al., Ultrasound Med. Biol., vol. 28, 2002, pp. 227-235). We propose a simple model to estimate the shape of a stable fountain; it accounts for the applied acoustic pressure, gravity, surface tension and axial momentum. The model neglects viscous force, which precludes capturing the intermediate fountain surface curvature. However, the model successfully predicts the geometry of the weak and intermediate fountains.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Characterization of focused-ultrasound-induced acoustic streaming
    Slama, R. Ben Haj
    Gilles, B.
    Ben Chiekh, M.
    Bera, J. C.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2019, 101 : 37 - 47
  • [2] ACOUSTIC VISUALIZATION OF TRANSIENT INHOMOGENEITIES INDUCED BY INTENSE FOCUSED ULTRASOUND IN LUCITE
    OKUYAMA, D
    FRY, WJ
    FRY, FJ
    LEICHNER, GH
    KELLY, E
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1966, 39 (06): : 1236 - &
  • [3] Acoustic Streaming Excited by Focused Ultrasound
    Zhvania, I. A.
    Konopatskaya, I. I.
    Mironov, M. A.
    Pyatakov, P. A.
    ACOUSTICAL PHYSICS, 2021, 67 (03) : 245 - 249
  • [4] Acoustic Streaming Excited by Focused Ultrasound
    I. A. Zhvania
    I. I. Konopatskaya
    M. A. Mironov
    P. A. Pyatakov
    Acoustical Physics, 2021, 67 : 245 - 249
  • [5] Acoustic radiation force and streaming induced by focused nonlinear ultrasound in a dissipative medium
    Rudenko, OV
    Sarvazyan, AP
    Emelianov, SY
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1996, 99 (05): : 2791 - 2798
  • [6] OPTIMUM ACOUSTIC FREQUENCY FOR FOCUSED ULTRASOUND SURGERY
    HILL, CR
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (03): : 271 - 277
  • [7] Focused ultrasound setup for the study of acoustic radiation force induced biological effects in cells
    Chandrasekaran, Sri Nivas
    Holm, Sverre
    Prieur, Fabrice
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [8] Acoustic streaming effect on flow and heat transfer in porous tissue during exposure to focused ultrasound
    Wessapan, Teerapot
    Rattanadecho, Phadungsak
    CASE STUDIES IN THERMAL ENGINEERING, 2020, 21
  • [9] Enhancement of acoustic streaming induced flow on a focused surface acoustic wave device: Implications for biosensing and microfluidics
    Singh, Reetu
    Sankaranarayanan, Subramanian K. R. S.
    Bhethanabotla, Venkat R.
    JOURNAL OF APPLIED PHYSICS, 2010, 107 (02)
  • [10] Pitfalls in acoustic transducer modeling for focused ultrasound (FUS)
    Pasquinelli, C.
    Montanaro, H.
    Neufeld, E.
    Poni, R.
    Kuster, N.
    Thielscher, A.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 (05) : 501 - 501