A Measure of Acoustic Noise Generated From Transcranial Magnetic Stimulation Coils

被引:26
作者
Dhamne, Sameer C. [1 ]
Kothare, Raveena S. [1 ]
Yu, Camilla [1 ]
Hsieh, Tsung-Hsun [1 ,2 ]
Anastasio, Elana M. [3 ]
Oberman, Lindsay [3 ]
Pascual-Leone, Alvaro [3 ,4 ]
Rotenberg, Alexander [1 ,3 ]
机构
[1] Harvard Univ, Sch Med, Boston Childrens Hosp, Dept Neurol, Boston, MA 02115 USA
[2] Taipei Med Univ, Grad Inst Neural Regenerat Med, Taipei, Taiwan
[3] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Berenson Allen Ctr Noninvas Brain Stimulat, Boston, MA 02215 USA
[4] Univ Autonoma Barcelona, Inst Univ Neurorehabil Guttmann, Badalona, Spain
关键词
Acoustic noise; Sound pressure levels; Transcranial magnetic stimulation;
D O I
10.1016/j.brs.2014.01.056
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The intensity of sound emanating from the discharge of magnetic coils used in repetitive transcranial magnetic stimulation (rTMS) can potentially cause acoustic trauma. Per Occupational Safety and Health Administration (OSHA) standards for safety of noise exposure, hearing protection is recommended beyond restricted levels of noise and time limits. We measured the sound pressure levels (SPLs) from four rTMS coils with the goal of assessing if the acoustic artifact levels are of sufficient amplitude to warrant protection from acoustic trauma per OSHA standards. We studied the SPLs at two frequencies (5 and 10 Hz), three machine outputs (MO) (60, 80 and 100%), and two distances from the coil (5 and 10 cm). We found that the SPLs were louder at closer proximity from the coil and directly dependent on the MO. We also found that in all studied conditions, SPLs were lower than the OSHA permissible thresholds for short (< 15 min) acoustic exposure, but at extremes of use, may generate sufficient noise to warrant ear protection with prolonged (> 8 h) exposure. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:432 / 434
页数:3
相关论文
共 5 条
  • [1] ANALYSIS OF THE COIL GENERATED IMPULSE NOISE IN EXTRACRANIAL MAGNETIC STIMULATION
    COUNTER, SA
    BORG, E
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1992, 85 (04): : 280 - 288
  • [2] NO EVIDENCE OF HEARING-LOSS IN HUMANS DUE TO TRANSCRANIAL MAGNETIC STIMULATION
    PASCUALLEONE, A
    COHEN, LG
    SHOTLAND, LI
    DANG, N
    PIKUS, A
    WASSERMANN, EM
    BRASILNETO, JP
    VALLSSOLE, J
    HALLETT, M
    [J]. NEUROLOGY, 1992, 42 (03) : 647 - 651
  • [3] Safety, ethical considerations, and application guidelines for the use of transcranial magnetic stimulation in clinical practice and research
    Rossi, Simone
    Hallett, Mark
    Rossini, Paolo M.
    Pascual-Leone, Alvaro
    Avanzini, Giuliano
    Bestmann, Sven
    Berardelli, Alfredo
    Brewer, Carmen
    Canli, Turhan
    Cantello, Roberto
    Chen, Robert
    Classen, Joseph
    Demitrack, Mark
    Di Lazzaro, Vincenzo
    Epstein, Charles M.
    George, Mark S.
    Fregni, Felipe
    Ilmoniemi, Risto
    Jalinous, Reza
    Karp, Barbara
    Lefaucheur, Jean-Pascal
    Lisanby, Sarah
    Meunier, Sabine
    Miniussi, Carlo
    Miranda, Pedro
    Padberg, Frank
    Paulus, Walter
    Peterchev, Angel
    Porteri, Corinna
    Provost, Miriam
    Quartarone, Angelo
    Rotenberg, Alexander
    Rothwell, John
    Ruohonen, Jarmo
    Siebner, Hartwig
    Thut, Gregor
    Valls-Sole, Josep
    Walsh, Vincent
    Ugawa, Yoshikatzu
    Zangen, Abraham
    Ziemann, Ulf
    [J]. CLINICAL NEUROPHYSIOLOGY, 2009, 120 (12) : 2008 - 2039
  • [4] Repetitive transcranial magnetic stimulation: Hearing safety considerations
    Tringali, Stephane
    Perrot, Xavier
    Collet, Lionel
    Moulin, Annie
    [J]. BRAIN STIMULATION, 2012, 5 (03) : 354 - 363
  • [5] Transcranial magnetic stimulation of deep brain regions: evidence for efficacy of the H-coil
    Zangen, A
    Roth, Y
    Voller, B
    Hallett, M
    [J]. CLINICAL NEUROPHYSIOLOGY, 2005, 116 (04) : 775 - 779